OPERATION & MAINTENANCE

Date: 06 Feb 2018

Doc. 000635-4

1

 

6540372 PUMP SE 044A 3 X 220V 50 HZ 

 

6540381 PUMP SE 044A 3 X 690V 60 HZ

6540369 PUMP SE 044A 3 X 380-420V 50 HZ   

6540371 PUMP SE 044A 3 X 230V 60 HZ 

6541600 PUMP SE 044A 3 X 690V 50 HZ 

 

6540370 PUMP SE 044A 3 X 460V 60 HZ

  

  

mechanical seal.

2. Start-up procedure

Clean the holding tank and pipework from any foreign objects. Fill the holding tank to the filling level before 

starting the pump. Follow the operation of the pump and check that it starts and stops as per in electric 

drawings.

3. Operation

During regular inspections check:

• that there are not alarms on

• that the pump does not make an unusual noise when running

• that the “running hours” meters of alternately running pumps show roughly the same reading

4. Maintenance

Evac SE 044A pump is specially designed to run together with Evac -ejector in heavy duty sewage conditions 

with minimal maintenance. The pump is equipped with Vortex impeller with no clearance adjustment, high 

quality mechanical seal and electric motor bearings for long life operation.

Once a year

Start pump manually and check that:

• 

 there are not leakages

• 

 pump is running smoothly

• 

 the ejector generates vacuum normally

• 

 alarms, valves etc. operate normally 

At 10 000 running hours (or every five years)

Dismantle the pump and:

• 

 clean pump housing

• 

 change mechanical seal (5451310)

• 

 change O-ring (5451330)

• 

 change electric motor bearings

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1. Installation

Install the pump to the base and ensure that no load is transferred 

to the pump from the pipework. Use suitable spacers between the 

pump and the base when necessary. Follow the instructions of the 

manufacturer of motor and make sure that cooling air is provided 

for the motor.

Adjust pipework on the suction and pressure side so that the flanges  

fit easily together. Make sure that fixing of bolts will not cause any 

load to the pump body. Connect the cable to the control panel as 

shown in the electrical diagram. Check direction of rotation to be 

clockwice by shortly starting the pump.

! NOTE:

 Do not run the pump dry for more than just a few seconds, because longer dry running will damage the 