2. ADDING TO A ZIGBEE NETWORK
The device displays PA and a countdown from 99 starts. Press
or
button, to
start inclusion mode. If Comet Zigbee was added successfully, the LED display will show the
received Node ID.
3. MOUNTING ON RADIATOR
After adding (inclusion), the LED display shows an animation and the thermostat moves to
the mounting position. Then the LED display will show “Ad”.
1. Unscrew the old thermostatic head completely, loosen the fastening and pull it off the valve
2. If necessary, select a suitable adapter and mount it on the valve.
Customer Service:
Eurotronic Technology GmbH
Südweg 1
36396 Steinau-Ulmbach
Telefon: +49 (0) 6667 91847-0
E-Mail: [email protected]
Internet: www.eurotronic.org
NOTE:
ZIGBEE GATEWAY IS REQUIRED FOR COMMISSIONING.
For a more detailed installation and operation guide please visit:
https://eurotronic.org/service/downloads/
DELIVERY SCOPE
1 Comet Zigbee energy-saving radiator
3 Adapter (Danfoss RA, RAV, RAVL)
2 LR6/Mignon/AA batteries
1 Quick-Start-Guide
WARNING AND SAFTEY INSRUCTIONS
Safety Information:
Comet Zigbee is intended for indoor use. Operate Comet Zigbee only as
described in the user manual. Comet Zigbee should only be used in a dry and dust-free place
out of direct sunlight. Do not continue to operate the device if it shows obvious damage.
Comet Zigbee may not be rebuilt, modified or opened.
Warning instructions :
Never recharge, short-circuit or disassemble batteries - risk of ex-
plosion! Remove exhausted batteries from the device immediately. Protect batteries from
overheating - increased risk of leakage! Do not use used and new batteries together. If
necessary, clean batteries and device contacts before inserting. Keep batteries away from
children. Avoid contact with skin, eyes and mucous membranes. If you come into contact with
battery acid, immediately rinse the affected areas with plenty of clear water and consult a
doctor immediately.
CONTROL AND DISPLAY ELEMENTS
3. Screw the thermostat onto the valve or adapter by
turning the union nut clockwise.
NOTE:
Completely remove the connecting pieces of the
plastic adapter before you use one of the enclosed adap-
ters! For information about each adapter, see:
www.eurotronic.org/Service/FAQ.
Article
Comet Zigbee
EAN
4260012712438
Article number
700
227
Supply voltage
2 x 1,5V LR6/Mignon/AA
Connection
M30 x 1,5mm
Method of operation
Typ 1
Dimension
62 x 68 x 83 mm
Weight
230 g (incl. batteries)
Degree of protection
IP20
Degree of pollution
2
increase temperature
decrease temperature
Reset / Pairing mode
Button
Comet
Zigbee
EN
Quick Start Guide
LED Display
Meaning
Radio icon: Informs about radio connection and adding operations.
lights up = connected to server
not lit = no connection to the server
Pairing mode (Inclusion) active.
Delete mode (Exclusion) active.
Adaptation must get started.
Animation: Lights up while an adaptation is process.
Animation: Lights up when the key lock is activated/deactivated.
Lights up when the battery level is less than 15%.
Exclusion operation failed.
No valve movement possible
No valve detected
Closing point not detected
Inclusion operation failed.
4. ADAPTATION
and - Press and hold both buttons together for 3 seconds to start adaption.
Adaptation is carried out.
LEGAL INFORMATION
DECLARATION OF CONFORMITY:
Eurotronic Technology GmbH hereby declares that the Comet Zigbee radiator thermostat
complies with all applicable European Economic Area regulations of Directive 2014/53/
EU. The full text of the EU Declaration of Conformity is available at the following internet address:
https://eurotronic.org/service/downloads.
WARRANTY
The guarantee period is 24 months and begins on the day of purchase. Please keep the receipt as
proof of purchase. For other important warranty information, see:
www.eurotronic.org.
ENVIRONMENT PROTECTION:
Information on environmental protection and disposal can be found in the
detailed operating instructions: www.eurotronic.org/service/downloads
Subject to technical changes at any time. Compatibility data without guarantee.
®
START OPERATING
1. INSERT BATTERIES
TROUBLESHOOTING
Reason
Battery almost empty
Boiler water temperature OK?
– Valve does not open after the
summer heating break-cold?
Valve does not close comple-
tely. The closing point of your
valve seal may have shifted.
Due to an endless thread, the
pressure piece on the undersi-
de can fall out if the controller
has not been attached to the
valve.
Inclusion operation failed.
Adaptation is not possible.
Comet WiFi is not (correctly)
mounted on the radiator
Valve stroke too short or
battery power too low.
Valve movement not possible.
Exclusion failed
Solution
Change batteries
Correct the boiler water temperature.
Disassemble the Comet Zigbee. Move the valve
tappet back and forth several times by hand/tool.
Disassemble the Comet Zigbee.
Move the valve tappet several times by hand - an
adaptation may not be possible because your valve
may be calcified or the seal is no longer performing
its function.
Remove batteries from the device.
Insert pressure piece.
insert batteries.
Zigbee Controller not in inclusion mode or
out of reach.
Mount Comet WiFi correctly on the radiator.
If necessary, use the correct adapter.
Open and close the valve tappet by hand several
times or insert new batteries.
Make sure that valve pin is freely movable.
Is the device and the gateway as well, connected
to network?
Problem
Radiator
does not
get warm
Radiator
does not
get cool
Pressure
piece falls
out
C1, Er,
Er1-3
The error display can be cleared by pressing the
or
key