European Home Gas Stones Vent Free Скачать руководство пользователя страница 1

GAS STONES VENT FREE with FUSION BASKET

Installation, Operation and Owner’s Manual

Do not store or use gasoline or other 

flammable vapors and liquids in the vicinity of 

this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.
•  Do not touch any electrical switch; do 

not use any phone in your building.

•  Immediately call your gas supplier from 

a neighbor’s phone. Follow the gas  

supplier’s instructions.

•  If you cannot reach your gas supplier, 

call the fire department. Installation and 

service must be performed by a qualified 

installer, service agency or the gas 

supplier.

Installation and service must be performed by 

a qualified installer, service agency or the gas 

supplier.  

WARNING: If the information in these 

instructions is not followed exactly, a fire 

or explosion may result causing property 

damage, personal injury or loss of life.

This is an unvented gas-fired heater. It uses air 

(oxygen) from the room in which it is installed. 

Provisions for adequate combustion and venti-

lating air must be provided. Refer to page 6.

INSTALLER:  Leave this manual with the heater.

END USER: Retain this manual for future 

reference.

This heater may be installed in an aftermarket, 

permanently located, manufactured (mobile) 

home, where not prohibited by local codes.
This heater is only for use with the type of gas 

indicated on the rating plate. This heater is not 

convertible for use with other gases.

Report Number 284-L-04-5

Nov. 2014

Содержание Gas Stones Vent Free

Страница 1: ...vice must be performed by a qualified installer service agency or the gas supplier WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and venti lating air must b...

Страница 2: ... 3 Specifications and Dimensions 9 Fireplace Requirements 12 Installing the Burner 14 Gas Supply 14 Stone Configuration 16 Operating Instructions 18 Maintenance 20 Troubleshooting 21 Parts List 23 Warranty 24 Programming the Remote Control Appendix A ...

Страница 3: ...ol compartments burners and circulating air passageways be kept clean 8 CARBON MONOXIDE POISONING Early signs of carbon monoxide poisoning are similar to the flu with headaches dizziness and or nausea If you have these signs obtain fresh air immediately Have the heater serviced as it may not be operating properly 9 The installation must conform with local codes or in the absence of local codes wit...

Страница 4: ...pliance 17 Unvented gas heaters emit moisture into the living area In most homes of average construction this does not pose a problem In houses of extremely tight construction additional mechanical ventilation is recommended 18 During manufacturing fabricating and shipping various components of this appliance are treated with certain oils films or bonding agents These chemicals are not harmful but...

Страница 5: ...room heater and to replace any part of the control system and any gas control which has been under water 23 This heater must not be used with glass doors in the closed position This can lead to pilot outages and severe sooting outside the fireplace 24 Never burn solid fuels in a fireplace where an unvented room heater is installed 25 Always have a fireplace screen in place when the appliance is in...

Страница 6: ...s defined as a space whose volume is not less than 50 cubic feet per 1 000 BTU per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms communicating directly with the space in which the appliances are installed through openings not furnished with doors are considered a part of the unconfined space UNUSUALLY TIGHT CONSTRUCTION IS DEFINED AS CONSTRUCTION ...

Страница 7: ...ing rooms with an open area between with the following dimensions L1 151 2 ft L2 12 ft W 12 ft H 8 ft x 1000 52 800 BTU Hr Example B If there were a door between the two rooms the calculation would be based only on the room with the heater x 1000 29 760 BTU Hr Will my space support a Gas Stones Vent Free with Fusion Basket Maximum BTU hr my space will support use formula above 1 __________________...

Страница 8: ...8 Listing Label for Gas Stones Vent Free Natural Gas Burner Manufactured by European Home Inc Malden MA 02148 781 324 8383 ...

Страница 9: ... ONLY Manifold Pressure 3 5 0 87 kPa Minimum Supply Pressure 4 0 1 0 kPa Maximum Supply Pressure 7 0 1 7 kPa Orifice Size 6 Port 55 DMS Input High Fire 39 000 BTU hr Low Fire 27 000 BTU hr Gas Stones with 24 Fusion Basket Gas Stones with 30 Fusion Basket ...

Страница 10: ...10 SPECIFICATIONS and DIMENSIONS A 12 00 17 84 0 62 5 38 2 16 6 70 17 84 3 08 1 00 12 00 5 38 3 31 3 08 3 31 10 61 11 23 Dimension A 24 30 ...

Страница 11: ...11 SPECIFICATIONS and DIMENSIONS 0 75 0 75 3 00 22 50 Room Rear of Fireplace Premise gas supply should terminate within shaded area shown on plan view above ...

Страница 12: ...with unvented gas logs When installed in a vented fireplace your Gas Stones Vent Free with Fusion Basket must sit fully inside the fireplace so that it properly drafts up the chimney flue In all cases be certain that the burner of your Gas Stones Vent Free with Fusion Basket is behind the fireplace lintel see Figure 2 WARNING Before installing in a solid fuel burning fireplace the chimney flue and...

Страница 13: ...NTEL CLEARANCES 12 0 5 0 Existing fireplace opening Top of existing fire place opening Combustible mantels may be no closer to the fireplace opening than the distances shown in the Figure 2a side view above Figure 2a ...

Страница 14: ...upply piping should have a separate gas shutoff valve and a 1 8 NPT plugged tapping up stream of the valve The Gas Stones Vent Free with Fusion Basket and its main control valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of psi 3 5 kPa GAS SUPPLY INSTALLING THE BURNER Figure 4 Place 4 AA batteries in the battery cas...

Страница 15: ...y water solution to all the fittings to check for gas leaks Never use a flame to test for leaks Ensure that the burner inlet tube is in the shutter box Place the Fusion Basket over the burner so the burner is centered in the opening in the Fusion Basket as in Figure 5 Slide the Battery Case beneath the Fusion Basket Figure 5 WARNING Failure to position the parts in accordance with these diagrams o...

Страница 16: ...embers begin by placing one layer of the embers evenly over the en tire burner top as shown in Figure 6 Sort your stones by size into sixteen small three medium and four large Place a row of six small stones along the rear edge of the burner as shown in Figure 7 Figure 6 S S S S S S Figure 7 Next place two large stones and three small stones on the burner as shown in Figure 8 Then place two medium...

Страница 17: ...M M S S M L S S L L L M M S S S S S S S S S S S S S The stones installation must be per these instructions This heater must use only the stones provided by European Home An excess amount of stones may adversely affect the performance of the heater All previously applied loose material must be removed prior to reapplication WARNING Figure 10 shows a completed installation of stones ...

Страница 18: ...s been under water Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result causing property damage personal injury or loss of life OPERATING INSTRUCTIONS RESETTING THE SYSTEM Synchronizing the Remote and Re...

Страница 19: ... you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 5 Press the OFF and LARGE FLAME buttons simultaneously Release the buttons once you hear a beeping noise This acoustic signal tells you that the start sequence has begun Further short signals will continue until main gas flows and the burner is lit If the pilot or burner does not light go back t...

Страница 20: ...room temperature carefully remove and clean the stones with a soft bristled brush Never use a vacuum cleaner to clean the stones Clean the burner surface with a brush Replace the components per the instructions starting on page 11 of this manual WARNING Failure to keep the primary air opening of the burner clean may result in sooting and property damage Inspecting the Chimney An inspection of the ...

Страница 21: ...ode as above 1 Push switch to ON position 2 Secure wire 3 Replace receiver and reprogram code as above 4 Straighten pins on 8 wire connector 5 Replace valve 1 Purge the line or start ignition several times 2 Check spark gap check wiring connec tion Check for spark in location along cable 3 Replace valve Do not over tighten the thermocouple POSSIBLE CAUSE 1 Receiver must learn new code 2 Dead batte...

Страница 22: ... the spade connector closest to the thermocouple and thermocouple tube itself The reading should be 21 30 mV 2 Replace thermocouple 3 Confirm regulator pressure and sizing Replace if necessary 4 Replace valve Do not over tighten the thermocouple 1 Replace batteries 1 Turn manual override knob to ON position see figure 4 2 Turn flame to high fire by pressing up button on remote control 3 Confirm re...

Страница 23: ...ner flames The flames should look similar to those in the picture above PARTS LIST Burner Module NG GS VF BM NG 01 Stone Kit V VF PK 01 Pilot Assembly V VF PA 01 Fusion Basket V SB 01 For replacement parts and customer service contact EUROPEAN HOME 1 781 324 8383 ...

Страница 24: ... PRODUCT INSTALLATION RECORD Installer Please complete this form Customer Please retain this information Purchased From Date of Purchase Installed By Date of Installation Fireplace Serial Number Fuel Type ...

Страница 25: ...t You are now able to use the remote control To increase the flame the LARGE FLAME button should be depressed Pressing the SMALL FLAME button on the handset will reduce the flame The main flame may be lowered all the way down until it is off leaving only the pilot ignited Fully Extinguishing the Appliance From any heat setting press the OFF button for a few seconds This will cause the burner to fu...

Страница 26: ...erature Select either the Temp MODE or the Temp MODE by briefly pressing the SET button Hold the SET button until the TEMP display flashes Set the desired temperature with SMALL FLAME or LARGE FLAME Press OFF to complete the program Setting the Timer Select Timer mode by briefly pressing the SET button Press and hold the SET button until the P1 is displayed and the time flashes Set the hour by pre...

Страница 27: ...27 NOTES ...

Страница 28: ...28 rev 141125 EUROPEAN HOME a division of Europa Ja Inc 376 Washington Street Suite 203 Malden MA 02148 www europeanhome com ...