23
Minimum flow adjustment
Instructions for urban (G110, G120, G150.1) and methane gas (G20, G25)
1. Light the burner and bring it to the minimum position.
2. Remove the gas tap knob and turn the adjustment screw on the side of the tap
rod:
anti-clockwise to increase the gas flow
clockwise to reduce the gas flow
until a regular minimum flame is obtained.
3. Re-assemble the knob and verify burner flame stability (when quickly rotating the
hand from maximum to minimum position the flame must not shut off).
4. Repeat the operation on all gas taps.
Instructions for liquid gas (LPG: G30, G31)
Tighten the screw on the side of the tap, rod clockwise completely.
Warning: these tasks may only be carried out by a qualified technician, authorized by the
gas distributing company or authorized service center!
TECHNICAL INFORMATION (TABLE 1)
EDG-705IX
EDG-604IX
EDG-905IX
Appliance dimension (mm)
750
600
880
Operating voltage
220-240 V~, 50/60 Hz
Burner
A: Auxiliary burner (1,0kW)
SR: Semirapid burner (1,75kW)
R: Rapid burner (3,0kW)
MW: Mini-Wok burner (3,3kW)
TC: Triple Crown burner (3,8kW)
D: Dual burner (5,5kW)
Front left
A
MW
D
Rear left
SR
SR
-
Front central
TC
-
A
Rear central
-
-
SR
Front right
SR
A
SR
Rear right
R
SR
R
Category Gas usage
Natural Gas I2H ; LPG I3B/P30
Total Power (W)
11300
7800
13000
NOZZLE TABLE
Natural Gas I2H
LPG I3B/P30
Model No.
D
TC
MW
R
SR
A
D
TC MW
R
SR
A
EDG-604IX
-
-
128-T
-
97-Z
72-X
-
-
85
-
65
50
EDG-705IX
-
135-K
-
128-H3
97-Z
72-X
-
98
-
85
65
50
EDG-905IX
155-H3 / 75-H1
-
-
128-H3
97-Z
72-X
98 / 47
-
-
85
65
50
Содержание EDG-604IX
Страница 15: ...15 Instructions for use and installation Gas Hob ...
Страница 29: ...29 ...
Страница 30: ...30 ...