background image

 

5. LED Indicators 

On the front panel of UVE7312-MSPD, there are four LED indicators as the following 
 

POWER

:

  “

Green On

” indicates power is on and normal. 

 

DSL

:

 

Green On

” indicates VDSL is in connection. 

 

LAN

:

 

Green On

” indicates Ethernet is in connection. 

 

 

Flashing

” indicates Ethernet data activities.

   

 
M/S

:

 

On

” indicates selection of Slave mode. 

 

OFF

” indicates selection of Master mode. 

 
 

6.  Dip Switches Settings 

 

 

 

Pin 1 

Pin 2 

Pin 3 

Pin 4 

 

VTU-C/R Mode Rate 

Limit SNR 

OFF 

VTU-C Interleaved 

50/20 

Mbps  9dB 

ON 

VTU-R Fast 

Full 

Rate 6dB 

 
 

 

 

 

Pin 1

:  

VTU-C/R Switch

 

 
VTU-C:

    UVE7312-MSPD will act as at the Central Office (CO) side. 

 
VTU-R:

    UVE7312-MSPD will act as at the Customer Premise Equipment (CPE) or Remote side. 

 
 
 

 

 

Pin 2

Mode for impulse noise protection 

 

 

 

 

Interleave mode:

    Protection for up to 250ms impulse noises with latency less than 6 ms. 

 

 

 Fast 

mode:

   

Direct data transmission with latency less than 1ms. 

Содержание UVE7312-MSPD

Страница 1: ...1 Ethernet over VDSL2 PoE PD Converter UVE7312 MSPD User Manual Ver 1 02 Copyright EUSSO Technologies Inc All rights reserve ...

Страница 2: ...1 Table of Content 1 Introductions 2 2 Application Notes 2 3 Features 3 4 Packing Contents 3 5 LED Indicators 4 6 Dip Switches Settings 4 7 Data Rates Distances 5 ...

Страница 3: ...er over Ethernet PoE feature UVE7312 MSPD takes power supply over Ethernet cable from PoE Ethernet Switch and may work without external power adapter With plug and play features and minimum installation time each UVE7312 MSPD can be configured into either CO for central side or RT for remote side by dip switch setting The UVE7312 MSPD conforms to the ITU T G 993 1 and G 993 2 to meet VDSL VDSL2 an...

Страница 4: ...y impulse noise with a duration less than 250 us Interleaved mode has a maximum end to end latency of 10 ms Interleaved mode is the default mode Selectable fixed data rate and fixed SNR margin z User may select fixed SNR margin 9 dB or fixed target data rate z When fixed SNR margin is selected the systems will maintain the SNR margin at 9 dB across all available loop length z When fixed target dat...

Страница 5: ...F indicates selection of Master mode 6 Dip Switches Settings Pin 1 Pin 2 Pin 3 Pin 4 VTU C R Mode Rate Limit SNR OFF VTU C Interleaved 50 20 Mbps 9dB ON VTU R Fast Full Rate 6dB Pin 1 VTU C R Switch VTU C UVE7312 MSPD will act as at the Central Office CO side VTU R UVE7312 MSPD will act as at the Customer Premise Equipment CPE or Remote side Pin 2 Mode for impulse noise protection Interleave mode ...

Страница 6: ...SNR margin 9dB will result in less error with more stable VDSL link 6dB Original and Normal channel noise protection with 6 dB SNR 7 Data Rates Distances Performance in AWG 26 Line at 6dB with full rate Down Stream Data Rate Mbps Up Stream Data Rate Mbps Distance feet 100 60 500 98 53 1000 90 44 1250 80 36 1500 70 27 1750 60 18 2000 48 11 2500 39 8 3000 35 3 5 3500 28 0 3 4000 ...

Отзывы: