10….Power Switch
System main power, switch on and the power light will light up.
11….Timer Switch
Timer controller, switch on and the power light will light up.
4. Operation
:
a.
Please refer to table 1 for appropriate needle and pressure setting.
b.
If the adhesive is dripping from barrel, turn up the vacuum until it is not dripping.
c.
Turn off the timer switch; use the foot pedal to activate the dispensing until the adhesive fill up the needle and
flow out the barrel smoothly. If the adhesive cannot flow out the barrel please adjust the pressure or replace the
needle and repeat step a again.
d.
Place the barrel 45 degree to the process object and fit the needle on top of the dispensing point.
e.
– Manual dispensing
:
turn off the timer switch and step on the foot pedal to activate the dispensing, remove to
stop the dispensing. Timer display will display the current dispensing time for your reference. It is suitable for long
straight line and irregular dispensing route.
– Timer dispensing
:
turn on the timer switch and set the timer; step on the foot pedal once to activate one single
timed dispensing, repeat the process by stepping the pedal again. It is suitable for repeat and uniform dispensing
route.
5. Three main reasons that control the dispensing volume
:
Needle type and size
Air pressure volume
Dispensing time
6. Maintenance and Precaution
:
The dispenser is designed and built to be relatively maintenance free. To assure trouble free operation, the following
recommendations should be followed
:
a.
Make certain air supply is clean and dry.
b.
Avoid turning barrels upside down or laying barrel so that material may run through air line to internal
components.
c.
Avoid turning the vacuum to large and cause the generation of bubbles in the material or the material to run back
into the system.
d.
If the piston inside the barrel is running up and down during the dispensing, it is mean the material has really high
viscosity and you will need to replace the piston with red or rigid piston.