Event Lighting PAN2x1x30 Скачать руководство пользователя страница 1

 

 

 

 

LED Pix Panel 

PAN8X1X30, PAN4x1x30 ,PAN4x1x15, PAN2x1x30   

USER MANUAL

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

For safety, please read this user manual carefully before initial use.

 

Event Lighting reserves the right to revise the manual at any time. Information and specifications within this manual are subject to 

change without notice. Event Lighting assumes no liability or responsibility for any errors or omissions. Please consult Event Lighting 

for any clarification or information regarding this item. 

www.event-lighting.com.au 

 

Ver 2.0 

Содержание PAN2x1x30

Страница 1: ...ting reserves the right to revise the manual at any time Information and specifications within this manual are subject to change without notice Event Lighting assumes no liability or responsibility for any errors or omissions Please consult Event Lighting for any clarification or information regarding this item www event lighting com au Ver 2 0 ...

Страница 2: ...ut Power Linking Product Installation Fuse replacement Product appearance Lux Chart Dimensions Control Board Operation DMX Addressing DMX Modes Dimmer Speed Setting Sound Mode Setting Static Colors User Mode Automatic Mode DMX Values Technical Specifications Warranty ...

Страница 3: ...ircuit ONLY use the hanging bracket to carry this device In case of a serious operating problem stop using immediately The maximum ambient temperature is 104 F 40 C Do not operate this device at higher temperatures Power Input Power Linking This device has an auto switching power supply work with input voltage range of 100 240 VAC 50 60 Hz Link up to the maximum 8A DO NOT exceed this Fuse Replacem...

Страница 4: ...www event lighting com au 3 PRODUCT APPEARANCE LUX CHART DIMENSIONS ...

Страница 5: ...tely for color mixing and strobe rate 7 Auto Program To set built in automatic programs and speed 000 100 8 Master Slave To set Master Slave modes 9 Factory Set To recover to manufactory default Use Up and Down button to select your desired operation press Enter to set all function Set DMX address After select the DMX Address and press Enter then use Up and Down to set the desired DMX address pres...

Страница 6: ...ic program through control panel Entered Auto Program mode use Up and Down to select the built in auto run programs press Enter to confirm Use Up and Down to select the operating speed of the auto program Sp 000 Sp100 freeze slow fast PAN2X1X30 PAN4X1X15 PAN4X1X30 PAN8X1X30 Pr 01 R G B colors switching R G B colors switching Pr 02 7 colors switching 7 colors switching Pr 03 R G B colors fading R G...

Страница 7: ...s to 2 If this the last unit of 20 then the DMX address should be set to 20 It is possible to double up fixture positions as well as fixture 1 5 On each slave go to the master slave menu setting and set it to slave Master Slave Operation 1 Set the master fixture to one of the standalone operating modes auto sound static color or manual color modes 2 Set the slaves entered Mas Sla mode set to s pre...

Страница 8: ... LED 3 Red 0 100 8 8 000 255 LED 3 Green 0 100 9 9 000 255 LED 3 Blue 0 100 10 10 000 255 LED 4 Red 0 100 11 11 000 255 LED 4 Green 0 100 12 12 000 255 LED 4 Blue 0 100 13 000 255 LED 5 Red 0 100 14 000 255 LED 5 Green 0 100 15 000 255 LED 5 Blue 0 100 16 000 255 LED 6 Red 0 100 17 000 255 LED 6 Green 0 100 18 000 255 LED 6 Blue 0 100 19 000 255 LED 7 Red 0 100 20 000 255 LED 7 Green 0 100 21 000 ...

Страница 9: ...UE 0 100 160 179 RED 100 0 GREEN 100 0 BLUE 100 180 200 RED 100 GREEN 100 BLUE 100 201 204 Color Temperature 1 Warm Cool 205 209 Color Temperature 2 210 214 Color Temperature 3 215 219 Color Temperature 4 220 224 Color Temperature 5 225 229 Color Temperature 6 230 234 Color Temperature 7 235 239 Color Temperature 8 240 244 Color Temperature 9 245 249 Color Temperature 10 250 255 Color Temperature ...

Страница 10: ...204 218 Effect program 9 219 233 Effect program 10 234 248 Effect program 11 249 255 Sound active mode 8 8 000 255 Speed of auto programs slow fast or sound sensitivity 9 9 000 009 Use dimmer curve from setting of control board 010 044 16 bits Linear dimmer 1 045 079 16 bits Non linear dimmer 2 080 114 16 bits Non linear dimmer 3 115 149 16 bits Non linear dimmer 4 150 184 8 bits Linear dimmer 5 1...

Страница 11: ... LED 5 Green 0 100 15 000 255 LED 5 Blue 0 100 16 000 255 LED 6 Red 0 100 17 000 255 LED 6 Green 0 100 18 000 255 LED 6 Blue 0 100 19 000 255 LED 7 Red 0 100 20 000 255 LED 7 Green 0 100 21 000 255 LED 7 Blue 0 100 22 000 255 LED 8 Red 0 100 23 000 255 LED 8 Green 0 100 24 000 255 LED 8 Blue 0 100 7 13 25 000 255 Master dimmer 0 100 8 14 26 000 009 Strobe OFF 010 255 Strobe slow fast 1 30Hz 9 000 ...

Страница 12: ...4 218 Effect program 9 219 233 Effect program 10 234 248 Effect program 11 249 255 Sound active mode 10 16 28 000 255 Speed of auto programs slow fast or sound sensitivity 11 17 29 000 009 Use dimmer curve from setting of control board 010 044 16 bits Linear dimmer 1 045 079 16 bits Non linear dimmer 2 080 114 16 bits Non linear dimmer 3 115 149 16 bits Non linear dimmer 4 150 184 8 bits Linear di...

Страница 13: ...e T 1 A 250 V T 2 A 250 V T 1 A 250 V T 8 A 250 V LED 2pcs 30W RGB COB LED 4pcs 30W RGB COB LED 4pcs 15W RGB COB LED 8pcs 30W RGB COB LED Operation Modes DMX auto run sound active master slave manual colour control static colour control Beam Angle 60 Refresh Rate 11 700Hz DMX Channel mode 3 5 9 6 11 3 5 9 12 17 3 5 9 24 29 Power Input IEC Power Output NO IEC WARRANTY Please refer to your local dea...

Отзывы: