Values 

Description 

d001-d512 

001-A512 

Set the DMX address. 

IP.01-IP.64 

001-512 

IP mode 

A1.01 

A1.01-A1.19 

Static colour mode. Press 
enter to save. 

A2.01 

A2.01-A2.19 

Jump colour change mode. 
Press enter to save. 

A3.01 

A3.01-A3.19 

Multicolour mode. Press enter 
to save. 

A4.01 

A4.01-A4.19 

Sound active mode. Press 
enter to save. 

A5.01 

A5.01-A5.19 

Strobe mode. Press enter to 
save. 

r.000 

r.000-r.255 

Red intensity 

G.000 

G.000-G.255 

Green intensity 

b.000 

b.000-b.255 

Blue Intensity 

 

DMX Chart 

This fixture is controlled by the universal DMX 512 protocol. The DMX address is the first 
channel used to receive instructions from the external controller. For independent control, 
each fixture must be assigned a unique address for each of its control channels. For 
example, this device has one channel modes: 8, if it’s set to 8 channel mode, and there are 
several fixtures need to be independently controlled, we just simply address first fixture at 1, 
and second fixture at 9, third one at 17, etc. 

 

 

If multiple fixtures have the same DMX address, they will behave synchronically. 

 

 

Display will flash when no DMX signal is received. 

 

Channel  Min 

DMX 

Max 
DMX 

Function 

10 

No Function 

 

11 

50 

Macro A1 

 

51 

100 

Macro A2 

 

101 

150 

Macro A3 

 

151 

200 

Macro A4 

 

201 

255 

Macro A5 

 

250 

255 

Red+Green+Blue 

255 

Macro Colour 

255 

Macro Speed 

255 

Master Dimmer, 0-100% 

255 

Red dimmer, 0-100% 

255 

Green dimmer, 0-100% 

255 

Blue dimmer, 0-100% 

255 

White dimmer, 0-100% 

 

 

Содержание PARTY VIVIDBAR2

Страница 1: ... Lighting reserves the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item Version 1 ...

Страница 2: ...y may affect it Do not operate this fixture if the housing lenses or cables appear damaged Do not connect this fixture to a dimmer or rheostat ONLY connect this fixture to a grounded and protected circuit ONLY use the hanging bracket to carry this fixture In case of a serious operating problem stop using immediately The maximum ambient temperature is 40 C Do not operate this fixture at higher temp...

Страница 3: ...ctions from the external controller For independent control each fixture must be assigned a unique address for each of its control channels For example this device has one channel modes 8 if it s set to 8 channel mode and there are several fixtures need to be independently controlled we just simply address first fixture at 1 and second fixture at 9 third one at 17 etc If multiple fixtures have the...

Страница 4: ...justment DMX buttons DMX channel selection IP buttons running effect Technical Specifications Light Source 24x 4W RGBW LEDs Beam angle 25 Dimming 0 100 Operation Modes DMX auto manual sound active IR remote Control Interface 3 pin XLR in out IR remote DMX Channels 8 Input Voltage 110 240V AC 50 60 Hz Power Consumption 100W Warranty Please contact your local dealer or contact Event Lighting www eve...

Отзывы: