5 HOMEDEPOT.COM
Please contact 1-844-241-5521 for further assistance.
Installation
4" Cased (Drilled) Well
1. Determine the length of flexible plastic pipe needed to locate the ejector at the proper depth (your well driller
should supply this information). Measure carefully and cut suction (1-1/4") and drive (1") pipes to length.
NOTE
: As a guide, set the ejector 10 to 20 feet below the lowest water level reached with the pump running, but always at least five
feet above the bottom of the well (See Figure 7).
Figure 7
2. Connect the plastic pipes to the adapters with hose clamps (See Figure 8); use two clamps per joint. Put the
tightening screws on opposite sides of the pipe as shown.
NOTE
: Clamp the pipe securely and only use clamps that are all stainless steel.
3. Install steel nipples in the sanitary well seal.
NOTE
: To allow correct alignment of the pipes with the pump ports, the 1-1/4" (suction) pipe must run above the 1" (drive) pipe. Adjust
the height of the nipples in the well seal to allow for this.
Figure 8