Evenheat RampMaster II Скачать руководство пользователя страница 19

 

RampMaster II Operating Manual 

 RMII – Aug. 2015 

 

 

                         Page 

19

 of 

26

 

                                           

                                          Use your Smart-phone to scan this QR code to watch RampMaster II how-to Programming Videos!

 

 

RampMaster II Display Messages 

 

Listed below are all display messages you will encounter while using the RampMaster II. Most are self explanatory. To learn more about the messages go 

to the page number indicated.  

 

 

  

ALRM 

Alarm, page 10 

 

-ON- 

On, pages 7 & 9 

 

bd T 

Board Temperature, page 17 

 

PCT 

Percent, page 16 

 

°C x 

Temperature, page 8 

 

PCT4 

Percent, page 16 

 

°COS 

Degrees Offset, pages 15 & 16 

 

PF 

Power Failure, page 24 

 

CANL 

Cancel, page 10 

 

PRHT 

Preheat, page 13 

 

CHG° 

Change°, page 15 

 

RA x 

Rate, page 8 

 

CNOS 

Cone Offset, page 15 

 

RSET 

Reset, page 13 

 

CONE 

Cone, page 7 

 

SEGS 

Segments, page 8 

 

CPL 

Complete, page 9 

 

SKIP 

Skip to Next Segment, page 10 

 

CPLT 

Firing Complete, page 7 & 9 

 

STOP 

Stop, pages 7 & 9 

 

dELA 

Delay Start, page 12 

 

SUSP 

Suspend, page 10 

 

ERCd 

Error Codes, page 16 

 

tC 1 

Zone 1 Temperature, page 13 

 

Err

x

 

Error Code, page 23 

 

tC 2 

Zone 2 Temperature, page 13 

 

ErrP 

Brief Power Failure, page 17 

 

tC 3 

Zone 3 Temperature, page 13 

 

°F x 

Temperature, page 8 

 

TCOS 

Thermocouple Offset, page 16 

 

°FOS 

Degrees Offset, page 15 & 16 

 

USER 

User, page 8 

 

FAIL 

Fail, page 24 

 

WAIT 

Wait, page 11 

 

HLd 

Hold, page 8 

 

4HR 

4 Hour, page 7 

 

Id 

Identification, page 14 

 

7HR 

7 Hour, page 7 

 

IdLE 

Idle, pages 12 

 

10HR 

10 Hour, page 7 

 

OFF 

Off,  pages 14 

 

13HR 

13 Hour, page 7 

 

ON 

On, pages 14 

 

16-S 

16 Segments, page 14 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание RampMaster II

Страница 1: ...RampMaster II Operating Manual RMII Aug 2015 Page 1 of 26 Use your Smart phone to scan this QR code to watch RampMaster II how to Programming Videos RampMaster II Control Operating Manual...

Страница 2: ...ontrol panel to the OFF position O when not in use Table of Contents Quick Cone Fire Mode Programming 3 Quick Ramp Mode Programming 4 RampMaster II Key Layout 5 RampMaster II Key Descriptions 6 Detail...

Страница 3: ...finish the initiation process and then display IdLE along with chamber temperature 4 Press one of the Cone Fire Mode keys based on your desired total firing time Times are approximate 5 Press the Ente...

Страница 4: ...one time USER is displayed along with some number 5 Use the Numerical keys to choose You re choosing which of the 6 user programs to use Your choices are 1 thru 6 6 Press the Enter key SEGS is displa...

Страница 5: ...ture ALARM Allows you direct access to the alarm feature OTHER Menu area of the RampMaster II for various set up and configuration options CONE TABLE Allows you to look up equivalent temperatures used...

Страница 6: ...reen firing Firing time is approximate 10 Hr FAST BISQUE Pre set Cone Fire Mode choice Provides a multi segment program specifically designed for a general green firing Firing time is approximate 7 Hr...

Страница 7: ...our Cone Fire Mode keys one time The approximate firing time will be displayed 2 Press the Enter key CONE is displayed along with the previously selected cone number 3 Use the Numerical keys to choose...

Страница 8: ...the 6 available locations you would like to store your program In other words a program number You re choices are 1 thru 6 Use the numerical keys to choose 2 Press the Enter key SEGS is displayed alon...

Страница 9: ...is complete the display alternates between CPLT current chamber temperature and total firing time Pressing the Start Stop key at this point will return the display to the IdLE Idle position On the Fl...

Страница 10: ...II allows you to add time to a previously programmed hold period This feature comes in handy when you desire to hold at temperature longer than what you initially programmed Using the Adding Time to...

Страница 11: ...ter firing data that gives a temperature along with how long it should take to get there In these cases you must convert to degrees per hour The RampMaster II does allow for a rate of As Fast As Possi...

Страница 12: ...t are minutes When the firing is started you will see the delay start amount displayed This time will count down to 0 00 at which time the firing will begin to run Writing over Previously Stored Data...

Страница 13: ...y will read a particular zone You will know which zone is being displayed as tC X X being 1 2 or 3 will be displayed For example if the display reads tC 2 during firing the temperature being displayed...

Страница 14: ...aster II s may be connected The ID feature is used to identify the particular RampMaster II kiln To Use the ID Feature Press the OTHER key until Id is displayed Press the Enter key Use the numerical k...

Страница 15: ...nd normal 6 program 8 segment operation is active Cone Offset The RampMaster II allows you to adjust offset the equivalent temperature used for the cone numbers This feature comes in handy when you wo...

Страница 16: ...ror 2 Chamber temperature too far above hold temperature 50 F above hold temperature Error 3 Chamber temperature too far below hold temperature 50 F below hold temperature Error 4 Chamber temperature...

Страница 17: ...ower thermocouple temperature 12 Your 4 digits would be 9012 Percent 4 When cycling through the OTHER menu selections you will see a prompt labeled as PCT4 The RampMaster II does not use this feature...

Страница 18: ...long with the time value counting down remaining hold time Display Reading a Decreasing Time Value Program is running with a delay start the time value counting down is the remaining delay start time...

Страница 19: ...13 CHG Change page 15 RA x Rate page 8 CNOS Cone Offset page 15 RSET Reset page 13 CONE Cone page 7 SEGS Segments page 8 CPL Complete page 9 SKIP Skip to Next Segment page 10 CPLT Firing Complete pag...

Страница 20: ...IdLE While Running a Program At Any Other Position Pressing once begins the Ramp Mode Programming Process No Function No Function RECALL PROG While at the Idle Position IdLE While Running a Program A...

Страница 21: ...ogram At Any Other Position Initiates the Cone Fire Mode Programming Process and Selects the 13 hour Preset Cone Fire Mode Program No Function No Function 10 HR While at the Idle Position IdLE While R...

Страница 22: ...ly loaded firing program data Pressing once displays the currently loaded firing program data No Function CONE TABLE While at the Idle Position IdLE While Running a Program At Any Other Position Initi...

Страница 23: ...nt Temperature Reserved Reserved 250 F 1000 F 1100 F Final Temp minus 250 F Final Temp Cool Down User Defined Hold Time Reserved Reserved 0 Min 0 Min 0 Min 0 Min 0 Min Not Used 7 Hour Generally Used f...

Страница 24: ...displays a corresponding Error Code describing the fault Pressing any key at this point displays the elapsed time and temperature at which the error occurred Make note of these values before clearing...

Страница 25: ...nter key one time during this condition removes the ERRP error code PF Extended Power Failure has occurred PF is displayed when the controller is powered up after an extended period of non use press E...

Страница 26: ...Short circuits occur when line voltage finds it s way to another line or ground They are usually violent occurrences with lots of noise flashes of light and maybe a bit of smoke During a short circui...

Отзывы: