5
Connect the power supply cable (12VDC/24VAC), video output and alarm
output to the proper connectors shown as Figure 5.
The V. Phase adjustment screw is located on the termination board. The
vertical phase may require adjustment to synchronize the vertical phase of the
camera with other camera in the system when it is to be used in the line-lock
sync mode. Make the adjustment when the vertical phase of the camera does
not match with other cameras.
5. View Angle Adjustment
The camera can be rotated 360
°
horizontally, 140
°
vertically and 60
°
3’rd axis
view angles (as shown in Figure 6). Adjust the proper camera view angle as
needed. If a vari-focal lens is used, you may adjust the focus and zoom of
the lens to bring the object in focus. Be sure to loosen the locking screws on
the lens before you make adjustment.
Video
Alarm COM
Micro Switch for Alarm trigger
GND
Alarm NO
Alarm NC
Power In
(+)
V. Phase Adjustment VR
Figure 5
Power In
(-)