Engineer Reset (After an Alarm)
If the Reset Mode(s) has been programmed for Engineer follow the steps below to reset the
system.
1)
The user must first unset the system. Details in user manual.
2)
Enter the engineer code followed by RESET.
It should be noted that if the Tamper reset has been programmed for Engineer Reset the display
will show
for 3 seconds each time the user attemts to set the system. The proceedure ashown above is
used to Reset this condition.
Anti-Code Reset (After Alarm or Service Timer Lockout)
To effect an Anti-Code Reset the engineer will require either a ProDigi Programmer with
Anti-Code Generator or Anti-Code Software running on a P.C.
1)
Ask the customer to enter the user code and then press Full-Set.
2)
A four digit seed code will be shown by the display.
3)
Enter this seed code into either the Generator or P.C. Software an Anti-Code will be
given.
4)
Ask the customer to enter this Anti-Code. The system is now reset.
Note:
Service Timer Lockout will have been indicated to the user via Flashing tamper LED.
Two weeks notice would have been given prior to Lockout. Resetting this via Anti-Code
will give another two weeks service. A service visit should be arranged and the Service
Timer (option 30) should be re-programmed to the required number of weeks.
! ! Service Due !