Evac 6540372 Скачать руководство пользователя страница 3

EVAC reserves the right to make alterations to this specification without  prior notice. 

© Copyright Evac Oy. All rights reserved.

OPERATION & MAINTENANCE

Date: 06 Feb 2018

Doc. 000635-4

3

 

6540372 PUMP SE 044A 3 X 220V 50 HZ 

 

6540381 PUMP SE 044A 3 X 690V 60 HZ

6540369 PUMP SE 044A 3 X 380-420V 50 HZ   

6540371 PUMP SE 044A 3 X 230V 60 HZ 

6541600 PUMP SE 044A 3 X 690V 50 HZ 

 

6540370 PUMP SE 044A 3 X 460V 60 HZ

  

  

1) Lubricate the O-ring and the sealing surfaces with 

oil.

2) Cover the key way of the pump shaft with adhesive 

tape to avoid damage to the O-ring.

3) Push the rotating seal ring together with spring and 

retaining ring onto the shaft by using a suitable sleeve 

having inner diameter lightly bigger than 25 mm.

5.6 Assembly of rotating seal ring without assembly tool PUR 035

Assembly of rotating seal ring without a special tool is not recommended. However, if it must be done it must 

be ensured that spring compression is correct.