background image

Electrical Safety

7

Everest units in this family are equipped with a NEMA
5-15P plug. A 15 amp breaker must be used for units
that come with a NEMA 5-15P plug.

EMGF23 models in R404A come as 115 volts, 60 
hertz, single phase.

EMGF36, EMGF48, EMGF69 models in R404A come 
as 230 volts, 60 hertz, single phase.

The ground prong must not be removed to reduce 
the risk of electric shock and related hazards.  If the 
grounding pin is missing, the cord must be removed 
from use. If the outlet is a standard 2-prong outlet, it 
must be replaced with the properly grounded 3-prong 
wall outlet. Only a qualified electrician may install the 
correct power source.

To guarantee electrical safety, the wall outlet and 
circuit must be checked by a qualified electrician to 
make sure it is properly grounded. 

Remove debris from the power plug prongs with a 
soft cloth or brush before connecting it to an outlet.

Assign the unit to a dedicated, undamaged electrical 
circuit with a voltage rating that matches the data 
plate. Check the incoming voltage with a multi-meter. 
This avoids the overloading and overheating of circuit 
wires which may lead to a fire. 

Do not use extension cords, adapter plugs or 
other third party electrical connections. Everest is 
not responsible for issues resulting from improper 
electrical connections, electrical power failures and 
voltage fluctuations.

Everest does not recommend the use of generators in 
conjunction with the unit due to voltage fluctuations 
that may compromise electrical components.

Turn off the unit using the power button before 
unplugging. Wait at least 5 minutes before 
re-plugging to prevent damage to the compressor. 

Do not unplug the unit by tugging on the power cord. 
Grip the plug and pull it securely out of the outlet.

Prevent damage to the power cord by providing 
sufficient clearance around and under the unit. 
Do not use a power cord that shows cracks or 
exposed wires. Power cords that have been severely 
worn or damaged must be replaced with original 
manufacturer parts and only by an authorized 
technician.

4.   Electrical Safety

This section applies to all Everest products. Basic safety precautions must be observed when using 
electrical appliances in addition to the following. Warranty is void if these guidelines are not met.

115/60/1
NEMA 5-15R

230/60/1
NEMA 5-15R

Содержание EMGF23

Страница 1: ...Owner s Manual Merchandiser Freezers EMGF2 3 EMGF3 6 EMGF4 8 EMGF69 www EVERESTref com...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...48 EMGF6 9 Contents 1 Hydrocarbon Guidelines 1 2 Installation Instructions 3 3 General Safety 6 4 Electrical Safety 7 6 Operation 8 7 Care and Maintenance 1 3 8 Troubleshooting Guide 1 7 9 Warranty In...

Страница 4: ...nsult Service Manual or Owner s Manual before attempting to install or service this product All safety precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance...

Страница 5: ...or high surface temperatures Avoid unit installation in small confined spaces Ensure ample ventilation at all times Keep all exhaust vents free of any blockage or obstruction Do not rely on smell to...

Страница 6: ...F 30 C promote excessive compressor activity in order to maintain the desired cabinet temperature This will result in decreased performance advanced component failure and the risk of fire 7 A distance...

Страница 7: ...imping tools to modify the shape of the shelf clips This will result in shelf mounting instability 2 Place shelves on the shelf clips making sure all corners are mounted securely and evenly with ident...

Страница 8: ...Installation Instructions 5 EMGF Series Product Load Level Shelf Placement...

Страница 9: ...serious injury Do not climb stand or hang on the shelves doors or drawers of the unit This can damage the unit and lead to serious injury Do not touch the freezer interior if your hands are wet or dam...

Страница 10: ...ids the overloading and overheating of circuit wires which may lead to a fire Do not use extension cords adapter plugs or other third party electrical connections Everest is not responsible for issues...

Страница 11: ...for refrigerators and 4 0 F 20 0 C for freezers The factory recommended temperature range is between 33 0 F 1 0 C to 40 0 F 4 0 C for refrigerators and 5 0 F 21 0 C to 0 F 18 0 C for freezers Setting...

Страница 12: ...on for 2 seconds until the LED blinks SET alternating with a number The blinking number is the current set temperature CAUTION If PS appears on the LED This means the Temperature Set button was held d...

Страница 13: ...erature and exit the setting mode The LED will return to the current cabinet temperature Initiating Manual Defrost The controller has an automatic defrost cycle in place so initiating manual defrost i...

Страница 14: ...F to 54 0 F 1 0 C to 12 0 C for Refrigerators and 10 0 F to 54 0 F 23 0 C to 12 0 C for Freezers 4 Press and hold the Temperature Set Button for 3 seconds to save the new temperature and exit the sett...

Страница 15: ...nd the evaporator coil 1 Press and hold down the Manual Defrost Button until the Defrost Symbol appears on the LED display The compressor condenser and evaporator fan motors will stop running The refr...

Страница 16: ...rature leading to possible food spoilage or component failure Clean the interior surface of the unit with mild soap and warm water Do not let water accumulate inside the unit To prevent water damage w...

Страница 17: ...oduct s energy efficiency and places strain on the compressor and other components leading to advanced failure Cleaning the condenser coil is the product owner s personal responsibility Warranty is vo...

Страница 18: ...e top of the vented grill 2 Pull on the top edge of the vented grill Swing Doors 3 Lift the vented grill vertically until the two keyholes on its bottom edge clears the stationary bolts 4 The condense...

Страница 19: ...area Follow the recommended wait time printed on the product packaging 5 The grease and cleaning solvent will pool at the base of the metal fins Brush the fins and wipe off any accumulated residue 6 R...

Страница 20: ...exhibiting behavior that is typical of standard operation Observe the following when troubleshooting symptoms The door or door gaskets may not be sealing properly Check product placement in the cabine...

Страница 21: ...the cabinet Keep these items in air tight containers Mild condensation in warmer ambient temperature conditions may occur due to frequent or prolonged door operation Condensation on the unit s exteri...

Страница 22: ...nently affixed label that contains the model serial barcode numbers and refrigeration data of your Everest product This tag is located in the upper left or right interior compartment for models with d...

Страница 23: ...itations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty A NON WARRANTY PARTS EVEREST excludes specific parts ex...

Страница 24: ...A Step Above The Standard 201 W Artesia Blvd Compton CA 90220 Tel 800 444 6285 310 323 6586 Fax 310 323 7524 310 761 1127 www EVERESTref com v0892019...

Отзывы: