The eyepieces can be equipped with optional rubber eyeshades. They prevent damage to the eyepiece and prevent 
stray light. The eyeshade can simply be slipped over the eyepiece  
Connecting the power adapter   
 
The MicroBlue series supports a wide range of operating voltages: from 100 to 240V. Please use a grounded power 
connection  
 

1.

 

Make sure the power switch is off before connecting  

2.

 

Insert the connector of power cord into the MicroBlue power socket, and make sure it connects well  

3.

 

Insert the other connector of the adapter into the mains socket, and make sure it connects well 

  
D

Doo  nnoott  bbeenndd  oorr  ttw

wiisstt  tthhee  ppoow

weerr  ccoorrdd,,

 it will be damaged. Use the power cord that is supplied by Euromex. If it is lost or 

damaged, choose one with the same specifications 

Operation  

Setting up the illumination:  

For optimal contrast and resolution one should follow the 
procedure below:  

A.

 

Place a specimen on the object stage and focus, using the 
4x objective, with a fully opened iris diaphragm  

B.

 

Turn light intensity to lowest position, then look through 
the eyepiece(s) and turn up to the comfortable light 
intensity level  

C.

 

Turn the condenser in the highest position  

D.

 

Close the iris diaphragm, until it is just visible on the edge 
of the field of view 

 
The microscope is properly set for use with the 4x objective. For 
each other magnification in bright field use, this procedure should be repeated to ensure the best balance between 
contrast and resolution 

 

CCaauuttiioonn

:  

The maximum light intensity when using the 4x and 10x can damage the eyes!

 

 

 

Place the specimen slide 

On the MB.1001 the slide is placed beneath the object clips. On the other models into the clamp of the mechanical 
stage and can be carefully moved into X- and Y- directions (M) 

1.

 

Push the arm of the specimen holder backwards 

2.

 

Release the arm slowly clamping the slide with the cover glass facing up 

3.

 

Rotating the X and Y-axis knob will move the specimen to the center for alignment with the center of the 
objective 

Focusing and slide protection  

1.

 

Select the 4x objective and make sure that it is placed correctly in the optical path  

2.

 

Rotate the coarse adjustment knob to top, observe 
the right eyepiece with your right eye. Rotate the 
coarse focusing knob until the image appears 

3.

 

Rotate the fine focusing knob to sharpen the image 

4.

 

When you perform focusing with a S100x objective, 
you need to lock the slide protection screw (D). The 
slide protection screw protects the slide by limiting 
the travel range of the mechanical stage. This way 
the objectives will not touch or break your slides. In 
case a standard version is purchased, including a 
S100x objective, this is pre-set at the factory 

Eyepieces  

A binocular (or trinocular) tube is less tiring for the eyes compared to a monocular tube. In order to obtain a smooth 
“compound” image, we recommend you to go through the steps below 

1. The interpupillary distance  

The correct interpupillary distance is reached when one round image is seen in the field of view (see image below). This 
distance can be set by either moving the tubes towards each other or moving them away from each other. This distance 
is different for each observer and thus should be set individually. When more users are working with the microscope it 
is recommended to remember your interpupillary distance for a quick set-up during new microscopy sessions 

 
 
 
 
  
 
 

 
 
 

 
2. The correct eye point  

The eye point is the distance from the eyepiece to the user’s pupil. To obtain the correct eye point, move the eyes 
towards the eyepieces until a sharp image is reached at a full field of view 

Field of view before 

adjustment 

 
 

Field of view after 

adjustment 

 
 

9

Содержание BlueLine Series

Страница 1: ...D U T C H Q U A L I T Y MicroBlue BlueLine series user manual...

Страница 2: ...e ratio Please read this manual carefully before using this product to ensure correct and safe usage The contents of this manual are subject to change without notice The appearance of the actual produ...

Страница 3: ...de protection 9 Eyepieces 9 1 The interpupillary distance 9 2 The correct eye point 9 3 Adjusting the diopter 10 Abbe condenser 10 Use of the S100x oil immersion objective 10 Safety device 11 Illumina...

Страница 4: ...e of the lens regularly Cleaning optical components is a delicate matter Please read the cleaning instructions in this manual carefully E En nv vi ir ro on nm me en nt t s st to or ra ag ge e a an nd...

Страница 5: ...widefield eyepieces WF10x H and Achromatic objectives as mentioned below table P Pl le ea as se e n no ot te e On www euromex com you can find the latest updates about MicroBlue models and accessories...

Страница 6: ...E Tension adjustment M Object stages mechanical stage or clips F On Off switch not visible N Height adjustment lever condenser G Light intensity control O Condenser with irisdiaphragm filterholder H...

Страница 7: ...es into the objective nosepiece from the lowest magnification to the highest in a clockwise direction from the rear side of the microscope When using the microscope start using the low magnification o...

Страница 8: ...co or rd d it will be damaged Use the power cord that is supplied by Euromex If it is lost or damaged choose one with the same specifications Operation Setting up the illumination For optimal contras...

Страница 9: ...e mechanical stage This way the objectives will not touch or break your slides In case a standard version is purchased including a S100x objective this is pre set at the factory Eyepieces A binocular...

Страница 10: ...rews using an allen key and move the image of the condenser ring to the center of the field of view F Open the diaphragm gradually G The condenser is centered correctly if the image remains in the cen...

Страница 11: ...scope with power supply disconnected to keep the batteries in good working condition and recharge after batteries run empty The illumination has the following specifications LED NeoLED 1W 300 mA monoc...

Страница 12: ...earings that are not dust sensitive With a drop of sewing machine oil you can lubricate the bearing Changing the batteries of the MicroBlue C Ca au ut ti io on n Always remove the power cable from the...

Страница 13: ...esigned to be used on the photo port of the microscope head It is also possible to use the digital camera in combination with a monocular or binocular head Simply remove the eyepiece and place the cam...

Страница 14: ...re parts For current accessories and spares please check our website www euromex com Trinocular MicroBlue head with mounted camera in photo port Monocular MicroBlue microscope with camera replacing th...

Страница 15: ...15 Notes 15...

Страница 16: ...bv Papenkamp 20 6836 BD Arnhem The Netherlands T 31 0 26 323 22 11 info euromex com www euromex com Management System ISO 9001 2015 www tuv com ID 0000037140 All information may be changed without pr...

Отзывы: