5. CLEANING PROCEDURE
1.
Open the drain valve (F) and empty the tank. If needed, add some water to flow out the remaining product.
2.
Rinse the tank with water.
3.
Close the drain valve, fill the tank with some soapy water and run the machine so the stator can be soaped.
(Caution : never use solvant for this operation because the stator would be deteriorated).
4. Stop the machine.
5. Dismantle the connector on the lance and on the pump.
6. Put the cleaning ball in the pump nose, then replace the hose on the pump.
7. Turn the machine on to make the ball go through the hose until it comes out.
8. Repeat operations 5 to 7.
9. Stop the machine.
10.
Take off the connector on the pump again and flush out the pump nose.
11. Clean the lance and the nozzle.
12. Pour some storage liquid into the tank, according to the recommended dilution on the bottle.
13.
Disconnect the machine from the power supply.
The direct projection of water under pressure onto the control panel has to be stopped at
the risk of water infiltration into the electric box. Proceed by simply cleaning with a humid
sponge.
Disconnect the machine from the power supply before any intervention.
Before unscrewing the hose, make sure it is not under pressure anymore.