background image

 

Содержание Clean Touch Self Contained Drop-In Spa

Страница 1: ......

Страница 2: ...damage To the Pedicure Spa or any components or part if altered or modified in any way To any expenses incurred by the Customer or any third party including labor or material during investigation rem...

Страница 3: ...erable European Touch shall not be liable for any other obligations or liabilities including but not limited to obligations or liabilities arising out of breach of contract or warranty negligence or o...

Страница 4: ...port 1 800 626 6912 Page 4 of 16 OWNERS MANUAL For Clean Touch Drop in Spa IMPORTANT INFORMATION Serial Number Work Order Number Installed by Installation Date The serial number and work order number...

Страница 5: ...TANT SAFETY INSTRUCTIONS 6 DANGER 7 WARNINGS 7 IMPORTANT REQUIREMENTS 8 HEALTH RISK WARNING 8 PEDICURE SPA SPECIFICATIONS 9 COMPONENT REFERENCE 10 REMOVING AND REPLACING IMPELLER 11 PEDICURE PRODUCT G...

Страница 6: ...o 6 30 PM CST After hours calls are recorded and attended to the next business day IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance basic precautions should always be followed includin...

Страница 7: ...rculation Note Check the skin in contact with the heated area of the appliance frequently to reduce the risk of blistering 4 Excessive water temperature is dangerous and should be checked before use M...

Страница 8: ...edicure spa installed Subsequent inspections and approvals that may be required are the responsibility of the purchaser See limited warranty regarding incidental or consequential exclusions page 2 HEA...

Страница 9: ...ater massage channels no closed loop circulating pipes fully drained easy to clean and sanitize Electrical switches On Off membrane switch for motor control and optional power drain pump Compliances D...

Страница 10: ...10 of 16 COMPONENT REFERENCE On Off Button On Off Drain Button as with PDP option Note Pressing with finger nails rather than the pads of fingers will damage the on off switch and will not be covered...

Страница 11: ...in our pedicure spas However the following guidelines can be used It is your responsibility to understand and follow your state s regulations regarding product cleaning and disinfecting requirements...

Страница 12: ...ected brush to remove all visible residue then reinsert impeller footplate and other components 4 Refill the basin with water and circulate the correct amount read the label for mixing instructions of...

Страница 13: ...Document ID 31080001 Rev B Technical Support 1 800 626 6912 Page 13 of 16 PEDICURE SPA CLEANING LOG SHEET Sample Pedicure Spa Date Time Initials After Client End of Day Weekly...

Страница 14: ...Document ID 31080001 Rev B Technical Support 1 800 626 6912 Page 14 of 16 REPLACEMENT PARTS BASIN ASSEMBLY...

Страница 15: ...ANNING MOTOR NEXT GENERATION 1 9 15000006 GASKET DRAIN ASSEMBLE 3 30 30151200 DRAIN KIT ASSEMBLY 1 10 12000216 I GLIDE BUSHING LEG REST ARM 2 31 30010241 HOUSING INLET ASM PEARL DUAL LOCK 1 11 2502200...

Страница 16: ...EUROPEAN TOUCH 8301 W Parkland Court Milwaukee WI 53223 Phone Number 1 414 357 7016 Toll Free 1 800 626 6912 Fax 1 414 357 6360 Web Site www europeantouch com Email info europeantouch com...

Отзывы:

Похожие инструкции для Clean Touch Self Contained Drop-In Spa