PRECAUTIONS FOR ELECTRICAL CONNECTION
-If using an electrical or pneumatic screwdriver,
adjust the tightening torque
-If the device has been moved from a cold to a warm
place, the humidity may have caused condensation to
form inside. Wait about an hour before switching on
the power
-Make sure that the supply voltage, electrical
frequency and power are within the set limits. See
the section TECHNICAL SPECIFICATIONS
-Disconnect the power supply before doing any type
of maintenance
-Do not use the device as safety device
Connector 2
Number Description
USB port, for programming the device.
Micro-switch
Number Description
1
to terminate the RS485 Modbus network
001_EPJColor_Parete_AlimentazioneIndipendente_001_0.1_AZ
GND
+
-
+
-
+
-
7
6
5
4
3
2
1
EPJcolor
12
ON
12
ON
Device with
RS-485 port
RS-485
Micro-switch
230 VAC / 24 VAC 4 VA
safety transformer
Do not supply another
device with the same
transformer.
Electricity grid
230 VAC
Insertion of the RS-485 MODBUS port termination resistor
To insert the RS-485 MODBUS port termination resistor:
–
Place
micro-switch 2 in position ON
–
Place
micro-switch 2 in position OFF
The micro-switch is at the back of the device (remove the
back shell from the front before).
Electrical connection with independent power supply
Type
Description
Purpose of the control device
Function controller
Construction of the control
device
Built-in electronic device
Container
Black, self-extinguishing
Category of heat and fire
resistance
D
Dimensions
111,4 x 76,4 x 18,5 mm
Mounting methods for the
control device
wall mounting
Degree of protection provided
by the covering
IP30
Connection method
Fixed screw terminal for wires up to 1
mm² blocks
Maximum permitted length
for connection cables
Power supply: 10 m
RS-485 MODBUS port: 1,000 m (3,280
ft)
Operating temperature
-10 – 55 °C
Storage temperature
-20 – 70 °C
Operating humidity
Relative humidity without condensate
from 5 to 95%
Pollution status of the control
device
2
Compliance
- RoHS 2011/65/CE
- WEEE 2012/19/EU
- REACH (EC) Regulation N.
1907/2006
- RED 2014/53/UE
Power supply
24 VAC (±15%), 50/60 Hz (±3 Hz), max.
4 VA not insulated or 12... 30 VDC,
max. 2 W not insulated (independent
power supply or by a controller)
Earthing methods for the
control device
none
Rated impulse-withstand
voltage
I
Over-voltage category
330 V
Software class and structure
A
Clock
Incorporated secondary lithium
battery
Clock drift
≤ 55 s/month at 25 °C
Clock battery autonomy in the
absence of a power supply
6 month
Clock battery charging time
24 h (the battery is charged by the
power supply of the device)
Displays
Colour touch-screen TFT graphic
display
Alarm buzzer
Built-in
Communications ports
- 1 RS-485 MODBUS port
- 1 USB port
3.TECHNICAL SPECIFICATIONS
EVCO S.p.A.
Via Feltre 81, 32036 Sedico (BL) ITALY - Tel. +39 0437 8422 - Fax +39 0437 83648 - e-mail [email protected] - web www.evco.it
Questo documento e le soluzioni in esso contenute sono proprietà intellettuale EVCO tutelata dal Codice dei diritti di proprietà Industriale (CPI). EVCO pone
il divieto assoluto di riproduzione e divulgazione anche parziale dei contenuti se non espressamente autorizzata da EVCO stessa. Il cliente (costruttore,
installatore o utente finale) si assume ogni responsabilità in merito alla configurazione del dispositivo.
EVCO non si assume alcuna responsabilità in merito ai possibili errori riportati e si riserva il diritto di apportare qualsiasi modifica in qualsiasi momento senza
pregiudicare le caratteristiche essenziali di funzionalità e di sicurezza.