3. Operation
•
Power:
The refrigerator can be powered by a multi-voltage system utilising either 12/24
Volts or with the included 240V adaptor. The electronic module controls the compressor
and has the added function of a three stage battery protection. When the input voltage
drops below the minimum, the compressor will cut out; when the voltage comes back
up to the cut-in value, the compressor will restart automatically.
•
Battery Protection:
The SECOP compressor requires approximately 11.0 Volts (12 Volt
System) or 23.0 Volts (24V System) to operate. If the voltage drops below this the fridge
will stop running.
•
Cable Specification:
The DC cables must have a suitable cross-section for their length
(measured from the battery to the unit), according to this table:
Cable Thickness (Area)
12V Max Cable Length
24V Max Cable Length
(mm
2
)
AWG
(m)
(ft)
(m)
(ft)
2.5
13
2.5
8
5
16
4
11
4
13
8
26
6
9
6
20
12
39
10
7
10
33
20
66
DOWN UNDER
SERIES II