background image

 

14

 

EverFocus Electronics Corp.

 

 

Head Office: 

12F, No.79 Sec. 1 Shin-Tai Wu Road, 

Hsi-Chih, Taipei, Taiwan 

TEL: +886-2-26982334 

FAX: +886-2-26982380 

www.everfocus.com.tw 

 

USA L.A. Office: 

1801 Highland Ave. Unit A 

Duarte, CA 91010, U.S.A. 

TEL: +1-626-844-8888 

FAX: +1-626-844-8838 

www.everfocus.com 

 

USA N.Y. Office: 

415 Oser Avenue Unit S 

Hauppauge, NY 11788 

TEL: 631-436-5070   

FAX: 631-436-5027 

www.everfocus.com

 

 

 

 

Your EverFocus product is designed and 

manufactured with high quality materials and 

components which can be recycled and 

reused. 

This symbol means that electrical and 

electronic equipment, at their end-of-life, 

should be disposed of

 

separately from your 

household waste. 

Please, dispose of this equipment at your 

local community waste collection/recycling 

centre. 

In the European Union there are separate 

collection systems for used electrical and 

electronic product. 

Please, help us to conserve the environment 

we live in!

 

Ihr EverFocus Produkt wurde entwickelt und 

hergestellt mit qualitativ hochwertigen 

Materialien und Komponenten, die recycelt 

und wieder verwendet werden können. 

Dieses Symbol bedeutet, dass elektrische und 

elektronische Geräte am Ende ihrer 

Nutzungsdauer vom Hausmüll getrennt 

entsorgt werden sollen. 

Bitte entsorgen Sie dieses Gerät bei Ihrer 

örtlichen kommunalen Sammelstelle oder im 

Recycling Centre. 

Helfen Sie uns bitte, die Umwelt zu erhalten, in 

der wir leben

P/N: MEHDG00910_Ver.C 

Europe Office: 

Albert-Einstein-Strasse 1 

D-46446 Emmerich, Germany 

TEL: 49-2822-9394-0

   

www.everfocus.de 

 

China Office: 

Room 609, Technology Trade Building, 
Shangdi Information Industry Base, Haidian 
District, Beijing,China 10085 
TEL: +86-10-62973336/37/38/39 

FAX: +86-10-62971423 

www.everfocus.com.cn 

 

Japan Office: 

1809 WBG MARIBU East 18F, 

2-6 Nakase.Mihama-ku. 

Chiba city 261-7118, Japan 

TEL: +81-43-212-8188 

FAX: +81-43-297-0081   

www.everfocus.com 

 

 

Содержание EHD525/EX-2

Страница 1: ...er audio speakers since the magnetic fields generate from above devices will distort the video images 2 Never disassemble the camera nor put impurities in it Disassembly or impurities may result in trouble or fire 3 Never face the camera toward the sun Direct sunlight or severe ray may cause fatal damage to sensor and internal circuit 4 Keep the power cord away from water and liquid Touching the w...

Страница 2: ...emely EHD series are unquestionably one of the world s toughest cameras and is your best choice for vandal resistance EHD525EX is designed with True Day Night function that allows removable Auto IR Cut and an enhanced B W sensitivity while turning the image from color to B W FEATURES z 560 TVL of horizontal resolution z 1 3 Sony ExView CCD with low light sensitivity of 0 1 lux F 1 2 z Revolutionar...

Страница 3: ...TVL Sensitivity 0 1Lux F 1 2 S N Ratio Over 50dB AGC off Electronic Shutter 1 50 1 60 1 100 000 Lens Type Vari focal lens Auto Iris f 2 9 10mm F 1 2 f 3 6 9mm f 9 22mm F 1 6 Lens models and availability vary in different regions Back Light Comp ON OFF Switch Auto Gain Control ON OFF Switch Flickerless ON OFF Switch Auto White Balance Yes Gamma Correction 0 45 Video Output 2 video outputs BNC 1 0Vp...

Страница 4: ...rating Temperature 40 C 50 C 40 F 122 F 20 80 Humidity Certifications FCC CE DIMENSIONS INSTALLATION 1 Loosen the 4 fix screws on the housing cover by using the attached wrench Figure 1 Carefully uncap the housing cover as the direction shown below Figure 2 please pay attention not to damage the lens To remove the housing cover push the hinges to the bottom of the bracket the hinges can be easily ...

Страница 5: ...e right toward heater direction as shown in Figure 3 remove the camera from the mounting base Reinstall the camera and the cable while the base mounting is completed 3 Mounting the base Conduit plug setscrew Side conduit entry Back conduit entry Mounting Setscrew Mounting Setscrew Mounting Setscrew Mounting Setscrew Locking Screws Vari Focal Lens Heater Figure 1 Figure 3 Figure 4 ...

Страница 6: ...he diameter of the screw hole isψ4 7mm Caution To prevent moisture leaking into the housing apply an appropriate gasket or sealant around the conduit connection The camera comes with a conduit plug pre installed in the PF 1 2 conduit entry on the side The screw can be removed and installed in the back conduit entry Loosen the conduit plug setscrew as shown in Figure 5 before removing the conduit p...

Страница 7: ... the wall please aim the Wall in line with the triangle S marked on the lead frame Factory default 2 When mounting COLOR RUGGED DOME CAMERA on the ceiling please aim the Ceiling in line with the triangle S marked on the lead frame 6 Figure 6 1 Wall Ceiling Figure 6 2 ...

Страница 8: ...adjustment screw is located on the termination board The vertical phase may require adjustment to synchronize the vertical phase of the camera with other camera in the system when it is to be used in the line lock Termination Board Video Alarm COM Micro Switch for Alarm trigger GND Alarm NO Alarm NC Power In V Phase Adjustment VR Figure 7 Power In ...

Страница 9: ...ated 360 horizontally 140 vertically and 60 3 rd axis view angles as shown in Figure 8 Adjust the proper camera view angle as needed If a vari focal lens is used you may adjust the focus and zoom of the lens to bring the object in focus Be sure to loosen the locking screws on the lens before you make adjustment Figure 8 Lens fixing Screws 140 360 60 ...

Страница 10: ...t stick is shown as below b While zooming In Out with the adjustment stick it may obstruct other adjustments of Iris Level and Video Output c In this case you can gently take off the adjustment stick and place it to the other hole at its right hand side This will allow you to adjust zooming function smoothly ...

Страница 11: ...10 ...

Страница 12: ...cal synchronization can be driven by the AC signal in the power lines Note Line Lock sync mode operation is possible only when used with an AC power source it is not possible with a DC power source The default setting is OFF AGC Automatic Gain Control OFF ON AGC ON The sensitivity increases automatically when light is low AGC OFF A low noise picture is obtained under a low light condition The defa...

Страница 13: ...L Flickerless Function ON OFF When picture flicker fiercely turn FL on then the camera will stabilize the speed of electronic shutter at 1 100 NTSC or 1 120 PAL automatically and reduce the flicker immediately The default setting is OFF IRIS Level Adjustment Brightness Level can be adjusted from the IRIS level VR Turn counterclockwise to L to get darker picture Turn clockwise to H to get brighter ...

Страница 14: ... instruction as follows 1 Adjust all settings first and place the desiccant pack on the horizontal rod then bend the horizontal rod and fix it 2 Install the outer cover and tighten the screws Installation steps for the EHD series Step 1 Step 2 Step 3 Desiccant pack Horizontal rod Bend the horizontal rod and fix the desiccant pack Install the outer cover and tighten the screws ...

Страница 15: ...or used electrical and electronic product Please help us to conserve the environment we live in Ihr EverFocus Produkt wurde entwickelt und hergestellt mit qualitativ hochwertigen Materialien und Komponenten die recycelt und wieder verwendet werden können Dieses Symbol bedeutet dass elektrische und elektronische Geräte am Ende ihrer Nutzungsdauer vom Hausmüll getrennt entsorgt werden sollen Bitte e...

Отзывы: