background image

COMMAND_CLASS_VERSION,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_V3,
COMMAND_CLASS_MANUFACTURER_SPECIFIC,
COMMAND_CLASS_POWERLEVEL,
COMMAND_CLASS_CONFIGURATION,
COMMAND_CLASS_NOTIFICATION_V8,
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

ZW97 protocol Endpoint 1 

Full Command Class Node Info 

COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2

The Below listed Command Class are all supported the Security S2

COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,

ZW97 protocol Endpoint 2 

Full Command Class Node Info 

Full Command Class Node Info 

COMMAND_CLASS_ZWAVEPLUS_INFO,
COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,
COMMAND_CLASS_SUPERVISION,
COMMAND_CLASS_SECURITY,
COMMAND_CLASS_SECURITY_2

The Below listed Command Class are all supported the Security S2

COMMAND_CLASS_ASSOCIATION,
COMMAND_CLASS_ASSOCIATION_GRP_INFO,
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_SWITCH_BINARY,

Z-Wave Configuration Parameters

 1:Status LED Configuration
      Paramter No: 1(0x01)     Size:1 Byte    Value: 00(default)   outlet on,led on.
                                                                        Value: 01                outlet on,led off.
                                                                        Value: 02                led no work.
2:Count Down Configuration(Turn off the output by time)
      Paramter No: 2(0x02)     Size:2 Byte    Value: xx xx  Turn off left outlet(Turn off Endpoint1 outlet)
        Value Scope :0----36000S  (default:00 00  no timer)
      Paramter No: 3(0x03)     Size:2 Byte    Value: xx xx  Turn off right outlet(Turn off Endpoint2 outlet)
        Value Scope :0----36000S  (default:00 00  no timer)

You may use the below configuration parameters to change settings of the corresponding functionality.

Support for Association Groups

ZW97 supports 3 association groups. A maximum of 5 node ID’s (nonmulti-channel devices) can be assigned to these association groups.