Problem

Possible cause and solution

The appliance does 
not switch on.

Power is not properly supplied — make sure the 
appliance is properly connected to your power supply 
and your electrical outlet is working.
The electrical outlet is faulty — check whether the unit 
is working if connected to a different power outlet.
The appliance is not switched on — ensure you have 
pressed the POWER button to switch on the appliance.

The appliance 
makes a loud noise.

The air purifier is located on an inclined surface — 
place the unit on a level surface.
The filter is clogged — check all filters and clean or 
replace them as necessary.
The air inlet is blocked — check and ensure that the air 
inlet and outlets are free of obstructions.

Poor air purifying 
effect, especially 
with regard to 
odours.

The filters are installed incorrectly — refer to page 12

 

for correct filter installation instructions.
The filters may have reached the end of their lifespan 
— replace the filters.

An unpleasant 
odour is coming 
from the machine.

The filters needs to be changed — replace the filters 
according to the instructions.

There is a burnt 
smell and/or smoke 
coming from the 
unit.

The unit is faulty — switch off and unplug the unit, then 
contact our after sales support centre.
The filter parts are still in the original packaging — refer 
to page 12 for correct filter installation instructions.

The filter indicator 
does not turn off.

You may not have reset the counter — press the 
FILTER RESET button to reset the counter.

The unit got wet 
and now works 
abnormally.

The unit is damaged — switch off and unplug the unit, 
then contact our after sales support centre.

If you experience problems with your air purifier, or it appears not to be 
operating correctly, check the information below for solutions to common 
problems. If you still cannot solve your problem, please contact our after sales 
support centre for advice.

 

Do not attempt to repair the appliance yourself.

FAQs & Troubleshooting Guide

Содержание APCSM25

Страница 1: ...Model Number APCSM25 INSTRUCTION MANUAL Air Purifier AFTER SALES SUPPORT AU 1300 886 649 NZ 0800 836 761...

Страница 2: ...es Support AU 1300 886 649 NZ 0800 836 761 info tempo org 03 General Safety Instructions 06 Product Overview 08 Getting Started 09 Instructions 11 FAQs Troubleshooting Guide 12 Other Useful Informatio...

Страница 3: ...er or other liquid never spill liquids into it Do not place or store it where it can fall or be pulled into a tub or basin If it accidentally has fallen into water do not reach into the water Immediat...

Страница 4: ...in domestic environments It is not suitable for commercial industrial or trade use Do not use it for any other purpose and only use it as described in this manual Common sense These instructions are n...

Страница 5: ...he air purifier always turn it off first and disconnect the power supply and then move it slowly Keep the unit upward during transport and storage Misuse We accept no responsibility for any eventual i...

Страница 6: ...from the product purchased All images in this manual are for reference purposes only Parts are not necessarily pictured to scale 1 Control panel 2 Housing 3 Air intake 4 Base with air quality light i...

Страница 7: ...36 761 info tempo org Control panel Product Overview Cont Touch buttons 1 2 3 4 5 POWER ON STANDBY Press SPEED to select the speed from AUTO SLEEP LOW HIGH Press TIMER to select the off timer from 1 h...

Страница 8: ...ice Documentation Make sure you have read and understood all instructions and warnings in this manual Refer the Product Overview to identify all parts of the appliance and familiarise yourself with it...

Страница 9: ...nit is running press the POWER button to switch the machine to standby mode Fan speed Press the SPEED button to select the fan speed options AUTO SLEEP LOW HIGH Auto mode In AUTO mode the air purifier...

Страница 10: ...h it on again When the filter indicator has counted a total of 2000 hours the FILTER RESET indicator will start flashing to alert you to clean or replace the filters Please refer to page 12 for instru...

Страница 11: ...orrect filter installation instructions The filters may have reached the end of their lifespan replace the filters An unpleasant odour is coming from the machine The filters needs to be changed replac...

Страница 12: ...maintain the unit in good working order When the FILTER RESET indicator flashes it is time to clean or replace the filters 1 Tilt the unit and rotate the base in anticlockwise direction until it canno...

Страница 13: ...ance Our after sales support centre stocks spare filters for the air purifier To purchase a filter set call the centre on 1300 886 649 or email us at info tempo org Other Useful Information Cont Techn...

Страница 14: ...rical and electronic products contain substances that can have a detrimental effect on the environment and human health if disposed of inappropriately Observe any local regulations regarding the dispo...

Страница 15: ...15 After Sales Support AU 1300 886 649 NZ 0800 836 761 info tempo org...

Страница 16: ...s with this product or if it fails to perform to your expectations make sure to contact our After Sales Support Centre on AU 1300 886 649 or NZ 0800 836 761 for advice Distributed by Tempo Aust Pty Lt...

Отзывы: