Содержание ETF1

Страница 1: ...Owner s Manual Undercounters Side Mounted Condensing Unit ETR1 ETR1 24 ETR2 ETR2 24 ETWR2 ETR3 ETF1 ETF1 24 ETF2 ETF2 24 ETWF2 ETF3 ETRF2 ETRF3 ETGSR2 ETGR2 ETGWR2 www everestref co m ...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...

Страница 3: ...TF1 24 ETF2 ETF2 24 ETWF2 ETF3 ETRF2 ETRF3 ETGSR2 ETGR2 ETGWR2 Contents 1 Hydrocarbon Guidelines 1 2 Installation Instructions 3 3 General Safety 6 4 Electrical Safety 7 5 Operation 8 6 Care and Maintenance 1 3 7 Troubleshooting Guide 1 6 8 Warranty Information 1 8 Everest Owner s Manual ...

Страница 4: ...onsult Service Manual or Owner s Manual before attempting to install or service this product All safety precautions must be followed CAUTION Risk of fire or explosion Flammable refrigerant used Dispose of properly in accordance with federal or local regulations CAUTION Risk of fire or explosion due to puncture of refrigerant tubing follow handling instructions carefully Flammable refrigerant used ...

Страница 5: ...s or high surface temperatures Avoid unit installation in small confined spaces Ensure ample ventilation at all times Keep all exhaust vents free of any blockage or obstruction Do not rely on smell to detect potential leaks of propane refrigerant Propane refrigerant is a high purity propane gas and does not contain odourants or stenching agents These additives are typically used in fuel grade prop...

Страница 6: ...compressor activity in order to maintain the desired cabinet temperature This will result in decreased performance advanced component failure and the risk of fire 7 A distance of 6 is required for back side and left side clearance This ensures proper ventilation and prevents overheating which can lead to advanced component failure and the risk of fire 8 Select a location with a hard leveled surfac...

Страница 7: ...dify the shape of the shelf clips This will result in shelf mounting instability Shelf Installation 2 Place shelves on the shelf clips making sure all corners are mounted securely and evenly with identical distance from the unit s floor and up Always lay the back of each shelf down on the rear clips before the front 3 When removing a shelf unmount the shelf from the shelf clips To detach the shelf...

Страница 8: ...ns 5 2 Load Level 9 Load Level 9 Shelf Airflow Guard Door Air Vent Fan Airflow Load Level 9 Load Level 9 2 Product Load Level Shelf Placement Front Rear Front Side ET Series Solid Door Models and ETG Series Glass Door Models ...

Страница 9: ... serious injury Do not climb stand or hang on the shelves doors or drawers of the unit This can damage the unit and lead to serious injury Do not touch the freezer interior if your hands are wet or damp This may lead to freezer burn or cause your skin to stick to the cold surface If you suspect a refrigerant leak or a compromised refrigeration system disconnect the unit and contact Everest Refrige...

Страница 10: ...g of circuit wires which may lead to a fire Do not use extension cords adapter plugs or other third party electrical connections Everest is not responsible for issues resulting from improper electrical connections electrical power failures and voltage fluctuations Everest does not recommend the use of generators in conjunction with the unit due to voltage fluctuations that may compromise electrica...

Страница 11: ... F 2 0 C for refrigerators and 4 0 F 20 0 C for freezers The factory recommended temperature range is between 33 0 F 1 0 C to 40 0 F 4 0 C for refrigerators and 5 0 F 21 0 C to 0 F 18 0 C for freezers Setting the temperature outside of the recommended range will cause performance issues and in some cases may result in component failure that is outside of warranty coverage The compressor condenser ...

Страница 12: ...ton for 2 seconds until the LED blinks SET alternating with a number The blinking number is the current set temperature CAUTION If PS appears on the LED This means the Temperature Set button was held down longer than 3 seconds To exit this mode and restart press Temperature Set Button Alarm in Progress Compressor Running Power Up Button Cabinet in Defrost Manual Defrost Down Button Evaporator Fan ...

Страница 13: ...perature and exit the setting mode The LED will return to the current cabinet temperature Initiating Manual Defrost The controller has an automatic defrost cycle in place so initiating manual defrost is not necessary unless there is an abnormal accumulation of ice around the evaporator coil 1 Press and hold down the Manual Defrost Button until the Defrost Symbol appears on the LED display The comp...

Страница 14: ... F to 54 0 F 1 0 C to 12 0 C for Refrigerators and 10 0 F to 54 0 F 23 0 C to 12 0 C for Freezers 4 Press and hold the Temperature Set Button for 3 seconds to save the new temperature and exit the setting mode The LED will return to the current cabinet temperature Everest units are equipped with a Carel Digital Temperature Control The type of controller is dependent on the model and production dat...

Страница 15: ...und the evaporator coil 1 Press and hold down the Manual Defrost Button until the Defrost Symbol appears on the LED display The compressor condenser and evaporator fan motors will stop running The refrigeration system will remain in defrost cycle for 45 minutes or until the evaporator coil reaches the safety termination temperature setting Initiating Manual Defrost ...

Страница 16: ...t with mild soap and warm water Do not let water accumulate inside the unit To prevent water damage wipe the interior of the unit with a dry cloth as needed Do not use steel wool strong acids concentrated detergents bleaches cleaning waxes polishers and other abrasive cleaners Do not allow moisture come in contact with electronic parts to avoid the risk of fire Clean the exterior of the product wi...

Страница 17: ...s void if the following guidelines are not met Condenser Coil Air Filter Cleaning Instructions 1 Disconnect the unit from the outlet before performing maintenance 2 Locate the condenser coil panel door at the front left side of the unit Swing open the panel door to access the condenser coil air filter The condenser coil air filter is a black rectangular leather framed mesh fabric mounted at either...

Страница 18: ...in a vertical sweeping motion to remove lint dust and debris from in between the metal fins of the condenser coil Do not apply heavy pressure so as not to bend the fins 3 Use a commercial condenser coil cleaner for metal fins that are coated in grease Allow the cleaner to saturate the area Follow the recommended wait time printed on the product packaging 4 The grease and cleaning solvent will pool...

Страница 19: ...ay be exhibiting behavior that is typical of standard operation Observe the following when troubleshooting symptoms The compressor operates continuously or for prolonged periods The condenser coil or condenser coil air filter may be clogged with dust grime or debris Clean them following the instructions in Chapter 6 The door drawer or gasket may not be sealing properly Check product placement in t...

Страница 20: ...daries of the shelf to prevent blockage of air flow Condensation in the interior cabinet The door drawer or gaskets may not be sealing properly If the gasket is loose reattach Check product placement in the cabinet as it may prevent the door from fully closing Hot food items may have been stored in the cabinet The interaction between hot and cold temperatures will promote condensation Unsealed or ...

Страница 21: ...anently affixed label that contains the model serial barcode numbers and refrigeration data of your Everest product This tag is located in the upper left or right interior compartment for models with doors or the exterior left or right exterior housing for models with drawers Please retain this information for service related purposes 8 Warranty Information Register your Everest product within thi...

Страница 22: ...mitations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty A NON WARRANTY PARTS EVEREST excludes specific parts exposed to normal wear and tear These parts include but are not limited to lamps gaskets casters shelves and shelf clips pans bin and pan dividers and airflow guards B INDIRECT OR CONSEQUENTIAL DAMAGE ...

Страница 23: ...A Step Above The Standard 201 W Artesia Blvd Compton CA 90220 Tel 800 444 6285 310 323 6586 Fax 310 323 7524 310 761 1127 www EVERESTref com ...