4
EUROSAN SU ARITMA SİSTEMLERİ SAN. ve TİC. A.Ş.
Organize San. Bölgesi 2. Cad. No: 4/4 Y.Dudullu-Ümraniye/İstanbul
Tel: 0216 499 84 66-67-68-69
Fax: 0216 499 84 70
ASSEMBLY INSTRUCTIONS
Filter should be mounted on a flat surface with full hygiene. The maintenance works
related to the device should be realized in a suitable a comfortable environment.
A clearance enabling the easy replacement of the cartridges should be left on the
top
of filter. This clearance should be a little bit longer than the cartridges.
Inlet connection should done from top of the filter and outlet connection should done
from bottom.
By-pass line should be done to supply continous water while system in maintenance.
The precautions required fixing the inlet outlet connection lines of the filter and to
avoid water hammer should be taken.
TECHNICAL CHARACTERISTICS
Product Code Model
Flow
(m3/h)
Flow
m3/h
Cartridge
Cartridge
Dimensions
Connection
Diameter
Dimensions
Weight
CP
CN-CX Quantity
inc
inc
mm
kg
MM.SKM1.304 SKM 1
8
18
3
20
1 ½”
168X780
16
MM.SKM2.304 SKM 2
12
27
3
30
2”
168X1030
20
MM.SKM3.304 SKM 3
16
36
3
40
2”
168X1280
23
MM.SKM4.304 SKM 4
28
63
7
30
3”
273X1045
37
MM.SKM5.304 SKM 5
38
84
7
40
3”
273X1295
39
MM.SKM6.304 SKM 6
48
108
12
30
4”
329X1045
48
MM.SKM7.304 SKM 7
64
144
12
40
4”
329X1295
52
MM.SKM8.304 SKM 8
100
228
19
40
DN 125
400X1295
99
* Flow calculation has made according to 5 micron for CP cartridges, 50 micron for CN and
CX cartridges.