COOL WALL INSTALLATION GUIDE - DIRECT VENT
Element4 Gas Fireplaces
European
Home
.com
4
The outer “finishing wall” (minimum
thickness 1/2”) creates the air gap
between the two walls.
Element4 requires a minimum 20” vertical
vent before any offset of the vent pipe.
Cross Section
The inner wall should have a minimum
depth of 1”.
Method 4: Double Front Wall
Please Note:
Some electronics manufacturers specify that their products should not be installed on, near or above a heat source.
Consult your manufacturer’s specifications.
Mounting an electronic device is ultimately the owner’s decision and responsibility. European Home will not be held liable for any
adverse effects of heat on electronic devices located near a European Home fireplace.
*Use this method if you would like to
bring combustible finishing (such as wood
veneer or wallpaper) to the edge of the
fireplace face.
20”
≥ 1”
Call our Technical Team if you have any Questions:
781-324-8383 x. 502
≥ 10”
Inlet for air cavity.