![EvaKool Travelmate TMDZ50 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/evakool/travelmate-tmdz50/travelmate-tmdz50_instruction-manual_2441546005.webp)
5
3. Operation
•
Power:
The refrigerator can be powered by a multi-voltage system utilizing either 12/24
Volts or 240 Volts . The electronic module controls the compressor motor and has the
added function of a three stage battery protection . When the input voltage drops below
the minimum, the compressor will cut out; when the voltage comes back up to the cut-
in value, the compressor will restart automatically .
•
Battery Protection:
The SECOP compressor requires approximately 11 .0 Volts (12 Volt
System) or 23 .0 Volts (24V System) to operate . If the voltage drops below this the fridge
will stop running .
•
Cable Specification:
The DC cables must have a suitable cross-section for their length
(measured from the battery to the unit), according to this table:
Cable Thickness (Area)
12V Max Cable Length
24V Max Cable Length
(mm
2
)
AWG
(m)
(ft)
(m)
(ft)
2 .5
13
2 .5
8
5
16
4
11
4
13
8
26
6
9
6
20
12
39
10
7
10
33
20
66