background image

www.event-lighting.com.au 

 

 

Safety Instructions 

WARNING 

• Do not open this device, there is no user-serviceable parts inside. Risk of electric shock. 

• Do not look at the light source when the device is on. 

• 

CAUTION

: This unit's housing may be hot during and after operation. 

• Install this device in a location with adequate ventilation, at least 20 inch (50 cm) from adjacent surfaces. 

• Do not leave any flammable material within 50 cm of this unit while operating or connected to power. 

• Use a safety chain when mounting this device overhead. 

• Do not operate this device outdoors or in any location where dust, excessive heat, water, or humidity may affect it. 

• Do not operate this device if the housing, lenses, or cables appear damaged. 

• Do not connect this device to a dimmer or rheostat. 

• ONLY connect this device to a grounded and protected circuit. 

• ONLY use the hanging bracket to carry this device. 

• In case of a serious operating problem, stop using immediately. 

• The maximum ambient temperature is 104° F (40° C). Do not operate this device at higher temperatures. 

 

Power Input & Power Linking 

This device has an auto-switching power supply work with input voltage range of 100~240 VAC, 50/60 Hz. 

Link up to the maximum 8A. DO NOT exceed this number. 

 

Product Installation 

This device can be mounted in many orientations provided each individual device is secured by the use of correct 

mounting bracket. 

 

Use a safety chain when mounting this device overhead. 

 
Fuse Replacement 

If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating. 

Before replacing the fuse, unplug mains lead. 

Procedure: 

Step 1: Unscrew the fuse holder on the rear panel with a fitting screwdriver from the housing (anticlockwise). 

Step 2: Remove the old fuse from the fuse holder. 

Step 3: Install the new fuse in the fuse holder. 

Step 4: Replace the fuse holder in the housing and fix it. 

 

 

 

Содержание PAR12x8A

Страница 1: ...ghting reserves the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item www event lighting com au Ver 2 3 ...

Страница 2: ...www event lighting com au 1 CONTENTS Safety Instructions Product Installation Diagrams Control Board Operation DMX chart Technical specifications Warranty ...

Страница 3: ...it ONLY use the hanging bracket to carry this device In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this device at higher temperatures Power Input Power Linking This device has an auto switching power supply work with input voltage range of 100 240 VAC 50 60 Hz Link up to the maximum 8A DO NOT exceed this number Product In...

Страница 4: ...www event lighting com au 3 Lux Chart PARRGBW5X8 PAR5X8A PARRGBW12X8 PAR12X8A ...

Страница 5: ...www event lighting com au 4 Dimensions PAR5 PAR12 ...

Страница 6: ...00 Dim255 Select built in automatic programs auto run speed and dimmer level Mas Sla M S Select Master Slave modes Reset N Y Recover manufactory default DMX Address After select the DMX Add and press Enter use Up and Down button to select the desired DMX address press Enter to save new setting DMX Mode After select the DMX Cha and press Enter use Up and Down button to select the desired DMX mode p...

Страница 7: ... strobe off Press Enter to save new setting Auto Run Mode Function Pr 01 RGBW Model R G B W colour switching RGBA Model R G B A colour switching Pr 02 15 colour switching Pr 03 RGBW Model R G B W colour fading RGBA Model R G B A colour fading Pr 04 15 colour fading Pr 05 Color Macros Fading Pr 06 Sound active mode Pr 07 Multi fixture chases Set auto run Pr 01 Pr 05 Entered Auto Pro mode use Up and...

Страница 8: ...g including the master then set the DMX address to 2 If this the last unit of 20 then the DMX address should be set to 20 It is possible to double up fixture positions as well as fixture 1 5 On each slave go to the master slave menu setting and set it to slave Master Slave Operation Set the master fixture to one of the stand alone operating modes automatic sound static color or manual color modes ...

Страница 9: ... 6 000 009 Strobe OFF 010 255 Strobe slow fast 1 30Hz 7 000 019 No Function 020 039 RED 100 GREEN 0 100 BLUE 0 040 059 RED 100 0 GREEN 100 BLUE 0 060 079 RED 0 GREEN 100 BLUE 0 100 080 099 RED 0 GREEN 100 0 BLUE 100 100 119 RED 0 100 GREEN 0 BLUE 100 120 139 RED 100 GREEN 0 BLUE 100 0 140 159 RED 100 GREEN 0 100 BLUE 0 100 160 179 RED 100 0 GREEN 100 0 BLUE 100 180 200 RGBW Model RED 100 GREEN 100...

Страница 10: ... 155 16 bits Non linear dimmer 3 156 204 16 bits Non linear dimmer 4 205 255 8 bits Linear dimmer 5 TECHNICAL SPECIFICATIONS Model PARRGBW5X8 PAR5X8A PARRGBW12X8 PAR12X8A Dimensions and Weight Overall size LxWxH mm 207x227x120 263x293x98 Weight kg 1 9 3 2 Power Power Supply 100 240V AC 50 60 Hz Power Consumption w 40 98 Power I O IEC input connector IEC input output connector Fuse T 1 A 250 V T 2 ...

Отзывы: