
DESIGNED TO PERFECTION
APPLIANCE DETAILS
ELECTRICAL DETAILS:
OVENS:
Rated Voltage:
220 to 240 Vac 50 Hz
Max Rated Inputs:
OBES601- 2600W & OBES602 - 3100W
Supply Connection: OVENS - 15 A plug
This information can be found on the rating plate (data label) affixed to the inside of the door jamb.
SIZES:
ELECTRICAL CONNECTIONS
LOCAL AUTHORITY REQUIREMENTS
Installation is only permitted by a licensed electrician, and carried out according to instructions
provided by the manufacturer. Incorrect installation might cause harm and damage which the
manufacturer accepts no responsibility.
ELECTRICAL INSTALLATION FOR THE LICENSED ELECTRICIAN
This oven must be connected to a 220-240V 50Hz power supply. It is earthed via the cord and 15A plug.
Before carrying out the connection to the power supply, the voltage rating of the appliance (stamped on the
appliance identification plate) must be checked for correspondence to the available mains supply voltage, and
the mains electric wiring should be suitable for the oven’s power rating (also indicated on the appliance
identification plate);
The switched outlet must be connected to a suitable earth wiring, in conformity to current safety regulations.
This appliance must be plugged into a 15A switched outlet. It should not be located above the appliance and
no more than 1.25m away from it. The power supply cord must not touch against any hot surfaces and must
be placed so that its temperature does not exceed 75°C at any point along its length.
After having installed the appliance, the switched outlet must always be in an accessible position.
NOTE: For connections to the mains power supply, never use adapters, reductions or multiple power points as
these may overheat and catch fire.
The mains terminal block is located on the back of the oven and the terminals are accessible by opening the
terminal block cover. Note: The terminal cover should not be opened when the mains power is still connected
to the appliance and never by an unauthorized person.
The electrical safety of this appliance can only be guaranteed if the oven is correctly and efficiently earthed. The
manufacturer declines all responsibility for damage resulting from an installation which has not been earthed
correctly.
The use of adapters, multiple sockets and/or extensions, is not allowed.
Relevant Sizes:
LENGTH (mm)
DEPTH (mm)
HEIGHT (mm)
External
Oven
size
595 575 595
4
Содержание OBES601
Страница 23: ...DESIGNED TO PERFECTION 23...