background image

 

Document ID:06080001 

Rev: B 

Technical Support: 800-626-6912 

Page 16 of 24

Crystal Clean

 Pipe-Free

®

 Spa -

 Operating Instructions 

Preparing the Pedicure Spa for Operation:

 

After the pedicure spa is installed and the plumbing and electrical connections are made, clean and 
disinfect the basin before initial use.  Rinse the basin by using the attached water sprayer.  Wipe the 
basin dry with a clean towel. 

To Operate the Pedicure Spa, Follow These Easy Steps: 
Adding Water to the Pedicure Spa Basin: 

1.  Close the drain by turning the chrome drain handle counter-clockwise until it stops. 
2.  Add water to the basin by lifting upward on the water faucet fill handle.  Turn the handle in a 

counter-clockwise direction for cold water or clockwise for warm water as indicated by the red 
(hot) and blue (cold) markings around the handle (CAUTION:  hot water can burn skin).  Continue 
to add water until the fill line is reached.  The fill line is indicated by the wavy (~~~~) line in the 
basin. 

3.  Turn the off water by pushing the handle downward and center. 

Operating the Crystal Clean

 Pipe-Free

®

 System: 

The Crystal Clean

 Pipe-Free

®

 System eliminates pipes and jets that can harbor harmful bacteria 

while at the same time delivering a soothing, quality foot massage.  This unique system is driven by 
an impeller that pulls water through the inlet cover and then forces the water outward through key 
massage zones in the footplate.  The end result is a soothing massage delivered to all areas of the 
foot:  front, back and bottom.   

 

To start or stop the whirlpool, depress the On/Off button labeled “Jets” (

NOTE:  An indicator light on 

the “Jets” button flashes when the footplate is improperly installed, or the basin contains no 
water.  As a result, the whirlpool will not function.  To fix, simply check that the footplate is 
securely fastened or add water to the basin

). 

 

Removing Water from the Pedicure Spa Basin: 

First, make certain the whirlpool jets are turned off by turning the On/Off switch counter-clockwise to 
the “Off” position. 

 

If the pedicure spa is hooked up directly to a floor drain, simply open the drain by turning the drain 
handle in a clockwise direction until it stops.  You should see the water level lowering as water exits 
the basin. 

 

If the pedicure spa is equipped with the optional Power Drain Pump (PDP) feature, open the drain by 
turning the drain handle in a clockwise direction until it stops.  Press the button marked “Drain” on the 
front panel.  The water level will lower as water is pumped out of the basin.  Turn the pump off by 
pressing the “Drain” button on the front panel once the basin is fully drained (

NOTE:  the PDP will 

automatically shut off after 2-1/2 minutes.  We recommend turning off the pump manually if all 
water has drained before automatic shut-off

). 

Warning: 

It is extremely important to follow the cleaning instructions located on the following page.  
Failure to clean the pedicure spa adequately can result in serious health issues for your 
clients as well as the nail technician.  Failing to clean your pedicure spa may also cause the 
pedicure spa to not work properly.  Please consult your local and state codes concerning 
pedicure chair cleaning for further requirements. 

Содержание Solace ALTERA

Страница 1: ...Document ID 06080001 Rev B Technical Support 800 626 6912 Page 1 of 24 FORTE ALTERA and PRIMA Solace Spas ...

Страница 2: ...on or maintenance negligence improper cleaning or other circumstances beyond EUROPEAN TOUCH s control NOT COVERED 1 Damage to pump parts and or motor parts due to obstruction in plumbing lines etc 2 Staining fading or discoloration of plastic surfaces due to exposure and or the use of harmful cleaning agents or chemicals 3 Staining fading or discoloration caused by improper or poor water additives...

Страница 3: ...912 Page 3 of 24 OWNERS MANUAL For Solace Whirlpool Pedicure Spa Models FORTE ALTERA PRIMA IMPORTANT INFORMATION Serial Number W O Number Installed by Installation Date Serial Number W O Number Note Vietnamese and Korean translations available upon request ...

Страница 4: ...e Free 9 Traditional Whirlpool With Jets 10 Specifications 11 Attaching the Seat Back 12 Unpacking the Cushions 13 Remote Control Configurations 13 Attaching the Cushions 14 Component Reference 15 Pedicure Product Guidelines 15 Crystal Clean Pipe Free Spa Operating Instructions 16 Crystal Clean Pipe Free Spa Cleaning and Disinfecting Procedures 17 Traditional Whirlpool With Jets Operating Instruct...

Страница 5: ...r information and local code compliance procedures that need to be followed when having your pedicure spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser See limited warranty regarding incidental or consequential exclusions page 2 Precautions Do not stand in the basin of the pedicure spa Excessive water temperature is dangerous and should...

Страница 6: ...ctrical codes A licensed plumber and licensed electrician must complete the applicable connections of the pedicure spa Location and Support Select a level location The floor structure beneath the pedicure spa must be capable of supporting the occupied pedicure spa For the seat back to fully recline the pedicure spa base must be mounted a minimum distance from the wall Forte model with full recline...

Страница 7: ...ments for Backflow Protection Devices and Systems in Plumbing Fixture Fittings is applicable to plumbing fixture fittings with outlets not protected by an air gap Included in the possible range of applications are fittings with hose connected outlets fittings with pullout spout hand held showers shampoo fittings and deck mounted fittings ASME A112 18 3M is now referenced in ASME A112 18 1M Plumbin...

Страница 8: ...Document ID 06080001 Rev B Technical Support 800 626 6912 Page 8 of 24 Dimensional Drawings Crystal Clean Pipe Free and Traditional Whirlpool With Jets ...

Страница 9: ...Document ID 06080001 Rev B Technical Support 800 626 6912 Page 9 of 24 Crystal Clean Pipe Free ...

Страница 10: ...Document ID 06080001 Rev B Technical Support 800 626 6912 Page 10 of 24 Traditional Whirlpool With Jets ...

Страница 11: ...s 12 31cm of space between pedicure spa and wall in order for seat to recline to its fullest extent Massage motor 12V AC Adapter included alternate voltages available Power source 110V AC 5 Amp 60 Hz GFCI Protected Caution Pedicure spa must be installed by a licensed electrician and a licensed plumber conforming to all local and national electrical codes Construction Linear Low Density Polyethylen...

Страница 12: ... of the chair Step 1 Remove the hitch and clevis pins located on the seat back mounting bracket on the back of the chair Step 2 Slide the seat bracket into the black end on the linear actuator and line up the holes Step 2 Line up the hole on the seat bracket with the hole on the cylinder end For Prima line up with second hole Step 3 Slide the clevis pin through the holes and secure by inserting th...

Страница 13: ...n Indicates that Roller Feature is Activated Area of Vibration Zone 1 Upper Zone 2 Lower Increase or Decrease Speed of vibrating massage Numerical Display shows intensity levels LEDs show type of FULL BODY Massage Select from 5 types of FULL BODY Massages as indicated by LEDs above Adjust intensities Up or Down Power On Off automatically selects 15 min timer Holding switch for over 3 seconds activ...

Страница 14: ... attached to the junction box Step 2 Attach the seat bottom to the chair bottom Make sure that the cushion is centered on the chair bottom The arms should be able to close without cushion interference Step 5 FORTE ONLY The remote control and power supply cord are taped together behind the chair Remove the tape and connect the cords from the cushion to these connectors Step 8 ALTERA VIBRATION ONLY ...

Страница 15: ... excessive foam It has been determined that products containing non dissolving abrasives such as sand and sea salts will not harm the internal component structure of your pedicure spa as long as the entire EUROPEAN TOUCH cleaning requirements are followed without deviation Oil based products may be used in your pedicure spa as long as the cleaning requirements are met Please use pedicure products ...

Страница 16: ...k and bottom To start or stop the whirlpool depress the On Off button labeled Jets NOTE An indicator light on the Jets button flashes when the footplate is improperly installed or the basin contains no water As a result the whirlpool will not function To fix simply check that the footplate is securely fastened or add water to the basin Removing Water from the Pedicure Spa Basin First make certain ...

Страница 17: ...OTE When replacing the footplate carefully align the mounting studs with the mounting holes Tighten each knob until snug Be careful not to over tighten as this can damage the Tee Knobs After Last Pedicure of the Day 1 Drain water from the pedicure spa by turning the drain handle to the Open position 2 Remove the drain cover as shown on page 21 Remove the impeller as shown on page 21 Remove all deb...

Страница 18: ...he Jet heads should not be positioned directly at the suction cover Doing so will create a noisy gurgling sound as air is being forced directly into water pipes Turn off the whirlpool jets by turning the On Off switch counter clockwise to its original starting position Removing Water from the Pedicure Spa Basin First make certain the whirlpool jets are off by turning the On Off Switch counter cloc...

Страница 19: ...mponent with low sudsing soap or detergent using a soft brush Disinfect the components as well as the areas behind them with an EPA registered disinfectant Follow your state board requirements for disinfecting Replace all components 4 Clean all the surfaces of the basin using low sudsing soap or detergent and a non abrasive brush Remove all visible residue from basin and then rinse with sprayer 5 ...

Страница 20: ...n If the adjustment cover is hard to turn slightly loosen the jet nozzle nut Step 5 Reverse steps to reassemble Removal Replacing Suction Cover Tools required Philips head screwdriver Check your state and local regulations for cleaning procedures Links to your state boards can be found on our web site at www europeantouch com Refer to the cleaning procedure page headed Traditional Whirlpool With J...

Страница 21: ... for cleaning reference Step 2 To remove the handle adapter place Phillips head screwdriver into upper slot to reach screw as shown in picture above Unscrew and then pull adapter forward Step 4 Picture with Drain Plunger removed shown for cleaning reference Removing Replacing Impeller Check your state and local regulations for cleaning procedures Links to your state boards can be found on our web ...

Страница 22: ...Document ID 06080001 Rev B Technical Support 800 626 6912 Page 22 of 24 History and Notes ...

Страница 23: ...Document ID 06080001 Rev B Technical Support 800 626 6912 Page 23 of 24 History and Notes ...

Страница 24: ... Technical Support 800 626 6912 Page 24 of 24 EUROPEAN TOUCH 8301 W Parkland Court Milwaukee WI 53223 Phone Number 414 357 7016 Toll Free 800 626 6912 Fax 414 357 6360 Web Site www europeantouch com Email info europeantouch com ...

Отзывы: