Introduction

EverPlex 4CQ, a real time color Quad and 4 channel auto switcher, is the best 
choice for multiple monitoring and recording.

The superior video quality is achieved by adopting the advance multi-media 
technology.  The picture of Quad display is sharp and clear because Everplex 
4CQ is featured with CCIR601 full resolution and 16 million colors.

Main Features:

‰

 

Real-time Quad display.

‰

 

High Resolution 720 x 576 (PAL), 720 x 480 (NTSC).

‰

 

16 million colors.

‰

 

Up to 4 camera inputs and quad display.

‰

 

Video loss detection.

‰

 

Different border colors indicate page selection.

‰

 

Independent brightness, contrast, color and tint adjustments for every
channel.

‰

 

Built-in timer and and title generator.

‰

 

Alarm input with built-in buzzer.

‰

 

Programmable Quad and 4 channel auto switcher outputs.

‰

 

Playback Zoom and Freeze function.

‰

 

RS232 Remote Control.

‰

 

User-friendly front panel design.

Содержание EP4CQ

Страница 1: ...Plex 4CQ USER S MANUAL Set Seq NEXT P DEFAULT Freeze EverPlex 4CQ Real Time Color Quad Processor High Resolution Broadcast Quality Playback Zoom Function RS232 Remote Control Connect Up To 4 Cameras Ver 1 0 ...

Страница 2: ...nel 8 1 6 4 Set the camera titles 8 1 6 5 Set sequential switching parameters 8 1 6 6 Set alarm parameters 9 Chapter II Back Panel Connection 10 1 BNC Connectors 10 1 1 Monitor 10 1 2 VCR out 10 1 3 VCR In 10 1 4 Video input 10 2 Alarm Connectors DB 15 10 2 1 Alarm out 11 2 1 1 Normally open connection 11 2 1 2 Normally closed connection 11 2 2 Alarm in and alrm reset 12 2 2 1 Alarm in 12 2 2 2 Al...

Страница 3: ...to make changes to the product specifications and documentation without notice All the components of the products including accessories components and outlook are based on the agreements if each deals to satisfy all kinds of users Meanwhile please be advised that every step of operation must follow the instruction of this manual to keep EverPlex 4CQ working under the best condition Please notice t...

Страница 4: ...from the outlet before cleansing Do not use liquid cleaners or aerosol cleaners Use a damp cloth to clean it 5 Overload Do not overload outlets and extension cords as this may result in a fire or electric shock 6 Power cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them paying particular attention to cords ...

Страница 5: ...ution and 16 million colors Main Features Real time Quad display High Resolution 720 x 576 PAL 720 x 480 NTSC 16 million colors Up to 4 camera inputs and quad display Video loss detection Different border colors indicate page selection Independent brightness contrast color and tint adjustments for every channel Built in timer and and title generator Alarm input with built in buzzer Programmable Qu...

Страница 6: ...utput x 2 1V p p 75 ohm Title Up to 6 characters Timer Built in real time clock Alarm input 4 alarm inputs and 1 alarm reset input Alarm output 2 Alarm Out 1 Normally Open 1 Normally Closed Dimension 239 x 166 x 55 mm Power source AC 24V or DC 12V Power consumption 17W max ...

Страница 7: ...f freezing status 1 4 Sequential Switching Press SEQ key will enter the auto sequential switching mode the switching sequence is programmed in SET function It can be displayed live quad and full screen sequentially on the main monitor according to the programmed switching sequence Press the SEQ key again to exit the auto sequential mode and stay the last screen display 1 5 VCR Play Back Press PLAY...

Страница 8: ... records Page 3 Set the brightness contrast color and tint for each camera Page 4 Change the title name of each camera Page 5 Program the sequential switching sequence and switching hold time Set the screen refresh mode Page 6 Set the alarm sensor type alarm hold time buzzer on off and Security The following keys are re defined in setting mode Definition under the keypad NEXT P Press NEXT P to go ...

Страница 9: ...to 99 MM Month data from 01 to 12 DD Day data from 01 to 31 TIME data format is HH MM SS where HH Hour data from 00 to 23 MM Minute data from 00 to 59 SS Second data from 00 to 59 VERSION shows current firmware version 1 6 2 Alarm Records ALARM RECORDS C A DATE TIME 3 S 1997 03 24 10 00 00 The Alarm Record format is C A DATE TIME C the channel number from 1 to 4 which invokes the alarm A Alarm typ...

Страница 10: ...camera titles Camera Title Setup CH1 CH1 CH2 CH2 CH3 CH3 CH4 CH4 CH1 CH4 to turn each channel ON or OFF in the sequential switching QUAD to turn QUAD display ON or OFF in the sequential switching SWITCH TIME The time period to switch for each switching item REFRESH MODE To set the screen refresh by FRAME or by FIELD 1 6 5 Set sequential switching parameters Sequential Switch Menu CH1 ON CH2 ON CH3...

Страница 11: ... N C normally closed open will invoke alarm closed means to short the alarm signal line to the ground ALARM RESET IN To set alarm reset input type as N O or N C BUZZER Turn the buzzer ON OFF KEY LOCK Turn the KEY LOCK function ON or OFF when key lock is turned on 1 All keys except SET key are locked 2 KEY LOCK stays ON until we turn it OFF by pressing the SET key ALARM HOLD TIME It is the time per...

Страница 12: ...e quad video output of live video is obtained from this connector 1 3 VCR IN Connect this input port to the VIDEO OUT of VCR 1 4 VIDEO INPUT Connect camera video out to this connector by a 75 ohm coaxial cable 2 Alarm Connectors DB 15 1 8 9 15 PIN NAME PIN NAME 1 Alarm Out Common contact 9 Alarm Out Normally Open 2 Alarm Out Normally Closed 10 TXD 3 Alarm Reset 11 RXD 4 GROUND 5 ALARM IN 4 6 ALARM...

Страница 13: ...e two ways to do the alarm out connection 2 1 1 Normally Open Connection use pin 1 and 9 8 2 1 15 9 COIL EverPlex 4CQ Alarm out RELAY 2 1 2 Normally Closed Connection use pin 1 and 2 8 2 1 15 9 COIL EverPlex 4CQ Alarm out RELAY ...

Страница 14: ... EverPlex 4CQ ALARM RESET ALARM CIRCUIT 2 2 1 ALARM IN There are four alarm inputs for each camera When any alarm signal happens the machine will do the following 1 Switch to the full screen display of this channel 2 Blink the channel ID with alarm message 3 Turn on the buzzer if the buzzer setting is on When many alarms come up in the alarming status the monitor screen will switch to quad display...

Страница 15: ...t is selected as Normally Closed input then the input is shorted to the ground normally Furthermore it is opened when an alarm reset signal comes in If it is selected as Normally Open input then the input is opened normally Also it is shorted to the ground when an alarm reset signal comes in 3 RS232 Connection EverPlex 4CQ may be controlled by a computer or a terminal via the standard 9 pin D sub ...

Страница 16: ...mputer or a terminal can be used to control the EverPlex 4CQ by sending two character ASCII command through RS232 connector These ASCII commands are started with K or k There are 9 ASCII commands mapped to the 9 keypads in the front panel and 1 additional commands to reset the EverPlex 4CQ to the QUAD display state These 10 ASCII commands are show as below EverPlex 4CQ Remote Control Command Table...

Страница 17: ...e ASCII characters followed carriage return and line feed they are The first character is the leading code The second character is the alarm type S indicates a sensor alarm V indicates a video loss The third character is the channel number having the alarm 1 4 The fourth byte is the carriage return code 0DH The fifth byte is the line feed code 0AH ...

Страница 18: ...ve San Marino CA 91108 U S A TEL 1 626 844 8888 FAX 1 626 844 8838 Toll free 1 888 383 6287 or 1 888 EV FOCUS Hong Kong Office Room 0 10 F Block 3 Camelpaint Building 60 Hoi Yuen Road Kwun Tong Kowloon Hong Kong Tel 852 27589877 Fax 852 27589056 European Office Albert Einstein Strasse 1 D 46446 Emmerich Germany TEL 49 2822 9394 0 FAX 49 2822 939495 P N M4CQG0020A ...