Delivery scope:
1 x Air Quality Sensor Z-Wave Plus
1 x Micro USB power supply
1 x Quick Start Guide
Note! Please check the scope of delivery for completeness and intactness.
SAFETY INSTRUCTION
- The Air Quality Sensor is designed for use in buildings.
- Operate the Air Quality Sensor only as described in the user manual.
- The Air Quality Sensor should only be put to use in a dry and dust-free place,
away from direct sunlight.
- Do not keep using the device when there is obvious damage.
- The Air Quality Sensor may not be rebuilt, modified or opened.
- The Air quality Sensor is not to be used as a gas measuring instrument.
WARNING! RISK OF INJURY!
Risk of fatal injury and accidents to infants and children! The packaging material
represents a risk of suffocation. Never leave children unattended when the
packaging material is nearby.
Produktbeschreibung
The Air Quality Sensor Z-Wave Plus provides a wide range of air quality data for
VOC in ppm (Volatile Organic Compounds) combined with the temperature (°C) and
humidity (%) as well as the dew-point (°C) and CO2-äquivalent.
Operating and display elements
Button
State
Meaning
Network
Press three times
within 1 second
Air Quality Sensor Z-Wave Plus will react to
inclusion or exclusion commands.
Network
Hold for 10 seconds
Factory resets the Air Quality Sensor Z-Wave Plus.
Color
State
Meaning
Red
Permanently illuminated
Air quality is bad. Ventilation recommended.
(LED signaling can be disabled via Configuration
Command Class).
Orange
Permanently illuminated
Air quality is average.
(LED signaling can be disabled via Configuration
Command Class)
Green
Permanently illuminated
Air quality is good.
(LED signaling can be disabled via Configuration
Command Class)
Red
Lights up for 5 seconds
A task has failed.
Green
Blinking
Network operation (join / leave) is executed.
Green
Lights up for 5 seconds
A task was completed successfully.
2x Red 3x
Green
Lights up one after the
other
The Air Quality Sensor Z-Wave Plus is reset to
factory default settings.
Power supply
Connect the Micro-USB cable and an AC adapter to the air quality sensor and to
a power outlet. For optimum performance, use the items supplied in their original
packaging.
IMPORTANT:
When using the air quality sensor, make sure that the sensor is not disconnected
from the power supply, because the first 12 hours of operation the sensor learns
your corresponding room profile and also resulting air quality variations via a self-
calibrating algorithm.
After these 12 hours, the sensor guarantees you precise measurement results.
If the power supply is interrupted, this calibration process starts again.
Please also make sure that the room, in which the air quality sensor is operated, is
ventilated vigorously at least once a week.
This is important for the learning algorithm of the sensor.
Air Quality Sensor Z-Wave Plus
Quick Start Guide
Note:
If the measured values remain high for a long time, manual recalibration may
be helpful. To do this, briefly interrupt the power supply. After 12 hours, the sensor
guarantees precise measurement results again.
Add Air Quality Sensor Z-Wave Plus to a Z-Wave network (Inclusion)
1. Start inclusion mode of your primary Z-Wave Controller.
2. Press the network button three times within 1 second.
3. While the inclusion is active, the LED is blinking green. If the inclusion was
successful the green LED will light up for 5 seconds. Otherwise the red led will
light up for 5 seconds to indicate failure.
Remove Air Quality Sensor Z-Wave Plus from a Z-Wave network (Exclusion)
1. Start Exclusion mode of your primary Z-Wave Controller.
2. Press the network button three times within 1 second.
3. While the inclusion is active, the LED is blinking green. If the inclusion was
successful the green LED will light up for 5 seconds. Otherwise the red led will
light up for 5 seconds to indicate failure.
Help and
Troubleshooting
The red LED lights up for 5 seconds: An operation has failed/was not completed
successfully.
- Make sure that the maximum range has not been exceeded and that there are no
obstacles in the path of the signal.
- Repeat the process if necessary.
Technical Specifications
Device description
Air Quality Sensor Z-Wave Plus
EAN
42 600 127 112 64
Article Number
700088
Supply Voltage
Power supply
Frequency
868,42 MHz
Output Power
+4dBm
Method of operation
Type 1
Dimensions (W x H x D)
68 x 68 x 17 mm
Weight
47,7g
Degree of protection
IP20
Degree of pollution
2
Technical modifications are subject to change. All descriptions for compatibility are without
engagement.
LEGAL NOTICE
Advice on environmental protection
From the date of implementation of European guidelines 2002/96/EC and
2006/66/EC, into national law, the following applies: Electric and electronic
devices and batteries may not be disposed of in household waste. The
consumer is obliged to return electric and electronic devices and batteries
to the public collection points established for them or to the point of sale. The
particulars of this are regulated by the applicable state laws. The symbol on
the product, operation instructions or packaging points to these provisions. You
make an important contribution to the protection of the environment by reusing or
recycling old equipment/batteries or making use of them in other ways.
Dispose of packaging
Dispose of the packaging according to type. Put cardboard and carton in
the waste paper collection, foils in the recyclables collection.
Declaration of Conformity
Hereby, Eurotronic Technology GmbH declares that the Air Quality Sensor
Z-Wave Plus is in compliance with Directive 2014/53/EU. The full text of the
EU declaration of conformity is available at the following internet address:
https://eurotronic.org/service/downloads/.
Warranty
The 24-months warranty period begins at the day of purchase. Please keep the
receipt as evidence of purchase. During the warranty period, defective radiator
thermostats may be sent to your dealer or the address above. Please ensure
sufficient postage is paid. A new or repaired device will then be sent to you free
of charge. No new warranty period begins with the repair or replacement of the
device.
After the warranty period has expired, you also have the option of sending the
defective device to the specified address with sufficient postage for repair.
Repairs after the warranty period have expired are subject to a charge. Your
statutory rights are not limited by this warranty.
Made in Germany
Note:
A detailed manual for installation and operation is provided online:
https://eurotronic.org/service/downloads/
Support and Contact:
Eurotronic Technology GmbH
Südweg 1 | 36396 Steinau-Ulmbach
Telefon: +49 (0) 6667 91847-0
E-Mail: [email protected]