3.11.2 HDD TEMP.
The enduring HDD temperature surveillance guarantees an alarm reaction in case the
threshold value is exceeded.
There may be several reasons for HDD temperature excess:
•
Exceedance of the max. tolerable ambient temperature (40°C), e.g. upon
installation in an electrical cabinet with inadequate ventilation
•
After-effect upon fan failure
•
HDD defect
(1) BUZZER:
By selecting “ENABLE”, the buzzer is activated upon HDD
temperature excess.
(2) ALARM OUTPUT:
Output relay activation.
1:
Output relay switches upon alarm.
NONE:
no output relay reaction upon alarm.
(3) ALARM DURATION: PERMANENT
This value cannot be changed, alarm is
automatically
switched off after problem has
been
solved.
(4) NETWORK ALARM: YES:
Network alarm activated (for settings refer to
NETWORK
menu)
Network alarm reception requires optional
PowerCon software.
NO:
No network alarm transmission
(5) EMAIL:
YES:
Alarm email transmission (for settings refer
to NETWORK menu).
NO:
No email alarm transmission.
(6) STOP RECORD
YES:
Recording process is stopped to avoid further
temperature rise and HDD damage.
NO:
Recording process continues.