background image

 

70080000 Manual Sogno DreamWave Spa 

Rev A 

Revision Date: 25 March 2010 

Page 12 of 42 

 

Warning    

 

 

 

Do not use the chair with anything other than an AC 120 V power source. 

Ö

 

May

 

result in fire or electric

 

shock.

 

 

Do not use with any type of transformer device. 

Ö

 

May

 

result in damage to the product or electric shock.

 

 

Do not use if the power cord or plug(s) is damaged, or if the wall outlet is loose. 

Ö

 

May

 

result in electric shock, short circuit, or combustion.

 

 

Before each use, check for holes or tears in the cover of the back pad. Also, check the 
other parts for tearing. Stop using the chair immediately if you find even the smallest tear. 
Unplug the chair and contact the vendor for assistance. 

Ö

 

Using the chair with holes or tears in the covering could result in injury or electric shock.

 

 

Do not operate under blanket or pillow. 

Ö

 

May result in burns, fire,

 

electric shock, or injury to persons.

 

 

Do not use outdoors. 

Ö

 

May result in burns, fire, electric shock, or injury to persons.

 

 

Do not operate where aerosol (spray) products are being used or where oxygen is being 
administered. 

Ö

 

May result in burns, fire, electric sock, or injury to persons. 

 

 

Caution    

 

 

Before plugging the power cord into the wall outlet, make sure that the main POWER 
switch is set to OFF. 

Ö

 

May result in damage to the product or electric shock. 

 

Make sure that the plugs on the power cord are inserted fully into the cord connector and 
the wall outlet. 

Ö

 

May result in electric shock, short circuit, or combustion. 

 

Before using the chair for the first time, turn on all the switches in order as indicated in 
this manual to check that the chair is operating properly. 

 

Before using, raise the reclining seat back to its fully upright position. Then recline the 
seat back slowly to the most comfortable position, remembering to start off with a lighter 
massage. 

Ö

 

Starting with a deep massage can result in injury. Elderly people and persons with weak 
bones should be especially careful when selecting massage intensity. 

 

When sitting down in the chair, do so slowly, ensuring that the spinal rollers are in the 
correct position at either side of the spine. The backbone should lie comfortably between 
the rollers without having to turn or twist the body. 

 

If you will be using the chair after it has not been used for a long time, first read this 
Operating Manual again thoroughly and check if the chair operates properly. 

 

 

Do not use the product in any way not prescribed by the Operating Manual. Do not use 
the product together with any other therapeutic device or with an electric blanket. 

Ö

 

May result in injury or have a negative effect on health. 

 

Do not move the product while someone is in it. 

Ö

 

Accident or injury may result if the product tips over. 

 

Do not use with anything other than the accessories supplied with this product. 

 

Содержание sogno dreamwave

Страница 1: ......

Страница 2: ...K WARNING 10 SAFETY PRECAUTIONS 10 DISPLAY WARNINGS 10 TYPES OF SYMBOLS AND DESCRIPTION 10 SAFETY PRECAUTIONS INSTALLATION 10 SAFETY PRECAUTIONS BEFORE USE 11 SAFETY PRECAUTIONS DURING USE 13 SAFETY P...

Страница 3: ...MS 27 CHANGING COURSES 28 MANUAL SELECTION MODE 30 HOW TO OPERATE MANUAL SELECTION MODE 30 BASIC OPERATIONS 30 AIR MASSAGE 31 ROLLING 31 VIBRATION 31 VARIOUS ADJUSTMENTS 32 HOW TO OPERATE MANUAL SELEC...

Страница 4: ...Date 24 March 2010 Page 5 of 42 OWNERS MANUAL For Sogno DreamWave Spa IMPORTANT INFORMATION Serial Number Work Order Number Installed by Installation Date The serial number and work order number are...

Страница 5: ...H Water Fill Line Capacity 4 5 U S gallons Whirlpool pump motor 110V 1 6 HP 110V 60Hz Seat upholstery Polyurethane Power source 110V 10V AC 2 75 Amps 60 Hz GFCI Protected X Caution Pedicure spa must b...

Страница 6: ...5 types Automatic Shiatsu Point Locator Function included in some programs Vibration Massage Function Back 2 levels Min Approx 1650 times minute Max Approx 2350 times minute Seat 1 step Approx 4500 ti...

Страница 7: ...us person b Do not use on Insensitive skin Person with poor blood circulation Note Check the skin in contact with the heated area of the appliance frequently to reduce the risk of blistering 4 Excessi...

Страница 8: ...but should first consult their physician prior to receiving a pedicure If the client experiences any pain or discomfort discontinue the use of the pedicure spa immediately Your client s massage and pe...

Страница 9: ...ypodermis Persons with suspected acute neck sprain whiplash injury Persons with any of the following conditions should seek medical advice before using the chair Serious heart conditions Sensory impai...

Страница 10: ...shock Make sure that the plugs on the power cord are inserted fully into the cord connector and the wall outlet May result in electric shock short circuit or combustion Before using the chair for the...

Страница 11: ...etween the armrest and the chair Accident personal injury or damage to the chair may result if hands feet or objects are caught Do not use the heater continuously for two hours or longer May result in...

Страница 12: ...tage stop the chair immediately and set the main POWER switch to OFF Unplug the chair from the wall outlet Accident or injury may result if the chair is still in operating mode when the power resumes...

Страница 13: ...n it Do not remodel the chair Anyone other than an authorized service person must not repair or disassemble Contact the vendor For safety reasons if the power cord is damaged contact the vendor for re...

Страница 14: ...o not use any products containing a foaming agent this will cause excessive foam It has been determined that products containing non dissolving abrasives such as sand and sea salts will not harm the i...

Страница 15: ...or With state of the art technology Various Course Functions Healthcare programs and Well Being programs that allow you to select the optimal program according to your purpose and Manual Selection mod...

Страница 16: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 18 of 42 LOCATION DIMENSIONS CHAIR IS SHOWN IN THE FULLY BACK POSITION AND FULLY RECLINED...

Страница 17: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 19 of 42 COMPONENTS DESCRIPTION CHAIR COMPONENTS...

Страница 18: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 20 of 42...

Страница 19: ...in progress is displayed with both characters and symbols See next page ROLLER Buttons During Preset Programs roller shoulder positions can be adjusted using and immediately after the Shiatsu points a...

Страница 20: ...adjusting the roller speed in three steps during Kneading Tapping 1 and Kneading Tapping Width Button For adjusting the width of the rollers in three steps Rolling Button You can select from between F...

Страница 21: ...e chair is off the rollers are normally drawn back into the left and right sides of the upper part of the seat back Storage Position For safety reasons first check the positions of the rollers If they...

Страница 22: ...s of the Shoulder Massage Unit HOW TO USE THE CHAIR WITHOUT THE SHOULDER MASSAGE UNIT You can have your shoulders massaged by the rollers and not by the Shoulder Massage Unit by securing the Shoulder...

Страница 23: ...of the shoulder massage section turn the cover over and then attach the Shiatsu pads at any place where the Velcro is provided according to your preference For easy replacement of the Shiatsu pads rai...

Страница 24: ...air is set to ON If the Child Safety Lock is locked operation disabled during operation the heater will turn itself off SPEAKER ON THE REMOTE CONTROL Button Indication The sound from the speaker can b...

Страница 25: ...arch 2010 Page 27 of 42 PRESET PROGRAMS Eight automatic programs provide a variety of different massages to relieve fatigue With the Preset Program buttons you can choose your favorite program which w...

Страница 26: ...tensity of air massage is reset to its initial setting MED Back Vibe Button The intensity of a back vibration operation can be adjusted with the Back Vibe button located behind the panel of the remote...

Страница 27: ...int Locator starts locating Shiatsu points The Automatic Shiatsu Point Locator is not available during Full Body Air Program and DreamWave Program Note For accurate Shiatsu Point location always sit a...

Страница 28: ...ation is selected Operation Button Action Indication Forward Reverse Speed Width Up Down Intensity Kneading This performs kneading type of massage Each time the button is pressed forward direction rev...

Страница 29: ...rogram Operation Button Action Indication Width Up Down Full Rolling Rolling This performs stretching of the full or partial spine with only up and down movements of the rollers Each time the button i...

Страница 30: ...ring Partial Rolling the center position of the range of Partial Rolling can be adjusted If or is pressed during Full Rolling upward or downward movement is reversed SPEED BUTTONS Operation Button Ind...

Страница 31: ...n the power to the remote control is shut off However reclining of the seat back and ON OFF of the heater are still enabled CHANGING COURSES SWITCHING FROM MANUAL SELECTION MODE TO A PRESET PROGRAM Wh...

Страница 32: ...performing the procedures provided in subsection b 1 through 6 and after the last client each pipe free pedicure spa shall be cleaned and disinfected in the following sequential manner 1 Fill the basi...

Страница 33: ...RING FOR OTHER PLASTIC PARTS Soak a piece of soft cloth in lukewarm water in which a small amount of mild detergent has been added thoroughly wring it out and clean off any spots or grime Then wipe wi...

Страница 34: ...0 Bulkhead Fitting 2 64 25022014 Escutcheon 1 22 06130087 Washer 7 8 Red 1 65 30040200 Motor 1 23 06130088 Washer 7 8 Blue 1 66 12130035 Screw 1 4 20x1 2 16 24 15130016 Check Valve 4 67 12130048 Nut 1...

Страница 35: ...70080000 Manual Sogno DreamWave Spa Rev A Revision Date 25 March 2010 Page 37 of 42...

Страница 36: ...Verify motor is plugged in to gray control box 3 Verify fuse in the gray control box is in tact 4 Verify the wires to the button are not cut 5 Remove clean touch assembly and verify the impeller is i...

Страница 37: ...if the power cord is fully plugged into the wall outlet 6 Check if the power cord is fully plugged into the power connector located at the rear of the chair 7 Check if the main POWER switch at the rea...

Страница 38: ...ere with your movements when getting out of the chair To continue massaging press the POWER button on the remote control again THE RIGHT AND LEFT ROLLERS ARE OUT OF ALIGNMENT The rollers are designed...

Страница 39: ...e the intensity by removing the buffer pad located at the rear of the back pad HOW DO I MAKE THE MASSAGE LIGHTER During Preset Programs adjust the intensity of massage with the BACK 3 D AIR LEVEL Back...

Отзывы: