65
HD Full:
Figure 4-15 Alarm & Event Menu – Event - HD Full
Log:
Check box to record events in the log.
Buzzer:
Check box to enable the buzzer when hard drive is full (recommended if the Record Overwrite
function is disabled. See Section 5.4.1).
Email Notify:
Check box to enable email notification when HD is full. Email operation requires that valid
email settings have been entered in the Network Setting/Email setup screen.
Network Alarm:
Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Alarm Output:
This will transmit a signal through the alarm output. It can be set to either “
NONE
” (not
active),“
1
”(active), “
2
”(active), “
3
”(active) or
“4
” (active).
Output Type:
Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses the “
Enter
” key or resets the alarm
remotely.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then continues for the set time duration.
Timeout Duration:
The amount of time the alarm condition continues when the HD is full. Duration
selectable from 1 to 150
seconds.