background image

7

4. Operation

Your EvaKool fridge is designed to operate at 3 speeds:
• 

High:

 3500 RPM - High product load, quick pull down.

• 

Medium:

 3000 RPM - Normal running.

• 

Low:

 2000 RPM - Only suitable for ambient temperatures 24°C and lower.

The higher the speed, the faster the compressor is operating which will enable the unit to 

cool/freeze quicker.
The lower the speed the more economical the unit’s operation and hence a lower power 

draw.

Temperature Setting Recommendations:

To run your Infinity Fridge as a dual temperature fridge/freezer, set at-16°C (freezer) 

and put the divider in place. The divider will permeate the cold air from the freezer and 

maintain a good temperature in your fridge compartment.
To run your Infinity Fridge as a fridge ONLY, set the fridge at 2°C and remove the divider.

Helpful Hint: 

When running your fridge as a dual temperature unit, if you require the 

fridge side to be colder, raise the divider up 10 to 20mm to allow more cold air from the 

freezer section to cool the fridge section.

Содержание ED

Страница 1: ...INSTRUCTION MANUAL FOR MODELS EVAKOOL RF ED INFINITY RANGE AUSTRALIAN OWNED AUSTRALIAN MADE FROM IMPORTED LOCAL COMPONENTS ...

Страница 2: ......

Страница 3: ...ing your EvaKool as it contains important information regarding your unit s operation maintenance care and terms of warranty This unit is designed to operate from either a 12V or 24V power source or from a 240V mains supply via an EvaKool approved 12V 24V 240V adaptor It can also be operated in remote areas from solar and generator power sources Please refer to page 4 for instructions All EvaKool ...

Страница 4: ...ease note The fridge is set to cut off immediately when the voltage drops below the sustainable level so as to protect your battery compressor and internal circuitry It will start automatically when adequate power is restored For maximum efficiency we recommend the fridge is installed on a level surface although if necessary it will operate on surfaces up to an angle of 30 IMPORTANT DO NOT block a...

Страница 5: ...he temperature setting or even switch the fridge off when it is not to be opened for lengthy periods eg overnight 12 Volt Operation The unit can also operate from a 240V mains power source via an EvaKool approved 12V 24V adaptor Connect the military plug end of the adaptor to the fridge and plug the 3 pin plug into the mains IMPORTANT NOTES DO NOT run your fridge near flames or sources of heat Pre...

Страница 6: ...he divider at the far end of the cabinet Set the required temperature To operate as a fridge freezer combo the divider can remain between the baskets or by removing the fridge section basket it can be moved within the cabinet thereby altering the size of both the freezer and fridge compartments Nylon Detachable Hinges Heavy Duty Suspension Fan Assisted Cooling Tunnel Nylon Moulded Handles Wide Ang...

Страница 7: ...nce a lower power draw Temperature Setting Recommendations To run your Infinity Fridge as a dual temperature fridge freezer set at 16 C freezer and put the divider in place The divider will permeate the cold air from the freezer and maintain a good temperature in your fridge compartment To run your Infinity Fridge as a fridge ONLY set the fridge at 2 C and remove the divider Helpful Hint When runn...

Страница 8: ...r faulty power supply If either of the above occur the circuit breaker will trip thereby cutting off all power to the unit As a result all the lights on the control panel will go out To reset simply push down the black button on the circuit breaker If after re setting the circuit breaker continues to trip please contact Evakool or your service agent See list of service agents supplied 5 Control Pa...

Страница 9: ... assist cleaning DO NOT FLOOD OR FILL THE CABINET WITH WATER DO NOT use sharp objects when cleaning and defrosting your EvaKool Keep your EvaKool clean by wiping both the interior and exterior with a damp cloth using a mild non abrasive household detergent and dry thoroughly Ensure fridge is completely defrosted and dry before turning back on Always clean the fridge after use and before storage St...

Страница 10: ... maintenance is easy to undertake In the case of RF models simply remove the 6 screws holding the compressor cover in place drop the cover forward and using a small brush vacuum or compressed air clean any dust or dirt from the condenser coils DO NOT USE WATER TO CLEAN THE CONDENSER COILS FAILURE TO REGULARLY CLEAN THE COILS MAY VOID THE WARRANTY If the unit is exposed to rain or water remove the ...

Страница 11: ...tomer inquiries are related to voltage drop which means the power to run the fridge is lost between the power supply the battery and the fridge compressor The fridge s compressor requires over 10 9 volts 12 volt and 22 7 volts 24 volt to operate If the voltage drops to these points or below the fridge will default you will hear the compressor trying to start every minute or so and the yellow fault...

Страница 12: ...power source vehicle or 240 volt adapter Electronic box fault Compressor fault 4 Flashes every 4 seconds Low Motor Speed Set to Low Speed Reduce products items inside unit Move so unit is in a lower ambient temperature Clean vents ensure clean air flow over compressor Fan fault 5 Flashes every 4 seconds Over Temperature Ambient temperature too high Clean vents ensure clean air flow over compressor...

Страница 13: ...transit Warranty repairs may only be carried out by an authorised service agent EvaKool will not reimburse repair claims carried out by unauthorised service agents Any tampering with any part of the unit by an unauthorised service agent will automatically void the warranty If a repair needs to be undertaken and is covered in terms of this warranty a warranty authorisation number must be obtained p...

Страница 14: ...14 ...

Страница 15: ......

Страница 16: ...For your nearest stockist contact EvaKool T 1300 865 665 E warranty evakool com or visit us at evakool com au ...

Отзывы:

Похожие инструкции для ED