3.Wiring diagram
Incorrect wiring could cause damage to the pressure controller,
confirm the color of the wires with the operation manual before wiring.
04
a. Single phase wiring connection
b. Three phase wiring connection-230V
c. Three phase wiring connection-380V
3 phase PUMP
M1
U V W
3
3W AC 230V
R S T
3 phase PUMP
M1
DPC-10
Controller
Gray
Brown
Blue
Black
U V W
3 4W AC 380V
R S T N
NFB
(MCCB)
AC 230V
M1
Coil
If connecting to a pump driven by 3ph/380V pump (Please
AC 110V,230V
NFB
(MCCB)
1
NFB
(MCCB)
L N
If installing DPC-10 with a varistor, please connect varistor wire in parralled with
thin Brown and Blue wires of the DPC-10.
*
note the power voltage must not exceed 400V.), the blue wire must not
connect to R or S wire, otherwise the DPC-10 controller will be burned out.
220V( <250V)
Note: If the voltage is over 250V, please add transformer by yourself.
DPC-10
Controller
Gray
Brown
Blue
Black
AC 230V
M1
Coil
DPC-10
Controller
Gray
Brown
Blue
Black
1 phase PUMP
WARNING
!
WARNING
!
WARNING
!
Any connection to the contactor, please add a
R.C capacitor (spark eliminator) to reduce the
possible electromagnetic interference.
WARNING
!
Beware of any connection to the contactor.
Please add a R.C. capacitor (spark eliminator) to
reduce the possible electromagnetic interference.
4.Button Function Introduction
Button Icon
Function
Browsing original pressure value.
Downward adjustment of the parameter value.
Pump start and stop operation
Upward adjustment of the parameter value.
Possible with Button
Short press once:
Switch to Basic parameter setting
Hold down the botton for 3 seconds:
Switch to Advance parameter setting
After entering the parameter setting,short press once again:
Switch to next setting mode and enter the set value
Long press for 6 seconds to Lock/Unlock the SET button for privacy.