12.2.

 

Selecting operating mode 

While holding the  "B"  button pressed, insert the  receiver into the plug socket.  Depending on 
the mode set, the green or red LED lights up. Each time the button is pressed, the operating 
mode changes. When you select the mode, the receiver restores operation. 

Green  -  normally  open  mode  (COM 

  NO).  It  is  the  mainly  used  operation  mode.  While  the 

device operation indicator is active, the output cables are shorted. 

Red 

  normally  closed  mode  (COM 

  NC).  While  the  device  operation  indicator  is  active,  the 

output cables are opened. 

Caution! The factory default setting is (COM-NO). 

13.

 

FIRST START 

When inserted into the plug socket, the receiver indicates the relay operating mode. A flash of 
green LED 

 normally open mode (COM-NO), a flash of red 

 normally closed mode (COM-NC). 

Any change in the status of the thermostat (switching the heating on/off) is made immediately 
by the receiver, while the confirmation that the radio signal is received from the transmitter is 
repeated every 15 minutes. 

13.1.

 

Radio signal strength 

The  radio  signal  strength  is  indicated  together  with  the  reception  of  the  transmitter  signal. 
Radio signal reception is indicated in green. LED flashing three times stands for a very strong 
range, twice for a strong range, and once for sufficient range.   

13.2.

 

No radio communication 

If the communication between the thermostat and the receiver is interrupted (e.g. discharged 
batteries)  and  if  this  condition  lasts  for  60  minutes  (no  response  from  the  receiver),  the 
receiver switches to the frost protection mode. The heating device will be switched on every 3 
hours  for  20  minutes  to  prevent  the  rooms  from  being  cooled  down.  At  the  time  of  re-
establishing  communication  (replacement  of  batteries),  the  receiver  will  automatically  switch 
the system off and resume operation. 
If there is no radio communication, the green LED flashes rapidly. 

13.3.

 

Continuous operation of heating device (MAN) 

In  the  event  of  a  system  failure,  it  is  possible  to  manually  switch  on  the  heating.  Move  the 
switch on the RX receiver to the MAN position. Such status is indicated by a rapid flashing of 

the red LED. In addition, after a moment the display of the thermostat shows "On I" and 

 

symbol. 

13.4.

 

Receiver signaling table. 

Function 

Signaling 

Pairing 

Blue 

Reception of radio signal 

Green 

Lack of signal 

Green 

 flashing 

The heating device is switched on 

Red 

Manual operation in heating mode 

Red 

 flashing 

The air-conditioning device is switched on 

Blue 

Manual operation in air conditioning mode 

Blue - flashing 

14.

 

MAINTENANCE 

Do  not  use  solvents  and  aggressive  detergents  to  clean  the  thermostat,  since  they  may 
damage the surface of the housing and the display. Clean the thermostat housing with a soft 
cloth. 

 

 

Содержание 4020TXRX

Страница 1: ...e of 5 C 35 C The thermostat is programmable in daily operating cycles 2 BASIC THERMOSTAT FUNCTIONS Does not require leading cable connections between the thermostat and the controlled device User fri...

Страница 2: ...Prior to mounting or dismantling the set make sure that the heating cooling system is de energized Voltages hazardous to life may be present on receiver output cables power supply phase voltage there...

Страница 3: ...rving the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base CAUTION Use only alkaline AAA batteries to power the thermostat Do...

Страница 4: ...hand button Press the right hand button again select comfort or reduced temperature Use buttons to set the desired temperature value confirm with the central button In order to disable the function ho...

Страница 5: ...ton Active interlock is indicated by displaying the icon The interlock is active after 10 minutes The interlock is disabled in the same way This function is not active by default Temperature sensor co...

Страница 6: ...ermostat and each receiver has a unique number that distinguishes it from others It is not possible for any thermostat not paired with the particular receiver to interfere with the operation of anothe...

Страница 7: ...ce for a strong range and once for sufficient range 13 2 No radio communication If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this conditi...

Страница 8: ...stat stand receiver 230 V 50 Hz plug socket Thermostat weight without batteries thermostat without batteries 120 g Receiver 170 g Frequency of operation 868 MHz Maximum power of transmission 25 mW War...

Страница 9: ...s and nature resulting from the possible presence of hazardous components in the equipment and batteries and inaccurate storage and processing of such equipment batteries and accumulators Households p...

Отзывы: