background image

Chef Bases

ECB36D2, ECB48D2, ECB52D2, ECB52-60D2, ECB7 2D4, ECB82D4, ECB82-84D4 
ECB82-86D4, ECB9 6D4

Contents

1.   Hydrocarbon Guidelines   

  

1

2.   Installation Instructions   

  

3

3.

   

General Safety   

  

6

4.   Electrical Safety   

  

7

5.   Operation   

  

8

6.   Care and Maintenance   

  

1 3

7.   Troubleshooting Guide   

  

1 5

8.   Warranty Information    

 

1 8

Everest Owner’s Manual

Содержание ECB36D2

Страница 1: ...Owner s Manual Chefbases ECB3 6D2 ECB48D2 ECB52D2 ECB52 60D2 ECB7 2D4 ECB82D4 ECB82 84D4 ECB82 86D4 ECB9 6D4 www e ve re stref co m...

Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 3: ...ECB82 84D4 ECB82 86D4 ECB9 6D4 Contents 1 Hydrocarbon Guidelines 1 2 Installation Instructions 3 3 General Safety 6 4 Electrical Safety 7 5 Operation 8 6 Care and Maintenance 1 3 7 Troubleshooting Gu...

Страница 4: ...sult Service Manual or Owner s Manual before attempting to install or service this product All safety precautions must be followed CAUTION Risk of fire or explosion Dispose of properly in accordance w...

Страница 5: ...or high surface temperatures Avoid unit installation in small confined spaces Ensure ample ventilation at all times Keep all exhaust vents free of any blockage or obstruction Do not rely on smell to...

Страница 6: ...lace your hands under the top surface lip or on the unit chassis when moving it to avoid injury from sharp edges protruding parts or weight impact 7 Select a location with good air ventilation Poor ve...

Страница 7: ...he risk of fire 15 The unit is not intended for use in food trucks Limited space lack of ventilation and ambient temperatures exceeding 86 F 30 C typical to this setting will result in elevated compre...

Страница 8: ...B48D2 Standard 2 1 size pans 3 1 6 size pans 4 deep w 2 pan dividers per drawer included ECB52D2 ECB52 60D2 ECB82D4 ECB82 84D4 ECB82 86D4 ECB96D4 Standard 3 1 size pans 4 deep w 2 pan dividers per dra...

Страница 9: ...rious injury Do not climb stand or hang on the shelves doors or drawers of the unit This can the damage the unit and lead to serious injury Do not touch the freezer interior if your hands are wet or d...

Страница 10: ...of circuit wires which may lead to a fire Do not use extension cords adapter plugs or other third party electrical connections Everest is not responsible for issues resulting from improper electrical...

Страница 11: ...commended temperature range is between 33 0 F 1 0 C to 40 0 F 4 0 C for refrigerators and 5 0 F 21 0 C to 0 F 18 0 C for freezers Setting the temperature outside of the recommended range will cause pe...

Страница 12: ...on for 2 seconds until the LED blinks SET alternating with a number The blinking number is the current set temperature CAUTION If PS appears on the LED This means the Temperature Set button was held d...

Страница 13: ...perature and exit the setting mode The LED will return to the current cabinet temperature Initiating Manual Defrost The controller has an automatic defrost cycle in place so initiating manual defrost...

Страница 14: ...F to 54 0 F 1 0 C to 12 0 C for Refrigerators and 10 0 F to 54 0 F 23 0 C to 12 0 C for Freezers 4 Press and hold the Temperature Set Button for 3 seconds to save the new temperature and exit the sett...

Страница 15: ...nd the evaporator coil 1 Press and hold down the Manual Defrost Button until the Defrost Symbol appears on the LED display The compressor condenser and evaporator fan motors will stop running The refr...

Страница 16: ...water Do not let water accumulate inside the unit To prevent water damage wipe the interior of the unit with a dry cloth as needed Do not use steel wool strong acids concentrated detergents bleaches c...

Страница 17: ...o as not to bend the fins 3 Use a commercial condenser coil cleaner for metal fins that are coated in grease Allow the cleaner to saturate the area Follow the recommended wait time printed on the prod...

Страница 18: ...of standard operation Observe the following when troubleshooting symptoms The power cord may not be connected Check for proper connection In cases of damage to the power cord or plug immediately mark...

Страница 19: ...ent temperature may be higher than 86 F 30 C Provide ample ventilation or additional cooling to the room Relocate the unit from extremely small spaces without ventilation The front and left side vents...

Страница 20: ...e front of the unit Noise level during unit operation It is normal for commercial grade compressors and components to have a higher decibel output compared to residential counterparts The unit may not...

Страница 21: ...affixed label that contains the model serial barcode numbers and refrigeration data of your Everest product This tag is located in the upper left or right interior compartment for models with doors o...

Страница 22: ...tations below This warranty neither assumes nor authorizes any person to assume obligations other than those expressly covered by this warranty A NON WARRANTY PARTS EVEREST excludes specific parts exp...

Страница 23: ...A Step Above The Standard 201 W Artesia Blvd Compton CA 90220 Tel 8 00 444 6 28 5 310 323 6 58 6 Fax 310 323 7524 310 76 1 1127 www EVERESTref com...