7
HOSE AND REGULATOR:
Your grill is equipped with a Type 1 connection device with the following features:
1. The system will not allow gas fl ow from the cylinder until a positive connection to the valve has been made.
Note:
The cylinder valve and all grill burner knobs must be turned OFF before any connection is made or
removed.
2. A regulator fl ow limiting device, when activated, restricts the fl ow of gas to 10 cubic feet per hour. If the
fl ow limiting device is activated, perform Regulator Resetting Procedure.
Note: If your grill will not get hot enough to cook, the fl ow limiting device may have been activated.
CONNECTING HOSE AND REGULATOR:
1. Inspect the propane tank valve rubber seal for cracks, wear or
deterioration prior to use. A damaged rubber seal can cause a gas
leak, possibly resulting in an explosion, fi re or severe bodily harm. Do
not use a propane tank with a damaged rubber seal.
2. Attach or detach regulator to the LP gas cylinder only when cylinder is
at rest in tank holder.
3. Check that the cylinder valve is closed by turning the knob clockwise.
4. Check that the grill’s burner control knobs are in the “OFF” positions.
5. Visually inspect the hose assembly prior to each use for evidence of
damage, excess wear, or deterioration. If found, replace the assembly
before using your grill. Only the manufacturer’s supplied replacement should be used.
6. Remove the protective plastic cap from the cylinder valve.
7. Check that the hose does not contain kinks, does not contact sharp edges, and does not contact
surfaces that may become hot during use.
8. Hold regulator and insert the brass nipple into the LP cylinder valve outlet. Ensure that the device is
centered properly.
9. Turn the large coupling nut clockwise by hand and tighten to a full stop. Take care not to cross thread
the coupling nut onto the cylinder valve. Do not use tools to tighten connection.
Note: If you are unable to make the connection, repeat Steps 7 and 8.
10. Leak check all fi ttings before lighting your grill. See section on “Leak Testing” in this manual.
Note: To remove regulator from propane tank, turn off the tank valve and rotate the large coupling nut
counter-clockwise and remove.
REGULATOR RESETTING PROCEDURE:
If your grill will not get hot enough to cook, the fl ow limiting device may have been activated.
Mini Reset:
Turn ALL burner control knobs to “OFF”, turn off the cylinder valve. Wait one minute. Slowly turn
cylinder valve ON and relight grill. If burner fl ame is higher and grill heats up properly – proceed with
cooking.
Full Reset:
Turn ALL burner control knobs to “OFF”, turn off the cylinder valve. Disconnect hose and regulator from
cylinder. Wait two minutes, reattach hose and regulator and perform leak test.
WARNING
•
Never use your grill without leak testing all gas connections, hoses and propane tank. Follow
the section on “Leak Testing” in this manual for proper procedures.
LEAK TESTING:
Inspect Rubber Seal (see page 6)
Содержание GAS7540AS
Страница 22: ...21 ...
Страница 23: ...22 1 2 3 ...
Страница 24: ...23 4 5 ...
Страница 25: ...24 6 7 ...
Страница 26: ...25 8 9 ...
Страница 28: ...27 12 13 14 ...
Страница 30: ...29 19 20 ...
Страница 31: ...30 Even Embers GAS7540AS ...
Страница 53: ...52 ...
Страница 54: ...53 1 2 3 ...
Страница 55: ...54 4 5 ...
Страница 56: ...55 6 7 ...
Страница 57: ...56 8 9 ...
Страница 59: ...58 12 13 14 ...
Страница 61: ...60 19 20 ...
Страница 62: ...61 Even Embers GAS7540AS ...