background image

RELEASE ER2017_06_23

60

115

This document is property of Euroscreen Srl.

Any distribution, reproduction, copying or publication of this document is prohibited.

Installation and maintanance manual

Projector lift 

Mod. SI - 200

Use the screws and washers to mount the “L” form metal brackets to the left and 

right profile of the lift, as shown below.

4.2

 

INSTALLATION “L” FORM METAL CEILING   

 

MOUNTING BRACKETS

Inside each upper right and left structural pro-

file, there are four nuts to screw the screws to 

the “L” form metal brackets.

The drawing below indicates the recommended position where to mount the “L” 
form metal brackets. In this installation manual, we suppose an installation to a 

flat and horizontal ceiling made of concrete. 

Till the lift is not ceiling mounted, 

do  NOT  remove  the  polystyrene 

cubes  from  the  lift  structure  in 

order  to  keep  tension  onto  the 

steel cables.

Содержание SI-200

Страница 1: ...perty of Euroscreen Srl Any distribution reproduction copying or publication of this document is prohibited INSTALLATION AND MAINTANANCE MANUAL PROJECTOR LIFT SI 200 ORIGINAL INSTRUCTIONS IN ITALIAN L...

Страница 2: ...IPTION OF THE PROJECTOR LIFT 2 1 General description 2 2 Dimensions of closed projector lift 2 3 Dimensions of open projector lift 2 4 Mechanical specifications 2 5 Motor specifications 3 0 SAFETY STA...

Страница 3: ...e product The installation manual is composed from 1 0 General information 2 0 Projector lift description 3 0 Safety and residual risks 4 0 Installation 5 0 Out of order 6 0 Check register 1 2 MANUFAC...

Страница 4: ...ARNING This symbol is used in the safety warnings of this installation manual in order to indicate dangerous situations that in case of negligence can cause limited injuries or damages The symbol can...

Страница 5: ...f the faulty part component or part of the product excluding installing dismantling and transport costs of the component or of the entire product 1 7 2 The purchasing company is obliged to inform in w...

Страница 6: ...of this product and it has to be archived and used during the entire lifetime of the product 1 7 8 In case the lift is passed to a third party it is COMPULSORY that the user hands over to the third p...

Страница 7: ...on and maintanance manual Projector lift Mod SI 200 This lift is identified by product identification labels that indicate its essential technical specifications 1 8 PRODUCT IDENTIFICATION LABELS 1 8...

Страница 8: ...is property of Euroscreen Srl Any distribution reproduction copying or publication of this document is prohibited 1 8 2 Warning label n 01 This label reports the following information Near the lift s...

Страница 9: ...Srl Any distribution reproduction copying or publication of this document is prohibited Installation and maintanance manual Projector lift Mod SI 200 Position Warning label n 02 1 8 3 Warning label n...

Страница 10: ...users have to be instructed that the use of this machine has to be done conforming to the indications of this installation manual The lift has to be used specifically for what it is purposed that it...

Страница 11: ...AL DESCRIPTION Left structural profile 30x30 mm Fix pulley Ceiling mounting bracket 40x40x60 mm Closing plug for profile 30x30 mm Front structural profile 30x30 mm Braided steel cable covered with PVC...

Страница 12: ...rl Any distribution reproduction copying or publication of this document is prohibited The drawings here under 2 2 a 2 2 b indicates maximum dimensions of the closed lift The drawings here under 2 3 a...

Страница 13: ...x350 WxD 575x1964x554 WxHxD GRILL TOTAL DIMENSION MAXIMUM PROJECTOR DIMENSIONS NET WEIGHT OF THE PROJECTOR LIFT GRILL INTERNAL DIMENSION DIMENSION LIFT CLOSED MAXIMUM CAPACITY CABLE GATHERING SYSTEM i...

Страница 14: ...NTENANCE OR CLEANING OPERATION OF THE PRODUCT CHECK CAREFULLY THAT THE LIFT IS DISCONNECTED BEFORE ANY OPERATION Do not disassemble any safety device mounted on the product see chapter 3 2 Do not acti...

Страница 15: ...with two safety screws fixed one onto the bottom left profile and one onto the bottom right profile The safety screws are fixed in a specific position so that in case one or both steel cables break th...

Страница 16: ...uring the use of the lift please take care of areas that have residual risks for people or objects in case of incorrect use or evaluation error or inattention eluding the norms specified in this insta...

Страница 17: ...ther residual risks Do not lift up or down people or animals On the lift have to be installed videoprojectors only Do not mount more load under the lift than the maximum load specified on the warning...

Страница 18: ...document is prohibited User has to pay attention also to other factors that can influence the noise level of the product Among the others two of these factors are correct installation and careful main...

Страница 19: ...open the packaging please CHECK that it contains ALL the components below In case one or more components are missing please refer to the dealer you purchased the product from 4 1 PACKAGING CONTENTS 4...

Страница 20: ...Sliding brackets to support the false ceiling plate pcs 04 Threaded bars M6x25 cm for fixing the ceiling cover plate pcs 12 Nuts M6 for mounting the threaded bars to the sliding brackets pcs 4 Blind...

Страница 21: ...n below 4 2 INSTALLATION L FORM METAL CEILING MOUNTING BRACKETS Inside each upper right and left structural pro file there are four nuts to screw the screws to the L form metal brackets The drawing be...

Страница 22: ...in the most accurate way The ceiling has to be clean and flat Installing the lift perfectly level is IMPORTANT and ensures silent movement of the lift without any shaking jolting or friction that wou...

Страница 23: ...om the lift structure in order to keep tension onto the steel cables lift up the lift using proper safety devices aligning the brackets with the drilled holes Mount the lift to the ceiling using the s...

Страница 24: ...sired height in order to fix the video projector with suitable screws not supplied Pleasetakecarethattheprojector s centre of gravity is located in the middle of the plate In order to define the ideal...

Страница 25: ...0 IT IS ABSOLUTELY FORBIDDEN TO POSITION THE POWER CABLE OF THE LIFT IN THE RESIDUAL RISK AREA OF THE LIFT AS SHOWN IN THE DRAWING HERE AT THE RIGHT SIDE OTHERWISE THE CABLE CAN BE CUT DURING OPERATIO...

Страница 26: ...g screwdrivers remove the up down buttons Fig 2 Turn the upper tile of the switcher in order to remove it from the bottom tile The up down switcher supplied gives the possibility to be fixed to the wa...

Страница 27: ...t the mains tension is the same as the one indicated on the product identification label n 01 see 1 8 1 It is compulsory to connect the electrical connection of the lift also to earth 4 5 5 Any operat...

Страница 28: ...to lower the closed stop position Do not try to high the upper end stop because this will cause severe damages to the product and invalidate warranty on the lift Turn the screw on the motor shown on...

Страница 29: ...G THE FALSE CEILING TILE 4 7 1 The supplied components allow to install the lift inside a false ceiling Components to fix the false ceiling plate are listed in chapter 4 1 Fig D E F L1 and L2 These co...

Страница 30: ...or publication of this document is prohibited Sliding brackets to support the false ceiling plate Hex head screws M6x10 Threaded bars M6x25cm Nuts M6 4 7 2 Mounting The following drawings explain how...

Страница 31: ...t in order to fix correctly the false ceiling plate After fixing the threaded bars fig 04 and defined the right length the false ceiling plate can be mounted using two types of screws The following dr...

Страница 32: ...it is necessary to divide the plastic parts from the electrical components in order to waste them properly following the recycling norms As regards the mechanic parts of the lift it is suggested to d...

Страница 33: ...ck with the end user that projector lift and projection screen if this is the configuration operate in different times not at the same time and that while the first one is operating the other one is n...

Страница 34: ...g g m m a y a y Firma Signature Firma Signature DATA DATE DATA DATE Osservazioni Notes Osservazioni Notes Esito positivo Positive result Esito positivo Positive result Esito negativo Negative result E...

Страница 35: ...to positivo Positive result Esito positivo Positive result Esito positivo Positive result Esito negativo Negative result Esito negativo Negative result Esito negativo Negative result Esito negativo Ne...

Страница 36: ...to positivo Positive result Esito positivo Positive result Esito positivo Positive result Esito negativo Negative result Esito negativo Negative result Esito negativo Negative result Esito negativo Ne...

Страница 37: ...to positivo Positive result Esito positivo Positive result Esito positivo Positive result Esito negativo Negative result Esito negativo Negative result Esito negativo Negative result Esito negativo Ne...

Страница 38: ...to positivo Positive result Esito positivo Positive result Esito positivo Positive result Esito negativo Negative result Esito negativo Negative result Esito negativo Negative result Esito negativo Ne...

Страница 39: ...to positivo Positive result Esito positivo Positive result Esito positivo Positive result Esito negativo Negative result Esito negativo Negative result Esito negativo Negative result Esito negativo Ne...

Отзывы: