Z
Y
2
3
1
202202-561-ENG
User manual - Jetmix 100-70
P19
8. SETTING OF THE LEVEL SENSOR
1.
Place a piece of white paper in the JETMIX* tank (photo 1), 2 centimetres above the desired minimum
product level (diagram 2).
2.
Place a screwdriver on the level sensor (photo 3) until LEDs Y and Z flash rapidly (6 Hz). Remove the
screwdriver, the sensor is reset.
3.
Replace the screwdriver until LEDs Y and Z flash slowly (2 Hz), remove the screwdriver.
4.
Replace the screwdriver, LEDs Y and Z will freeze. Remove the screwdriver.
5. Repeat the previous operation once.
*This step can be done by filling the tank with product instead of the white paper.
When the product in the machine’s tank reaches the minimum level previously set, the mixer will restart (if
AUTO mode is activated - (light (L7) on)) until the tank is filled to the set level.
Once the set level has been reached, the mixer will run for a period of 25 seconds (mixing time). Depending
on the flow-rate of the JETMIX, increase or decrease the mixing time by following the procedure below.
SETTING THE MIXING TIME
1. Press MANU/STOP (7) and then ON/OFF (6) and keep both buttons pressed.
2.
Release only the MANU/STOP button (7), the light (L5) will flash.
NB: The ON/OFF button (6) must be held permanently until the end of the procedure.
3. Press once on MANU/STOP (7), the display (A2) indicates H02. Press MANU/STOP (7) a second time,
the light (L7) flashes and the display (A2) indicates 25 seconds.
4.
Use arrows (9) and (10) to set the new mixing time.
5.
Once the time has been set, press AUTO (8) to confirm the operation.
6. Release ON/OFF (6).
This operation must be carried out within 5 minutes after switching the mixer on, otherwise
the level sensor will be locked.