background image

Delivery scope: 

1 x Air Quality Sensor Z-Wave Plus 

1 x Micro USB power supply 

1 x Quick Start Guide 

Note! Please check the scope of delivery for completeness and intactness.

SAFETY INSTRUCTION

- The Air Quality Sensor is designed for use in buildings.

- Operate the Air Quality Sensor only as described in the user manual.

- The Air Quality Sensor should only be put to use in a dry and dust-free place,  

   away from direct sunlight.

- Do not keep using the device when there is obvious damage.

- The Air Quality Sensor may not be rebuilt, modified or opened. 

- The Air quality Sensor is not to be used as a gas measuring instrument.

WARNING! RISK OF INJURY!

Risk of fatal injury and accidents to infants and children! The packaging material 

represents a risk of suffocation. Never leave children unattended when the 

packaging material is nearby.

Produktbeschreibung

The Air Quality Sensor Z-Wave Plus provides a wide range of air quality data for 

VOC in ppm (Volatile Organic Compounds) combined with the temperature (°C) and 

humidity (%) as well as the dew-point (°C) and CO2-äquivalent.

Operating and display elements

Button

State

Meaning

Network

Press three times

within 1 second

Air Quality Sensor Z-Wave Plus will react to 

inclusion or exclusion commands.

Network

Hold for 10 seconds

Factory resets the Air Quality Sensor Z-Wave Plus.

Color 

State

Meaning

Red

Permanently illuminated

Air quality is bad. Ventilation recommended.

(LED signaling can be disabled via Configuration 

Command Class). 

Orange

Permanently illuminated

Air quality is average.

(LED signaling can be disabled via Configuration 

Command Class)

Green

Permanently illuminated

Air quality is good.

(LED signaling can be disabled via Configuration 

Command Class)

Red 

Lights up for 5 seconds

A task has failed.

Green

Blinking

Network operation (join / leave) is executed.

Green

Lights up for 5 seconds

A task was completed successfully.

2x Red 3x 

Green

Lights up one after the 

other

The Air Quality Sensor Z-Wave Plus is reset to 

factory default settings.

Power supply 

Connect the Micro-USB cable and an AC adapter to the air quality sensor and to 

a power outlet. For optimum performance, use the items supplied in their original 

packaging. 

IMPORTANT: 

When using the air quality sensor, make sure that the sensor is not disconnected 

from the power supply, because the first 12 hours of operation the sensor learns 

your corresponding room profile and also resulting air quality variations via a self-

calibrating algorithm.  

After these 12 hours, the sensor guarantees you precise measurement results.  

If the power supply is interrupted, this calibration process starts again. 

Please also make sure that the room, in which the air quality sensor is operated, is 

ventilated vigorously at least once a week. 

This is important for the learning algorithm of the sensor.

Air Quality Sensor  Z-Wave Plus

Quick Start Guide 

Note:

 If the measured values remain high for a long time, manual recalibration may 

be helpful. To do this, briefly interrupt the power supply. After 12 hours, the sensor 

guarantees precise measurement results again.

Add Air Quality Sensor Z-Wave Plus to a Z-Wave network (Inclusion)

1.  Start inclusion mode of your primary Z-Wave Controller.

2. Press the network button three times within 1 second.

3.  While the inclusion is active, the LED is blinking green. If the inclusion was 

successful the green LED will light up for 5 seconds. Otherwise the red led will 

light up for 5 seconds to indicate failure. 

Remove Air Quality Sensor Z-Wave Plus from a Z-Wave network (Exclusion)

1. Start Exclusion mode of your primary Z-Wave Controller.

2. Press the network button three times within 1 second.

3.  While the inclusion is active, the LED is blinking green. If the inclusion was 

successful the green LED will light up for 5 seconds. Otherwise the red led will 

light up for 5 seconds to indicate failure.  

Help and 

Troubleshooting

The red LED lights up for 5 seconds: An operation has failed/was not completed 

successfully.

- Make sure that the maximum range has not been exceeded and that there are no 

obstacles in the path of the signal.

- Repeat the process if necessary.

Technical Specifications

Device description

Air Quality Sensor Z-Wave Plus 

EAN

42 600 127 112 64

Article Number

700088

Supply Voltage

Power supply 

Frequency

868,42 MHz 

Output Power

+4dBm

Method of operation  

Type 1

Dimensions (W x H x D)  

68 x 68 x 17 mm

Weight

47,7g

Degree of protection

IP20

Degree of pollution  

2

Technical modifications are subject to change. All descriptions for compatibility are without 
engagement.

LEGAL NOTICE

Advice on environmental protection

From the date of implementation of European guidelines 2002/96/EC and 

2006/66/EC, into national law, the following applies: Electric and electronic 

devices and batteries may not be disposed of in household waste. The 

consumer is obliged to return electric and electronic devices and batteries 

to the public collection points established for them or to the point of sale. The 

particulars of this are regulated by the applicable state laws. The symbol on 

the product, operation instructions or packaging points to these provisions. You 

make an important contribution to the protection of the environment by reusing or 

recycling old equipment/batteries or making use of them in other ways.

 Dispose of packaging 

Dispose of the packaging according to type. Put cardboard and carton in 

the waste paper collection, foils in the recyclables collection.

Declaration of Conformity

Hereby, Eurotronic Technology GmbH declares that the Air Quality Sensor 

Z-Wave Plus is in compliance with Directive 2014/53/EU. The full text of the 

EU declaration of conformity is available at the following internet address:  

https://eurotronic.org/service/downloads/.

Warranty

The 24-months warranty period begins at the day of purchase. Please keep the 

receipt as evidence of purchase. During the warranty period, defective radiator 

thermostats may be sent to your dealer or the address above. Please ensure 

sufficient postage is paid. A new or repaired device will then be sent to you free 

of charge. No new warranty period begins with the repair or replacement of the 

device. 

After the warranty period has expired, you also have the option of sending the 

defective device to the specified address with sufficient postage for repair. 

Repairs after the warranty period have expired are subject to a charge. Your 

statutory rights are not limited by this warranty.

Made in Germany

Note:

 

A detailed manual for installation and operation is provided online:  

https://eurotronic.org/service/downloads/

Support and Contact: 

Eurotronic Technology GmbH 

Südweg 1 | 36396 Steinau-Ulmbach

Telefon: +49 (0) 6667 91847-0 

E-Mail: [email protected] 

Internet: www.eurotronic.org

Отзывы: