201902-345B-ENG
User manual - DropPro 4P
P9
4. USE OF THE MACHINE
4.1. PREREQUISITES
•
The electric connection has to be 230 V - 16 A - 50 or 60 Hz with a 3 x 2,5 mm cable reel of 40m
maximum, completely unreeled.
• The machine must be coupled to a compressor.
4.2. STARTING UP
1. Once the machine is connected, connect the air hose on the inlet port (E).
2.
Press the "ON/OFF" button (A), the warning light lights up.
3. Remove the nozzle (F) from the lance (G), then open the lance.
4.
Set the flow-rate on 3 with the potentiometer (B).
5.
Set the (C) button on "MANU" to check that the machine is working correctly. The drive shaft at the
bottom of the tank shall turn.
6.
Switch back the (C) button to the «AUTO» position.
7.
Pour some product into the tank, then switch back the (C) button to "MANU" position.
8.
Wait until the product flows regularly to the lance.
9.
Switch back the (C) button to "AUTO" position.
10. Close the lance and replace the nozzle.
11. Connect the air hose to the lance.
12.
Switch on the compressor*.
13. When opening the lance, the machine starts running.
14. Start spraying.
*NB: the compressor must be plugged in alone on a 16 A minimum plug with a 3 x 2,5 mm cable reel of 40m
maximum, completely unreeled.
4.3. GRAIN SETTING
Large grain
High product flow-rate (to set from 1 to 10 with the potentiometer (B)).
Low air pressure (to set from 0 to 8 with the air regulator of the compressor).
Thin grain
Low product flow-rate.
High air pressure.