background image

03. MINIMUM INSTALMENT REQUIREMENTS 

 

INTRODUCTION: 

 

INSTALLATION WITH WALL FUME OUTLET IS PROHIBITED.  INSTEAD THE FUME OUTLET MUST BE ROOF-TYPE AS PROVIDED FOR BY NATIONAL 

REGULATIONS. 

 

Eva stampaggi S.r.l. assumes no responsibility for injury to persons and/or damage to property caused by non-observance of the point highlighted 

above relating to non-compliant products installed. 

Install the stove according to the regulations in force in the country of use. 

 

In Italy, for example, this refers to UNI 10683: 2012, which refers to 4 areas: 

 

a. preliminary activities -

 are under the jurisdiction and are the responsibility of the reseller/installer at the time of the pre-installation inspection. Preliminary 

procedures include: 

  installation site suitability verification; 

  fume evacuation system suitability verification; 

  external air inlet suitability verification. 

At this stage, the product needs to be checked in order that it can be safely operated and that the relevant technical specifications are met. 

The safety conditions must be assessed with a preventive inspection. 

Stoves and fireplaces are heating systems and must be installed safely

 

and comply with the manufacturer's instructions!

 

 

b. installation -

 under the responsibility of the installer. In this phase the 

installation 

of the product and the smoke exhaustion system are considered as well as 

the handling of topics such as: 

 

safety distance

 from combustible materials; 

 

chimney flue construction

, smoke ducts, intubated systems and chimney cowls. 

 

c. issuance of supplementary documentation

 - the responsibility of the installer. 

The release of technical documentation must include: 

  manual of use and maintenance of the appliance and of the components of the system (e.g smoke ducts, chimney flue, etc.); 

  Photocopy or photograph of the chimney flue plate; 

  system manual: (if applicable); 

 

Declaration of Conformity in relation to Ministerial Decree 37/08

 

d. control and maintenance

 - the responsibility of the maintenance technician who must oversee protection and maintenance of the product during its operation 

over time.

 

The operator responsible for checking and maintaining the systems for winter and summer climate control carries out tasks in 

a workmanlike manner

 

and in observance of applicable regulations. The operator, at the end of these operations, must draw up and sign a technical inspection report in accordance with 

the models provided by the provisions of this decree and the implementing rules, in relation to the type and capacity of the system, to be issued to the person who 

signs a copy thereby confirming receipt and reading thereof". 

 

The Purchaser must not carry out any structural modification of the stove. 

Installation and connection must be carried out by the Purchaser and by qualified technical personnel, in compliance with European (UNI 10683) and national 

regulations, local regulations and assembly instructions contained in this Instruction Manual. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect, for damage to persons or property resulting from non-compliance with the 

aforementioned provisions of law, assembly instructions, warnings and general safety rules indicated in this Instruction Manual. 

Failure to comply with the installation requirements and/or tampering with the stove can cause: inadequate power and/or abnormal product behaviour, poor smoke 

draught, slow combustion, overheating and fire hazard of the stove, fire hazard of the flue duct, a lack of oxygen in the environment where the stove is located. 

Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage to persons or property caused 

by non-compliance with the requirements for installation of the stove and/or tampering with it. 

The Buyer must request and retain the certification of compliance of the installation, and the connection of the stove, with the provisions of law. In the absence of 

such certification Eva Stampaggi S.r.l. assumes no criminal and/or civil liability, direct and/or indirect for the malfunction of the stove and for damage caused to 

persons or property, resulting from the use of the product. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Содержание 12.5KW

Страница 1: ...INSTRUCTION MANUAL WOOD BURNING STOVES 8 KW 8 5 KW 12 5 KW EN...

Страница 2: ...CHARACTERISTICS p 7 04 3 CHIMNEY COWL p 7 04 4 DRAUGHT p 8 04 5 STOVE EFFICIENCY p 8 05 FUEL p 8 06 INSTALLATION WARNINGS p 9 06 1 HERMETIC STOVE p 9 07 INSTALLATION p 9 08 USER FUNCTIONS p 10 09 CLEA...

Страница 3: ...t use the stove in dusty environments or wherever inflammable gases are generated e g in a workshop or garage The stove that is covered by or in direct contact with flammable materials including curta...

Страница 4: ...protection and maintenance of the product during its operation over time The operator responsible for checking and maintaining the systems for winter and summer climate control carries out tasks in a...

Страница 5: ...tures 1000 C If the entrance to the existing chimney is not perfectly perpendicular to the smoke outlet of the firebox their connection must be made using the dedicated inclined fitting Inclination mu...

Страница 6: ...e chamber and external coating in lightweight concrete Optimal efficiency Traditional clay flue pipe with cavities Optimal efficiency Avoid flue pipes with internal rectangular section whose ratio bet...

Страница 7: ...4 3 CHIMNEY COWL A properly installed chimney cowl ensures optimum stove functioning The anti downdraught chimney cowl consists of a number of components whose outlet section sum always doubles the fl...

Страница 8: ...e the the colder are residual fumes from combustion and as a result the lower the draught A traditional fireplace of approximate design and insulation works much better when used with a traditional op...

Страница 9: ...the same height of the pipe located on the stove back When it is operational the stove can cause a negative pressure in the room where it is installed Therefore there should not be other naked flame...

Страница 10: ...ment should be well ventilated Open doors and windows in order to obtain an air current that frees the room from odours It is also possible that the product may undergo slight deformations as the stru...

Страница 11: ...the stove can cause operating anomalies clogging of the pipes inefficient or slow combustion overheating of the stove and catching fire of the same Eva Stampaggi S r l assumes no criminal and or civil...

Страница 12: ...t maintenance ____________ ____________ Technical Assistance Centre stamp Date 2nd maintenance ____________ ____________ Technical Assistance Centre stamp Date 3rd maintenance ____________ ___________...

Страница 13: ...________ Serial number _____________________ Year ____________ Dealer Stamp Installer stamp First name __________________________________________ Last Name __________________________________________ A...

Страница 14: ...ferences related to the natural characteristics of the coating materials are excluded from the warranty the grains of the stones that are the main characteristic and that guarantee their uniqueness an...

Страница 15: ...sponsibility for such disposal is to be borne by the owner and to not incur sanctions or adverse effects on the environment and health we recommend you contact the local administration the local waste...

Страница 16: ...tion totale ou partielle sans autorisation expresse de Eva Stampaggi S r l est interdite Die angegebenen Daten und Eigenschaften binden das Unternehmen Eva Stampaggi S r l nicht das sich das Recht vor...

Отзывы: