BEFORE YOU INSTALL THIS PUMP 

 

 

WARNING: 

Risk of explosion. Do not ground to a gas supply line. The pump body may explode if used as a booster pump or other than a 

lawn sprinkling application.

 

 

 

CAUTION: 

Risk of burns. Do not touch an operating motor. Motors are designed to operate at high temperatures. It is protected from heat 

damage during operation by an automatic internal cutoff switch. To avoid burns when servicing the pump, allow it to cool for 20 minutes after 
shut down before handling.

 

 

 

The pump’s water suction inlet must not be more than 20 ft. above the water level. 

 

Long runs and many fittings increase friction and reduce water flow to the pump. Locate the pump as close to the water source as 
possible. Use as few elbows and fittings as possible. Ensure the suction line is straight and angles up toward the pump. 

 

Ensure the well and pipe are clear of sand, dirt, and scale. Foreign matter will plug the pump and void the warranty. Use new pipe 
for best results. 

 

Protect the pump and all piping from freezing. 

 

Freezing will split pipe, damage the pump and void the warranty. Check locally for frost protection requirements. The pump cannot 
be installed below the frost line and the pump must be insulated. 

 

Foot or check valves (not included) must be installed in the suction pipe to optimize pump suction. 

 

Ensure all pipes and valves are clean and in good shape. 

 

Ensure there are no air pockets in the suction pipe. 

 

Ensure there are no leaks in the suction pipe. Use Teflon tape or other approved sealants to seal pipe joints. 

 

Unions installed near the pump and well will aid in servicing. Leave room to use wrenches. 

LAWN SPRINKLING APPLICATION 

This pump is designed for lawn sprinkling. When  properly installed it will deliver adequate water and  pressure from any well source. 

PERFORMANCE DATA 

SKU

HP 

DISTANCE OF PUMP 
ABOVE WATER 

DISCHARGE PRESSURE 

PSI

 

10

20

30

40

GALLONS PER MINUTE

092

5 ft. 

60

56

51

37

10 ft. 

53

50

46

32

15 ft. 

47

44

41

25

20 ft. 

41

38

34

22

 

 

1-1/2 

245

1001

MATERIALS REQUIRED (NOT INCLUDED) 

Before using this pump, ensure you have the following items: 

 

 

1-1/2 in. 
Suction/Discharge
pipe 

 

Thread sealant 
tape 

 

1-1/2 in. Check valve 

 

1-1/2 in. Elbow 

 

1-1/2 in. 
Union 

 

1-1/2 in. Gate valve 

 

 

  

 4 

1-1/2 in. Adaptor

Содержание EFLS15CI-HD

Страница 1: ...your home Visit us online to see our full line of products available for your home improvement needs Thank you for choosing Everbilt Item 1001 092 245 Model EFLS15CI HD USE AND CARE GUIDE 1 1 2 HP CAS...

Страница 2: ...safety symbols and their meanings DANGER Indicates a hazard which if not avoided will result in death or serious injury WARNING Indicates a hazard which if not avoided could result in death or seriou...

Страница 3: ...arranty information label are required to determine warranty eligibility Eligibility is based on purchase date of original product not the date of replacement under warranty The warranty is limited to...

Страница 4: ...ng from freezing Freezing will split pipe damage the pump and void the warranty Check locally for frost protection requirements The pump cannot be installed below the frost line and the pump must be i...

Страница 5: ...e sure all suction pipe is leak proof or the pump will lose prime and fail to pump Install foot valve 10 to 20 ft 3 to 6 m below the lowest level to which water will drop while the pump is operating p...

Страница 6: ...nstallation and operation instructions call Customer Service Use rigid pipe Do not use hose or plastic tubing See Well Pipe Installation for more information Use only PTFE pipe thread sealant tape to...

Страница 7: ...upply Failure to ground the motor can cause severe or fatal electrical shock hazard 3 Supply voltage must be within 10 of the nameplate voltage Incorrect voltage can cause fire or damage the motor and...

Страница 8: ...e system and beginning to move water from its source out into the system It does not refer only to pouring water into the pump although pouring water in is usually the first step CAUTION Risk of burns...

Страница 9: ...logged with debris 1 Unplug the pump from electrical power 2 Remove four screws 8 3 Remove the volute 2 O ring 2 and O ring 3 4 Remove three screws 4 fastening the diffuser 5 to the seal plate 7 and r...

Страница 10: ...k valve is leaking Replace the foot valve or check valve The pipe size is too small Re pipe using the size of suction and discharge ports on the pump The water level is below the suction pipe inlet Lo...

Страница 11: ...11 HOMEDEPOT COM Please contact 1 844 883 1872 for further assistance Service Parts NO Quantity Part Number Description 1 1 HDLS15007 O Ring NBR 2 1 HDLS15008 O Ring NBR 2 1...

Страница 12: ...Questions problems missing parts Before returning to the store call Everbilt Customer Service 8 a m 6 p m EST Monday Friday 1 844 883 1872 HOMEDEPOT COM Retain this manual for future use...

Страница 13: ...Everbilt de lunes a viernes de 8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM GRACIAS Apreciamos la confianza que ha depositado en Everbilt por la compra de esta bomba Nos esforzamos p...

Страница 14: ...grosa que si no se evita resultar en la muerte o lesiones graves ADVERTENCIA Indica una situaci n peligrosa que si no se evita podr a resultar en la muerte o lesiones graves PRECAUCI N Indica una situ...

Страница 15: ...la fecha de compra del producto original y no en la fecha del reemplazo bajo la garant a La garant a est limitada a la reparaci n o reemplazo del producto original comprado nicamente no al producto d...

Страница 16: ...romper la tuber a da ar la bomba y anular la garant a Consulte localmente en busca de requisitos de protecci n contra la escarcha La bomba no se puede instalar abajo de la profundidad de penetraci n d...

Страница 17: ...para la tuber a de succi n Aseg rese de que toda la tuber a de succi n sea a prueba de fugas o la bomba perder cebado y dejar de bombear Instale la v lvula de pie de 10 a 20 pies 3 a 6 m abajo de niv...

Страница 18: ...nterruptor de presi n y tanque Para una instalaci n e instrucciones de operaci n adecuadas llame a Servicio al cliente Use tuber a r gida No use manguera ni tuber a pl stica Consulte Instalaci n de tu...

Страница 19: ...ricos severos o fatales 3 El voltaje de alimentaci n debe estar dentro de 10 del voltaje de la placa de identificaci n El voltaje incorrecto puede ocasionar un incendio o da ar el motor y anular la ga...

Страница 20: ...n el sistema y comenzar a mover agua de su fuente al sistema No se refiere nicamente a vertir agua a la bomba aunque vertir agua generalmente es el primer paso PRECAUCI N Riesgo de quemaduras NUNCA po...

Страница 21: ...tornillos 8 3 Retire la voluta 2 el anillo O 2 el anillo O 3 4 Retire los tres tornillos 4 que sujetan el difusor 5 a la placa de sello 7 y retire el difusor 5 5 Retire los desechos alrededor del imp...

Страница 22: ...pie o la v lvula de retenci n El tama o de la tuber a es demasiado peque o Reinstale la tuber a usando el tama o de puertos de succi n y descarga en la bomba El nivel del agua est debajo de la entrada...

Страница 23: ...iezas de servicio NO Cantidad N mero de pieza Descripci n 1 1 2 1 HDLS15007 Anillo O NBR HDLS15008 Anillo O NBR 11 HOMEDEPOT COM P ngase en contacto con el 1 844 883 1872 para asistencia adicional 2 1...

Страница 24: ...8 a m a 6 p m hora local del Este 1 844 883 1872 HOMEDEPOT COM Conserve este manual para uso futuro Tiene preguntas problemas o faltan piezas Antes de regresar a la tienda llame a Servicio al Cliente...

Отзывы: