Warranty

The Warranty

The Company warrants the European Home Gas Appliance to be free from defects in materials and workmanship at the time of manufacture. On the European Home Gas Appliance, there is a 
ten-year warranty on the firebox and its components, a five-year warranty on the main burner and pilot burner, and a one-year warranty on the gas control valve and fibre logs. Glass, plated/
painted finishes, and refractory lining are exempt.

Remedy And Exclusions

The coverage of this Warranty is limited to all components of the Gas Appliance manufactured by The Company.
This Warranty only covers European Home Gas Appliances installed in the United States or Canada.
If the components of the Gas Appliance covered by this Warranty are found to be defective within the time frame stated (see The Company's right of investigation outlined below). The Company 
will, at its option, replace or repair defective components of the Gas Appliance manufactured by The Company at no charge, and will also pay for reasonable labor costs incurred in replacing or 
repairing components. If repair or replacement is not commercially practical, The Company will, at its option, refund the purchase price of the European Home Gas Appliance. 
This Warranty covers only parts and labor as provided above. In no case shall The Company be responsible for materials, components, or construction which are not manufactured or supplied by The 
Company, or for the labor necessary to install, repair or remove such materials, components or construction. All replacement or repair components will be shipped F.O.B. the nearest Company factory. 

Qualifications To The Warranty

The Gas Appliance Warranty outlined above is further subject to the following qualifications:
(1)  The Gas Appliance must be installed in accordance with The Company installation instructions and local building codes. The Warranty on this European Home Gas Appliance covers only 

the component parts manufactured by The Company. The use of components manufactured by others with this European Home Gas Appliance could create serious safety hazards, may 
result in the denial of certification by recognized national safety agencies, and could be in violation of local building codes. This warranty does not cover any damages occurring from the 
use of any components not manufactured or supplied by The Company

(2)  The European Home Gas Appliance must be subjected to normal use. The Gas Appliances are designed to burn gas only. Burning conventional fireplace fuels such as wood, coal or any 

other solid fuel will cause damage to the Gas Appliance, will produce excessive temperatures and will result in a fire hazard.

Limitations On Liability

It is expressly agreed and understood that The Company sole obligation, and purchaser's exclusive remedy under this Warranty, under any other warranty, expressed or implied, or in contract, 
tort or otherwise, shall be limited to replacement, repair, or refund, as specified above.
In no event shall The Company be responsible for any incidental or consequential damages caused by defects in its products, whether such damage occurs or is discovered before or after 
replacement or repair, and whether or not such damage is caused by Company negligence. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the 
above limitation or exclusion may not apply to you. The duration of any implied warranty with respect to this European Home Gas Appliance is limited to the duration of the foregoing warranty. 
Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.

Investigation Of Claims Against Warranty

The Company reserves the right to investigate any and all claims against this Warranty and to decide upon method of settlement.

The Company Is Not Responsible For Work Done Without Written Consent

The Company shall in no event be responsible for any warranty work done without first obtaining The Company's written consent.

Dealers Have No Authority To Alter This Warranty

The Company employees and dealers have no authority to make any warranties nor to authorize any remedies in addition to or inconsistent with those stated above.

How To Register A Claim Against Warranty

In order for any claim under this Warranty to be valid, The Company must be notified of the claimed defect in writing or by telephone, as soon as reasonably possible after the defect is discovered. 
Claims against this Warranty in writing should include the date of installation, and a description of the defect.

Other Rights

This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state.

NOTE:

 

The Company,

 as stated above, refers to European Home, a division of Europa Ja, Inc.

The Company reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

Содержание DV 38 ST

Страница 1: ...efer to this manual For assistance or additional information consult a qualifiedinstaller serviceagencyorthe gassupplier Warning What to do if you smell gas Donottrytolightanyappliance Donottouchanyelectricalswitch do notuseanyphoneinyourbuilding Immediatelycallyourgassupplierfrom aneighbor sphone Followthegas supplier sinstructions Ifyoucannotreachyourgassupplier callthefiredepartment Installer L...

Страница 2: ...f reliable use Welcome to the European Home family of gas fireplace products Safety Alert Key DANGER Indicates a hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a hazardous situation which if not avoided could result in death or serious injury CAUTION Indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTI...

Страница 3: ...ust be grounded in accordance with local codes or in the absence of localcodes withtheNationalElectricalCode ANSI NFPA70 1987 WithintheState of Massachusetts this fireplace must comply with NFPA 54 Chapter 10 CAUTION Duetoitshighoperatingtemperatures theapplianceshouldbelocated out of traffic and away from furniture and draperies Children and adults should be alerted to the hazards of the high sur...

Страница 4: ...aceopening mustnotprojectbeyondthe shaded area shown in Figure25 For protection against freezing temperatures it is recommended that outer walls of thechasebeinsulatedwithavaporbarrier Thiswillreducethepossibilityofacold air convection current on the fireplace Figure 1 Fireplacedimensions Clearance from top of the Fireplace to a combustible ceiling within the fireplace enclosure Refer to Pages 10 ...

Страница 5: ...llation Requirements Q Q DV38STmodelfireplacesarecertifiedforusewithEuropeanHomeventingcomponents 5 8 Q Q Minimum clearance to combustible construction around the vent pipe is 1 on all sides except on horizontal venting where the top of the pipe must have a clear anceofatleast2 Q Q UseonlycertifiedEuropeanHomeventcomponents Theuseofotherpartswillvoidthe EuropeanHomewarranty andmayimpedetheoperatio...

Страница 6: ...eatprotectionatthetopofthe termination where temperatures are highest 2 Attach to the faceplate of the termination using four sheet metal screws 3 If installing the termination over vinyl siding use theVSSTermination Shield Installing Heat Guards overTerminations Figure 6c InstallingtheNailingFlangeExtension Figure 6 InstallingtheVSSVinylShield Figure 5a InstallingaPTOtermination Figure 5b Install...

Страница 7: ... 8 Retractedinstallationusingacombinationofsolidandflexventing Use theventgraphtodetermineyourallowablerunthenselectappropriate components RHS8 Figure 8a RHS8 Installation Install by sliding over vent pipe where it passes through thecombustibleconstruction Figure8b RHS101Installation Installbyslidingoverventpipewhereitpassesthrough thecombustibleconstruction Framing Drywall RHS101 Heat Shield Inne...

Страница 8: ...heightis32feetabovefireplace Notethattheflamecharacteristics will change if the maximum vent height is used Minimumclearances2 fromventtoallcombustiblematerialsmustbemaintained A maximum of two offsets each offset has two 90 bends may be made and shallnotexceedtotallengthof25 oftheverticalventheightwhenmeasured center to center of venting Example Typical vent installation 20 vertical vent 2 2 offs...

Страница 9: ...on Horizontal Vent Installation Vent systems that terminate through a wall may be comprised of up to seven dif ferent component types Short Configurations For installations straight through the wall use an PTO 4 4F termination and PXT 5 or PXT 10 to achieve the desired length The maximum horizontal vent run with no vertical lift is 12 See Figures14and15 Figure 14 Shorthorizontalinstallation Heat S...

Страница 10: ...gure13 Figure 16 Extendedhorizontalinstallationusingacombinationofrigidandflex venting Figure 15 RHS101HeatShieldforshorthorizontalinstallation Installbyslidingover theventpipewhereitconnectstothetermination Installation RHS8 Figure 17a Verticalventingwith1offset 1offset two90 bends Minimum clearance to combustible construction around the vent pipe is 1 on all sides must be maintained except on ho...

Страница 11: ...al power vent module EDVRSPV47 exterior vertical roof mount 4 7 stainless steel power vent system EDVWSPV47 exterior horizontal wall mount 4 7 stainless steel power vent system Figure 24 Combustiblemantlesandfacings BothSidesTypical Horizontal Run in Fireplace Facing When selecting the finish material for your fireplace it is important to remember the following THE OPENING MUST NOT BE OBSTRUCTED I...

Страница 12: ...ion be given to the effects of elevated manteltemperatureswhichmaybeinexcessofproductdesign forexample candles plasticorpictures Thiscancausemelting deformation discoloration or premature failure ofT V and radio components Painting TheMasterPaintersandDecoratorsAssociationrecommendspecialcarewhenpainting thefireplacesurrounds Aqualityalkydsealershouldbeappliedpriortotheapplication of latex paints ...

Страница 13: ...reverse order Finger Holes Remove the Horizontal Access Panel To install the door hook the top edge of the door frame into place Lower the door into position and follow the previous steps shown in reverse order Installing the Doors 2 Step5 Ensure the tool is firmly in the lower end of the slot as shown Then pull toward you CAUTION hold the tool securely 3 Step6 Pull hard if necessary to release th...

Страница 14: ...f Gas To Appliance 3 Push in gas control knob slightly and turn clockwise to Off Do not force 4 Replace the lower horizontal access panel 1 Turn off remote switch 2 Lift out the lower horizontal access panel 1 STOP Read the safety information above on this label 2 Lift out the lower horizontal access panel 3 Push in gas control knob and turn clockwise to OFF 4 Wait five 5 minutes to clear out any ...

Страница 15: ...n your building Immediately call your gas supplier from a neighbor s phone Fol low the gas supplier s instructions If you cannot reach your gas supplier call the Fire Department C Use only your hand to push in or turn the gas control knob Never use 1 STOP Read the safety information above on this label 2 Remove the lower horizontal access panel 3 Turn Incoming gas valve to the ON position 4 Wait 5...

Страница 16: ...ou to raise or lower the flames To adjust the flames locate the black knob marked Hi Lo in the center of the gas control valve See Figure 32 Q Q To raise the flame height turn the black knob located behind the lower trim counter clockwise Q Q To lower the flame height turn clockwise Figure 32 Hi Lo AdjustmentontheDV38STgasvalve Cleaning When the fireplace is first activated there may be some smoki...

Страница 17: ...ocate pilot adjustement screw on gas control valve Flame is decreased by turn ing adjustment screw clockwise Pilot won t ignite Disconnect remote wires and try to light pilot If pilot now works remote connections are faulty Check wiring diagram figure33 Main burner will 1 Check wiring seefigure33 not light 2 Check wall switch for proper connection If your fireplace still does not operate correctly...

Страница 18: ...ntenance DV 38 ST Spare Parts DV 38 ST DV 38 ST E NG Gas Valve RGC1006 RGC1004 NG Pilot RPA020 RPA003 NG Burner RBL38501 RGC1003 LP Gas Valve RGC1005 LP Pilot RPA021 RPA004 LP Burner RBL38502 Orifice ROR1153 ROR1153 Door RDTL42 RDTL42 Base RLG550 RLG550 ...

Страница 19: ...mpany 2 The European Home Gas Appliance must be subjected to normal use The Gas Appliances are designed to burn gas only Burning conventional fireplace fuels such as wood coal or any other solid fuel will cause damage to the Gas Appliance will produce excessive temperatures and will result in a fire hazard Limitations On Liability It is expressly agreed and understood thatThe Company sole obligati...

Страница 20: ...lairsupplyinlettobuildingorthecombustionairinlettoany otherappliance 16inches 41cm minimumforappliances 100000BTU H 30kW M clearancetomechanicalairsupplyinlet 6feet 1 8m minimum N clearanceabovepavedsidewalkorapaveddrivewaylocatedonpublicproperty 7feet 2 1m minimum P c l e a r a n c e u n d e r v e r a n d a p o r c h d e c k o r b a l c o n y 1 6 i n c h e s 4 1 c m m i n i m u m t o n o n c o m ...

Страница 21: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GASVENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspectio...

Страница 22: ...EUROPEAN HOME a division of Europa Ja Inc 376 Washington St Suite 203 Malden MA 02148 tel 781 324 8383 fax 781 324 8384 www europeanhome com ...

Отзывы: