Page
|
9
Number 23/24 – Temp sensor hot water recirculation
There
are
different
ways
to
control
hot
water
recirculation
directly
from
Exotrol
Multi
.
One
way
is
to
measure
the
temperature
on
the
domestic
hot
water
pipe
and
thereby
decide
when
the
circulation
pump
needs
to
operate.
If
using
this
method
the
sensor
must
be
installed.
Place
the
sensor
on
the
hot
water
recirculation
return
pipe
at
least
1m
from
tank
2
(or
electric
boiler).
Insulate
well.
Number 25/26 – Temp sensor solar panel system 1
Not
implemented
Number 27/28 – Temp sensor solar panel system 2
Not
implemented
Number 29/30 – Temp sensor extra 1
Not
used
Number 31/32 – Temp sensor heating system flow pipe
Not
implemented
Number 33/34 – Temp sensor heating system return pipe
Not
implemented
Number 35/36 – Temp sensor domestic hot water
Not
implemented
Number 37/38 – Temp sensor domestic cold water
Not
implemented
Number 39/40/41 – External error relay
This
block
can
be
used
if
a
signal
to
another
control
system
is
needed.
The
signal
can
be
both
NC
or
NO.
At
normal
operation
without
errors
39
and
40
is
closed.
If
error
occurs
(or
power
failure)
contact
between
40
and
41
will
be
true.