PART 2: SOFTWARE CONFIGURATION
99
110150-4002A
Updating Via the Web Interface
In the
Update URL
field, enter the network address URL (Uniform Resource Locator) from which an
update file may be downloaded. The address must be accessible through the default network
interface of the ZyWAN-G9 and must point to a file server location containing update files for the
ZyWAN-G9. Some examples of addresses which could be used are:
(HTTP download from
ip_address
which must be an
HTTP server, with the files existing in
pathname
)
--ftp-user=
username
--ftp-password=
password
(for FTP download from
ip_address/somepath
, using
username
and
password
)
If the
Update URL
field is left blank, the following default URL address will be used:
http://files.eurotech-inc.com/ESF/product_updates/eurotech/zywan_g9
Note:
The default URL address listed above should only be used with a standard ZyWAN-G9
software version, because only the
main branch of “standard” releases is stored in that
location.
Standard G9 will have a “Current Software Version” on the
Status
page with a
name something like: ZyWAN-G9_release-x.y.z
Customer-specific software releases will have a differently named software version, and
may have entirely different sets of update files. Therefore, trying to apply the standard
ZyWAN-G9 updates to customer-specific systems is likely to cause unpredictable results.
Take care to enter an appropriate
Update URL
before clicking the
Update ZyWAN
button.
The server location must contain the latest versions of the ZyWAN-G9 software release files, such as:
zywan_g9_releases.txt
ZyWAN-G9-update-
x.y.z
.star
When the
Update Zywan
button is pressed, the files are downloaded and installed. After the update is
complete, the ZyWAN-G9 will be rebooted automatically if needed.
If more than one update is available at the update site, all updates will occur in numerical order, one
after the other. This may require some time to complete, and may require multiple reboots in between
updates. The
Check Update Status
button may be clicked whenever the ZyWAN-G9 is available on a
network address, to check on the status of an in-progress update. A prominent warning message will
also be given on the
Status
and
Update
tabs, to warn the user that a software update has started but
not yet completed.
Note:
If the ZyWAN-G9 is rebooted in the middle of an update, there is a possibility that software
corruption of the file system can occur. Make sure the update process is finished before
removing power or rebooting.
Содержание 930150-4003R
Страница 13: ...Introduction 13 110150 4002A This page intentionally blank ...
Страница 14: ......
Страница 15: ...PART 1 GETTING STARTED 15 110150 4002A PART 1 GETTING STARTED ...
Страница 40: ...ZyWAN G9 User Manual 40 110150 4002A This page intentionally blank ...
Страница 41: ...PART 2 SOFTWARE CONFIGURATION 41 110150 4002A PART 2 SOFTWARE CONFIGURATION ...
Страница 106: ...PART 3 CONFIGURATION EXAMPLES 106 110150 4002A PART 3 CONFIGURATION EXAMPLES ...