background image

INSTRUCTION MANUAL 

PELLET INSERT 

2 DUCT INSERT 

EN 

Содержание IPCN11,5

Страница 1: ...INSTRUCTION MANUAL PELLET INSERT 2 DUCT INSERT EN ...

Страница 2: ... facilitate stove s ignition 6 Should any anomaly concerning the flame be detected or however in any other case NEVER SWITCH OFF the stove by disconnecting it from the mains Use the relevant button Disconnecting the stove from the mains will prevent exhaust fumes from being extracted 7 Should ignition phase take longer than expected due to damp or poor quality pellets generating excessive smoke in...

Страница 3: ...LLATION REQUIREMENTS 7 05 FLUE PIPE 8 06 INSTALLATION WARNINGS 10 07 INSTALLATION 12 08 PRODUCT USE 14 09 CONNECTIONS 18 10 CLEANING AND ROUTINE MAINTENANCE 19 11 NON ROUTINE CLEANING AND MAINTENANCE 19 12 TROUBLESHOOTING 20 13 YEARLY SCHEDULED MAINTENANCE 22 14 CERTIFICATE OF INSTALLATION AND TESTING 23 15 WARRANTY 24 ...

Страница 4: ... can be replaced only by the manufacturer or by its technical assistance service or by a similarly qualified person Do not place any object on the cable and do not bend it Avoid using extension cables as their temperature may increase excessively posing fire hazards Never use one single extension cable to power several appliances During normal functioning some parts of the stove may become extreme...

Страница 5: ...lly switched off It may take two separate ignitions to resume operation at ideal working conditions since the Auger tube is very long CAUTION If the stove is not properly installed power outages may result in fume spillages In some cases it may be necessary to install an uninterruptible power supply CAUTION Being a heating appliance some parts of the stove can become extremely hot For precisely th...

Страница 6: ...ments Requisiti minimi del tiraggio del camino Pa 11 12 Flue gas temperature Fume temperature C 162 3 91 4 Flue gas temperature at flue spigot or socket Temperatura uscita fumi C 180 8 111 6 Flue gas mass flow Flusso massico dei fumi g s 9 1 4 7 Efficiency Rendimento 89 5 93 5 Total heat output Potenza termica kW 11 5 5 3 Water heat output Potenza termica resa all acqua kW Space heat output Potenz...

Страница 7: ... flue pipe must be carried out in a workmanlike manner and according to European UNI 10683 and national regulations local regulations and the technical specifications and warnings contained in this Instruction Manual d The smoke outlet must be connected to the flue pipe by means of telescopic fittings e The diameter of the flue must be less than 150 mm f The connection to the flue pipe must be mad...

Страница 8: ...ant to high temperatures 1 000 C Should the existing flue opening not be perfectly perpendicular to the firebox fume outlet use an elbow to connect them The angle with respect to the vertical must never exceed 45 see figure to the side and there can be no bottlenecks No constrictions Use 10cm thick insulating thimbles if pipe vent passes through floors The flue pipe must be insulated along its ent...

Страница 9: ...fuel temperature due to an excess amount of oxygen wears down the combustion chamber sooner than expected On the other hand poor draught slows down combustion resulting in a decrease in the stove temperature fume spillage inside the room a loss of stove efficiency and dangerous build up in the flue pipe To avoid excessive draught it is advisable to use a draught regulator see figure on the side 05...

Страница 10: ...quate gaskets The air combustion socket must reach an external wall or a wall of an adjacent room with external ventilation as long it is not a bedroom or bathroom nor at risk of fire such as garages storage rooms combustibles stores etc These air vents must be made in such a way that they cannot be blocked either internally or externally and should be protected by a grille metal net or other suit...

Страница 11: ...temperature 1000 C Density 245 kg m3 Shrinkage at reference temperature 12 h 1 3 1000 C Cold crushing strength 1 4 MPa Bending strength 0 5 MPa Reversible thermal expansion 5 4x10 6 m mK EXAMPLES OF INSTALLATION EXAMPLES OF INCORRECT INSTALLATION Exhaust pipes must never be fitted pointing downwards or horizontally so that fumes are discharged directly through the external wall Specific heat capac...

Страница 12: ...de the area of irradiation of the product itself Also bear in mind that to avoid compromising correct operation of the appliance it is essential to create a recirculation of air inside its housing which prevents overheating This is possible by observing minimum distances and by creating ventilation holes 07 3 FUME EXHAUST CONNECTION When drilling the hole for the passage of the exhaust pipe it is ...

Страница 13: ...07 7 PROCEDURE FOR CORRECT PRODUCT INSTALLATION English 13 ...

Страница 14: ...s the information concerning the stove operating status A variety of data can be displayed and settings carried out according to the level of access by using the menu Depending on the selected mode and on their position on the display the data visualised may acquire different meanings PANEL DESCRIPTION Button P1 Increase When in programming mode use this button to modify increase the selected menu...

Страница 15: ...ect the desired channel number and keys Press the two buttons on the emergency console until all the LEDs flash At this point press OK on the remote control to confirm 08 4 MENU Press the P4 button to access the menu It includes several items and levels to access settings and control board programming USER MENU The table below briefly describes the menu structure focusing in particular on the func...

Страница 16: ...h the glow plug as indicated by the corresponding glow plug LED and the exhaust blower switch on Any problem detected during the switching on phase is indicated on the display and the stove goes into alarm status Loading with Pellets After approximately 1 minute the pellet loading phase begins and the message LOAD PELLET appears on the display During the initial phase the auger tube loads the pell...

Страница 17: ...ROBE EXHAUST 2 Fume probe faulty HOT EXHAUST 3 Fume overheating FNA FAILURE 4 Exhaust blower fault not working NO LIGHTIN 5 Stove does not ignite NO PELLET 6 Shutting down due to insufficient pellets THERMAL SAFETY 7 Safety thermostat activated NO DEPRESSURE 8 Depressor activated TRIAC COC FAILURE The auger tube turns continuously In case of alarm the stove is immediately switched off EXCEPT FOR T...

Страница 18: ...09 CONNECTIONS English 18 ...

Страница 19: ... a dry cloth to clean the stove Do not use abrasive material or products that could corrode or bleach surfaces At the end of the season with the last ignition the pellet remaining in the auger must be consumed completely The auger must remain empty to avoid clogging due to solidified sawdust residue created by moisture 11 NON ROUTINE CLEANING AND MAINTENANCE The purchaser must have the flue pipe a...

Страница 20: ...DE BURN POT CLEANING WARNING THAT APPEARS AFTER 8 HOURS OF STOVE OPERATION 4 5 KW MODELS ONLY 8 HOURS ARE CUMULATIVE TO CLEAR THE WARNING PRESS ALL 3 BUTTONS ON THE DISPLAY FOR 4 5 SECONDS IRREGULAR SLOW FLAME DIRTY GLASS ANTI EXPLOSION DEVICE PLUG MISSING OR NOT CORRECTLY POSITIONED PARTIALLY CLOGGED VENT PIPE CLEAN VENT PIPE IMMEDIATELY COMBUSTION AIR NOT SUFFICIENT SUCTION PIPE CLOGGED CLOGGED ...

Страница 21: ...OOR OPEN CLOSED INCORRECTLY LET THE STOVE COOL RE ARM THE MANUAL THERMOSTAT AT THE REAR RESTART THE STOVE CHECK THAT THE FIRE DOOR IS CLOSED CORRECTLY ALARM AUGER TUBE TRIAC THE BOARD DETECTS INCORRECT OPERATION OF THE PELLET LOADING MOTOR SWITCH THE STOVE OFF AND BACK ON CALL TECHNICAL ASSISTANCE ALARM ENCODER COC SCREW FEEDER MOTOR FAULTY OR BLOCKED CALL TECHNICAL SUPPORT T card C THE TEMPERATUR...

Страница 22: ...ance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ____________ Technical Assistance Centre stamp 10 CERTIFIES English 22 ...

Страница 23: ...n needed to correctly use operate and perform maintenance on the appliance CUSTOMER Signature DEALER INSTALLER Signature Copy of the dealer or installer CERTIFICATE OF INSTALLATION AND TESTING CUSTOMER _______________________________________ STREET ROAD ____________________________________________ CITY _________________________________________ POSTAL CODE __________________________________________...

Страница 24: ...of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness any small cracks or cracks that could be highlighted in ceramic majolica coatings any differences in shades and shades on ceramic majolica coatings door glass gaskets masonry works Eva Stampaggi S r l assumes no responsibility for damage to chrome fi...

Страница 25: ...nsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste disposal center or the retailer directly to get more information about places and ways of collecting Proper waste disposal is important not only for the environment and the health of citizens but also b...

Страница 26: ...n totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vorbehält ohne zu Vorankündigungen oder Ersetzungen verpflichten zu sein für opportun gehaltene Änderungen vorzunehmen Alle Rechte vorbehalten Der vollständige oder teilweise Nachdruck ist ohne die ausdrück...