EUROSTER 4010 

 INSTALLATION AND OPERATION MANUAL

 

4

 

 

If you want to set a set temperature between 18 

°C

 and 23 

°C

, you must set the "LO" 

value to 18 

°C and the "HI" 

value to 23 

°C

.  

 

Hysteresis/PWM (H) 

Two operational options of activating the heating algorithm are available: hysteresis or 
PWM. 
In the case of hysteresis, the device is activated based only on a difference between the 
preset  and  current  temperature.  The  parameter  determines  the  accuracy  of  room 
temperature  control.  You  may  set  the  hysteresis  between  0.2 

°C  and  10

 

°C,  and  the 

factory setting is 0.4 

°C.

 

Setting the value to 0.0 will put the thermostat into PWM mode.  
PWM  is  a  more  advanced  method  to  achieve  the  preset  temperature.  It  is  suited  for 
systems with underfloor water heating. It is used to limit room temperature fluctuations. 
Unlike in on/off controls the current status of  the transmitter depends not only on the 
current difference between the preset and measured temperature but also on the past 
changes of temperature. PWM operates with fixed parameters:  

 

Minimum relay activation time of 3 minutes,  

 

Number of cycles per hour - 4 

 

Operating range of the PWM algorithm of 0.7 

°C.

 

 

Temperature sensor correction (C) 

It is a  value added to  or  subtracted from the  measured temperature  value. It adjusts 
the  displayed  temperature  within  the  range  of  +/-  5 

°C.  The  function  is  convenient  if 

the thermostat is located in a slightly warmer or cooler area of the room.  

 

Reset (rEs) 

When you change the value from 0 to 1, the thermostat restores factory settings. 

 

Exit (ESC) 

Press the central button to make the thermostat exit the service mode. 
Exit the menu at any time by pressing the left "

” button of the knob. 

 

6.

 

SETTING TEMPERATURE 

Use “

” and “

” buttons to set the desired temperature value. Pressing one of the buttons for 

the first time turns on the backlight and repeated pressing adequately decreases or increases 
the temperature value with 0.1 

°C step of the change. Th

e longer the button remains pressed, 

the quicker the values change. Confirm the temperature change with the central button or wait 
until the set value stops flashing and is stored. The factory setting is 20 

°C.

 

7.

 

TEST MODE (tSt) 

In the test mode, you may check the main parameters of the thermostat. In order to enter the 
test mode press and hold the 

central and “ ” button for approximately 2 seconds. 

 

The following tests are available: 

 

internal sensor temperature measurement 

 

relay test - press the 

lower “ ” button repeatedly to switch the relay on/off,

 

 

backlight test 

 

press the upper “ ” button repeatedly to switch the backlight on/off

 

8.

 

SWITCHING THE THERMOSTAT OFF 

When the switch is moved, the thermostat goes into the frost protection mode.   icon appears 
on  the  display.  Frost  protection  ensures  that  the  heating  is  turned  on  only  to  prevent 

temperature dropping below 4°C.

 

9.

 

ERROR INDICATION 

OP 

 sensor missing or damaged 

SH 

 short-circuit of the sensor or a damaged sensor 

Err 1 

 internal error, remove and after a few moments reinstall the batteries 

 

 discharged batteries icon. 

 

 