04. PRODUCT USE
35
Stove switched off
The display will show the wording OFF. The fume fan stops working.
Stove re-ignition
It will be possible to switch the stove back on only at the end of the safety period of time set by Pr38 and if the fume temperature has
reached a value below Pr13.
What happens in case of...
Pellet ignition failure
If the pellets do not ignite, the display shows the alarm message “NO ACC” as shown in figure 25.
fig. 25
black-out
Pr48 = 0
When the power is resumed after an outage, the stove enters the FINAL CLEANING phase and waits until the fume temperature
reaches a value below Pr13.
fig. 26
Pr48 = T seconds
After a power outage, one of the following conditions may occur depending on the stove previous status:
previous status
black-out duration
new status
switched off
any
switched off
ignition
< T
ignition
pellet loading without pre-load
< T
pellet loading
pellet loading with pre-load
any
switching off
waiting for flame
< T
waiting for flame
working mode
< T
working mode
burn pot cleaning
< T
burn pot cleaning
switching off
< T
switching off
If the power outage duration is longer than T, the stove switches off.